Miller Electric 301 G, DC, Trailblazer DC Engine Prestart Checks Robin EH64-Powered Units, Oil

Page 20

5-2. Engine Prestart Checks (Robin EH64-Powered Units)

Full

Check all fluids daily. Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil.

. Follow run-in procedure in en- gine manual.

. This unit has a low oil pressure shutdown switch. However, some conditions may cause en- gine damage before the engine shuts down. Check oil level often and do not use the oil pressure shutdown system to monitor oil level.

Fuel

Add fresh fuel before starting engine the first time (see maintenance label for specifications). Always leave filler neck empty to allow room for expan- sion. Check fuel level on a cold en- gine before use each day.

Oil

After fueling, check oil with unit on level surface. If oil is not up to full mark on dipstick, add oil (see mainte- nance label).

. To improve cold weather starting:

Keep battery in good condition.

Store battery in warm area.

Use correct grade oil for cold weather.

Oil Check

Oil Fill

Full

Gasoline

803 098 / 800 392-J

OM-4407 Page 16

Image 20
Contents Description OM-4407203 236UProcesses From Miller to You Table of Contents Options and Accessories Warranty Symbol Usage Arc Welding HazardsEngine Hazards Compressed Air Hazards Principal Safety Standards California Proposition 65 WarningsEMF Information Radiation can cause interferenceSignification des symboles − Consignes DE Sécurité − Lire Avant UtilisationUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in- cendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peut DES Organes Mobiles peuvent provoquer des blessuresLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoquer des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiquesSymbol Definitions − DefinitionsDimensions, Weights, and Operating Angles − SpecificationsWeld, Power, And Engine Specifications Fuel Consumption While Using Generator Power Fuel Consumption While WeldingGenerator Power Curve Exceeding duty cycle can damage unit and void warrantyDuty Cycle 100% Duty Cycle at 280 Amperes DC Stick And MIG Mode Volt-Ampere Curves CC/AC Stick Mode CC/DC Stick Mode CV/DC MIG ModeCC/DC TIG Mode TIG Mode Volt-Ampere CurvesCC/AC TIG Mode − Installation Installing Welding GeneratorOil Check Oil Fill Engine Prestart Checks Robin EH64-Powered UnitsOil Engine Prestart Checks Kohler-Powered Units Follow run-in procedure in engine manualActivating The Dry Charge Battery If Applicable Do not overfill battery cellsRead and follow all instruc ChargerConnecting The Battery Installing Exhaust Pipe+ − Connect negative − cable lastConnecting To Weld Output Terminals Stop engineAC/DC Models DC Only ModelsSelecting Weld Cable Sizes Remote Receptacle InformationAdjusting Wire MIG Weld Puddle Consistency For wetter weld puddle for mild steelFront Panel Controls Do not switch under load− Operating Welding Generator Switch Setting Process Output On/Off Control Process/Contactor Switch On CC/CV ModelsProcess/Contactor Switch Settings Set Adjust Remote Control Switch Stick Welding Only Remote Amperage/Voltage ControlGenerator Power Receptacles And Circuit Breakers − Operating Auxiliary EquipmentGfci Receptacle Option Optional Generator Power ReceptaclesIf unit does not have Gfci re Ceptacles, use Gfci Current Available in Amperes 240 Receptacle− Maintenance Robin EH64-POWERED Units Maintenance Label Robin EH64-Powered UnitsRoutine Maintenance Robin EH64-Powered Units Every 8 hEvery 20 h Every 25 h Every 50 hEvery 1000 h Every 200 hEvery 500 h Servicing Air Cleaner Robin EH64-Powered Units Servicing Optional Spark Arrestor Robin EH64-Powered UnitsOverload Protection Robin EH64-Powered Units Tools NeededClose valve and valve cap Before adding oilRunning engine Tions as necessary, and wipe up fuelWeld/Power Speed Adjustment Adjusting Engine Speed Robin EH64-Powered UnitsIdle Speed Adjustment Stop engine before maintaining − Maintenance KOHLER-POWERED UnitsRoutine Maintenance Kohler-Powered Units Maintenance Label Kohler-Powered Units Servicing Air Cleaner Kohler-Powered Units Servicing Optional Spark Arrestor Kohler-Powered UnitsFull Tools Needed Adjusting Engine Speed Kohler-Powered Units Overload Protection Kohler-Powered Units Trouble Remedy − TroubleshootingWelding Troubleshooting Generator Power Troubleshooting Engine TroubleshootingIs on Work like a Pro − Electrical Diagrams 209 625-C OM-4407 209 620-B Grounding Generator To Truck Or Trailer Frame − Generator Power GuidelinesSelecting Equipment Grounding When Supplying Building Systems How Much Power Does Equipment Require?Earth ground if supplying Amperes x Volts = WattsApproximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Current Load Watts AmperesOM-4407 − Parts List Main Assembly Kohler Engine ShownMain Assembly Dia Part Description Quantity Mkgs 206537 Panel, Front w/Components Panel, Front w/Components -1Item Generator -1Item Page Page Service SupportOwner’s Record Miller Electric Mfg. Co