Schumacher SP3 owner manual Maintaining a Battery, Desulfation Mode, Aborted Charge

Page 12

NOTE: If the charger has to provide its maximum maintain current for a continuous 12 hour period, it will go into Abort Mode (see Aborted Charge section). This is usually caused by a drain on the battery, or the battery could be bad. Make sure there are no loads on the battery. If there are, remove them. If there are none, have the battery checked or replaced.

Maintaining a Battery

The SP3 is a battery charger/maintainer that maintains both 6 and 12 volt batteries, keeping them at full charge. It can charge small batteries and maintain both small and large batteries. If you are maintaining a fully charged large battery, you are properly utilizing the battery charger. However, if you were to use this battery charger to charge a large battery, such as a marine deep cycle battery, that was not fully charged, you may lose some of the battery’s capacity. This would cause the large battery to be unable to hold a charge and become useless. Therefore, we do not recommend charging a large battery with this unit.

NOTE: The maintain mode technology utilized in Schumacher chargers allows you to safely charge and maintain a healthy battery for extended periods of time. However, problems with the battery, electrical problems in the vehicle, improper connections or other unanticipated conditions could cause excessive current draws. As such, occasionally monitoring your battery and the charging process is recommended.

Desulfation Mode

If the battery is left discharged for an extended period of time, it could become sulfated and not accept a normal charge. If the charger detects a sulfated battery, the charger will switch to a special mode of operation designed for such batteries. If successful, normal charging will resume after the battery is desulfated. Desulfation could take up to 8 hours. If desulfation fails, charging will abort, the yellow LED will blink, and the display will show

“CHARGING ABORTED BAD BATTERY”.

Aborted Charge

If charging cannot be completed normally, charging will abort. When charging aborts, the charger’s output is shut off, the yellow LED will blink, and the display will show “CHARGING ABORTED BAD BATTERY”. To reset after an aborted charge, unplug the charger from the outlet, wait a few moments and plug it back in.

• 12 •

Image 12
Contents Model / Modelo SP3 Manual DEL UsuarioImportant Safety Instructions Save These Instructions Risk of Electric Shock or FireRisk of Explosive Gases Personal Precautions Risk of Explosive Gases Charger Location Risk of Explosion Contact with Battery Acid DC Connection Precautions Page Assembly Instructions FEATURES/CONTROL Panel Digital DisplayLED Display Operating InstructionsUsing the Quick-Connect Cable Connectors Amp Battery ClipsCharging Quick-Connect Cable with FuseBattery Connection Indicator Cord Set with 12V Cigarette AdapterMaintaining a Battery Desulfation ModeAborted Charge Charging Aborted BAD Battery Yellow LED blinking Maintenance InstructionsDisplay Messages Moving and Storage InstructionsTroubleshooting Problem Possible Cause REASON/SOLUTION Replacement PartsBefore Returning for Repairs For Repair or ReturnPage Do not Return this Product to the Store Year Limited Warranty Program Registration Producto EL Riesgo DE Descarga Eléctrica O Incendio Page Riesgo DE Gases Explosivos Precauciones Personales Riesgo DE Gases ExplosivosPage Page Precauciones DE Conexión EN CC Page Instrucciones DE Montaje CARACTERÍSTICAS/PANEL DE Control Pantalla digitalInstrucciones DE Operación Carga Pinzas De Bateria De 50 AmpsCable de Conexión rápida c/Fusible Indicador de conexión de la batería Manteniendo una bateríaModo de desulfatación Carga anuladaMuestra DE Mensajes Instrucciones DE Mantenimiento Instrucciones Para EL Manejo Y AlmacenamientoLocalización Y Solución DE Problemas Posible Causa Solutión RepuestosAntes DE Devolver a Reparaciones Page ¡NO LO Devuelva Este Producto a LA Tienda