Miller Electric Auto-Axcess 450 manual California Proposition 65 Warnings

Page 37

FALLING UNIT can cause injury.

DUse lifting eye to lift unit only, NOT running gear, gas cylinders, or any other accessories.

DUse equipment of adequate capacity to lift and support unit.

DIf using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.

MOVING PARTS can cause injury.

DKeep away from moving parts such as fans.

DKeep away from pinch points such as drive rolls.

DHave only qualified persons remove doors, panels, covers, or guards for maintenance as necessary.

DKeep hands, hair, loose clothing, and tools away from moving parts.

DReinstall doors, panels, covers, or guards when maintenance is finished and before re- connecting input power.

MAGNETIC FIELDS can affect Implanted Medical Devices.

DWearers of Pacemakers and other Implanted Medical Devices should keep away from serv- icing areas until consulting their doctor and the device manufacturer.

OVERUSE can cause OVERHEATING.

DAllow cooling period; follow rated duty cycle.

DReduce current or reduce duty cycle before starting to weld again.

DDo not block or filter airflow to unit.

H.F. RADIATION can cause interference.

DHigh-frequency (H.F.) can interfere with radio navigation, safety services, computers, and communications equipment.

DHave only qualified persons familiar with electronic equipment install, test, and service H.F. producing units.

DThe user is responsible for having a qualified electrician prompt- ly correct any interference problem resulting from the installa- tion.

DIf notified by the FCC about interference, stop using the equipment at once.

DHave the installation regularly checked and maintained.

DKeep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.

READ INSTRUCTIONS.

D Use Testing Booklet (Part No. 150 853) when servicing this unit.

DConsult the Owner’s Manual for welding safety

precautions.

DUse only genuine replacement parts from the manufacturer.

6-3. California Proposition 65 Warnings

Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)

Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

For Gasoline Engines:

Engine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproduc- tive harm.

For Diesel Engines:

Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.

6-4. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them, or using a cable cover.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from opera- tor as practical.

5.Connect work clamp to workpiece as close to the weld as possi- ble.

About Implanted Medical Devices:

Implanted Medical Device wearers should consult their doctor and the device manufacturer before performing or going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations. If cleared by your doctor, then following the above procedures is recom- mended.

OM-210 540 Page 33

Image 37
Contents Processes OM-210 540SDescription File Advanced Manufacturing SystemsFrom Miller to You Table of Contents Troubleshooting − TroubleshootingArc Welding Hazards Symbol UsageElectric Shock can kill HOT Parts can cause severe burnsARC Rays can burn eyes and skin Fumes and Gases can be hazardousWelding can cause fire or explosion Flying Metal or Dirt can injure eyesFire or Explosion hazard Welding Wire can cause injuryFalling Unit can cause injury Moving Parts can cause injuryCalifornia Proposition 65 Warnings Principal Safety StandardsEMF Information About Implanted Medical DevicesUNE Décharge Électrique peut entraîner la mort Symboles utilisésLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LES Bouteilles peuvent exploser si elles sont endommagées LE Bruit peut endommager l’ouïeRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesserLES Fils DE Soudage peuvent provoquer des blessures Proposition californienne 65 AvertissementsLE Soudage À L’ARC risque de provoquer des interférences Information EMF Principales normes de sécuritéEn ce qui concerne les implants médicaux OM-210 540 Specifications − InstallationDimensions And Weight 17-3/32 in 434 mm 17-3/8 in 441 mm 19-3/32 in 485 mmVolt-Ampere Curves Duty Cycle And Overheating100% Duty Cycle At 450 Amperes OverheatingSelecting a Location Connection DiagramDo not stack units. Beware of tipping Positive + Weld CableRear Panel Receptacles And Supplementary Protectors Incorrect Installation Connecting To Weld TerminalsSelecting Weld Cable Sizes Function Socket Socket Information Peripheral Receptacle FunctionsMotor Control Receptacle Functions Hz Three Phase Input Voltage Electrical Service Guide230 400 460 575 136 263 228 356Welding Power Source Input Power Connections Connecting Input PowerDisconnect Device Input Power Connections Touch Sensor Operation Remote Program SettingRemote Program Select Program No Output a Output B Output COperational Terms − OperationWeld StartCrater PostflowFront Panel Controls See Section Wire Type LEDProcess LED Gas Type LEDSTL Robot Abbreviations Front Panel SwitchesManufacturer Robot Abbreviation Xxxx Robot TypeSchedule Robot Calibration Mode100 IPM 1000 IPM Actual Motoman Welder Condition File Robot Auto-Calibration Sample ProgramsSample Auto-Calibration Routine For Motoman Robot Sample Auto-Calibration Routine For ABB Robot Sample Auto-Calibration Routine For Fanuc RobotWeld Data Pulse Reset ModeMild Steel Accu-pulseRoutine Maintenance − MaintenanceBlowing Out Inside Of Unit Shock Hazard from testing − Safety Precautions for ServicingServicing Hazards Exploding Parts can cause injuryCalifornia Proposition 65 Warnings Set Value Mode − TroubleshootingDiagnostics Indicates a CRC PCM bus error Command errorIndicates a UIM Indicates RMD demo is doneIndicates a trigger closed error Indicates a contactor on errorRemoving Cover and Measuring Input Capacitor Voltage Diagnostic LED’s On Process Control Module PC4 Process Control Module PC4 Diagnostic LED’sProcess Control Module PC4 Status DiagnosisDiagnostic LED’s On Wire Feed Module PC6 Diagnostic LED’s On User Interface Module PC7 User Interface Module PC7 Diagnostic LED’sLED33 Automation Interface Module PC9 Diagnostic LED’sLED32 Diagnostic LED’s On Automation Interface Module PC9 Input signal off from relay K6 for no arc detected Input signal on from relay K6 for arc detectedInput signal on for aux. relay energized Input signal off for aux. relay energizedModule Status LED’s Network And Module Status LED’s Network Status LED’sRed Circuit board is operating normallyTrouble Remedy TroubleshootingOM-210 540 Circuit Diagram For Welding Power Source Part 1 − Electrical Diagrams207 903-G Part 1 Circuit Diagram For Welding Power Source Part 2 207 903-G Part 2 Circuit Diagram For 72 Pin Robot Interface 219 266-C Circuit Diagram For Peripheral/Motor Interface 219 267-B 16 − Fig − Parts ListWindtunnel Assembly LH And RH Windtunnel Assembly LH And RH -1Item Top Tray Assembly Rear Panel Assembly Front Panel Assembly -1Item Front Panel AssemblyDia Part Your distributor also gives ServiceSupport Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s