Schumacher SP1 Automatic Charging Mode, Aborted Charge, Desulfation Mode, Completion of Charge

Page 12

2.Insert the 12V accessory plug into the 12V accessory outlet.

3.Route the power cord from the charger through the vehicle’s open window.

4.Plug the charger power cord into a grounded 120V AC electrical wall outlet.

Automatic Charging Mode

When an Automatic Charge is performed, the charger switches to the Maintain Mode (see below) automatically after the battery is charged. For a battery with a starting voltage under 0.2 volts, use a manual charger to pre-charge the battery for five minutes to get additional voltage into the battery.

Aborted Charge

If charging cannot be completed normally, charging will abort. When charging aborts, the charger’s output is shut off and the CHARGING LED will blink. To reset after an aborted charge, unplug the charger from the AC outlet, wait a few moments and plug it back in.

Desulfation Mode

Desulfation could take 8 to 10 hours. If desulfation fails, charging will abort and the CHARGING LED will blink.

Completion of Charge

Charge completion is indicated by the CHARGED LED. When lit, the charger has switched to the Maintain Mode of operation.

Maintain Mode (Float-Mode Monitoring)

When the CHARGED LED is lit, the charger has started Maintain Mode. In this mode, the charger keeps the battery fully charged by delivering a small current when necessary. If the charger has to provide its maximum maintain current for a continuous 12 hour period, it will go into Abort Mode (see Aborted Charge section). This is usually caused by a drain on the battery or the battery could be bad. Make sure there are no loads on the battery. If there are, remove them. If there are none, have the battery checked or replaced.

Maintaining a Battery

The Schumacher SP1 is a battery maintainer that maintains both

6 and 12 volt batteries, keeping them at full charge. It can charge small batteries and maintain both small and large batteries. If you are maintaining a fully charged large battery, you will be properly utilizing the battery charger. However, if you were to use this battery charger

•11•

Image 12
Contents Model / Modelo SP1 Page Risk of Electric Shock or Fire Personal Precautions Risk of Explosive Gases Risk of Explosive GasesPage DC Connection Precautions Page Page Grounding and ac power cord connections FeaturesAssembly Instructions AC PowerCharging Operating InstructionsUsing The Quick-Disconnect Cable Connectors Amp Battery ClipsPermanent Ring Connectors 12V Accessory PlugAutomatic Charging Mode Desulfation ModeMaintain Mode Float-Mode Monitoring Maintaining a BatteryMaintenance Instructions Calculating Charge TimeTroubleshooting Problem Possible Cause REASON/SOLUTION Moving and Storage InstructionsProblem Possible Cause REASON/SOLUTION Before Returning for Repairs Page Do not Return this Product to the Store Page Page Mail To Business Center DriveMount Prospect, IL Programa DE Registro DE 5-AÑOS DE Garantía Limitada Advertencia EL Riesgo DE Descarga Eléctrica O Incendio Riesgo DE Gases Explosivos Precauciones Personales Riesgo DE Gases ExplosivosPage Page Precauciones DE Conexión EN CC Page Page Conexiones a tierra y energía de CA Características Instrucciones DE MontajeLED Cargando LED CargadoInstrucciones DE Operación CargaPinzas De Bateria De 50 Amps Conectores Permanentes De Argolla Enchufe De 12 VoltsModo de carga automática Carga anuladaModo de desulfatación Finalización de la cargaModo de mantenimiento Monitoreo a modo de flote Manteniendo una batería13. Cálculo DE Tiempo DE Carga Instrucciones DE MantenimientoInstrucciones para el manejo y almacenamiento Localización Y Solución DE Problemas Posible Causa Problema Posible Causa Solución LED CargaAntes DE Devolver a Reparaciones Page Page LA Tienda