Schumacher SP1 Using The Quick-Disconnect Cable Connectors, Amp Battery Clips, 12V Accessory Plug

Page 11

NOTE: This charger is equipped with an auto-start feature. Current will not be supplied to the battery clips until a battery is properly connected. Meaning, the clips will not spark if touched together.

Using The Quick-Disconnect Cable Connectors

Connect any of the three output cable assemblies to the charger. Make sure to place the charger on a dry, non-flammable surface like metal or concrete.

NOTE: Never connect the clamp and ring terminal connectors together for use in other applications, such as external battery or other power source charging, or to extend the output cable length, as reverse polarity and/or overcharge conditions will occur.

50 Amp Battery Clips

1.Connect the end of the charger output cable to the end of the 50 Amp Battery clips cable.

2.Follow the steps in sections 6 and 7 to connect the output clips to the battery.

3.After a good electrical connection is made to the battery, plug the power cord into a grounded 120V AC electrical wall outlet.

Permanent Ring Connectors

1.To permanently attach to a battery, loosen and remove each nut from the bolt at the battery terminal.

2.Connect the red POSITIVE connector ring to the POSITIVE battery terminal.

3.Connect the black NEGATIVE connector ring to the NEGATIVE battery terminal.

4.Replace and tighten the nuts to secure.

5.Connect the cable to the end of the charger output cord. Take care to keep the wires and plug away from metal and moving parts.

6.Plug the charger power cord into a grounded 120V AC electrical wall outlet.

12V Accessory Plug

1.Connect the end of the 12V Accessory Plug Cable Quick- Connect to the charger.

•10•

Image 11
Contents Model / Modelo SP1 Page Risk of Electric Shock or Fire Risk of Explosive Gases Personal Precautions Risk of Explosive GasesPage DC Connection Precautions Page Page Features Grounding and ac power cord connectionsOperating Instructions Assembly InstructionsAC Power Charging12V Accessory Plug Using The Quick-Disconnect Cable ConnectorsAmp Battery Clips Permanent Ring ConnectorsMaintaining a Battery Automatic Charging ModeDesulfation Mode Maintain Mode Float-Mode MonitoringCalculating Charge Time Maintenance InstructionsMoving and Storage Instructions Troubleshooting Problem Possible Cause REASON/SOLUTIONProblem Possible Cause REASON/SOLUTION Before Returning for Repairs Page Do not Return this Product to the Store Page Page Mount Prospect, IL Mail ToBusiness Center Drive Programa DE Registro DE 5-AÑOS DE Garantía Limitada Advertencia EL Riesgo DE Descarga Eléctrica O Incendio Precauciones Personales Riesgo DE Gases Explosivos Riesgo DE Gases ExplosivosPage Page Precauciones DE Conexión EN CC Page Page Conexiones a tierra y energía de CA LED Cargado CaracterísticasInstrucciones DE Montaje LED CargandoPinzas De Bateria De 50 Amps Instrucciones DE OperaciónCarga Carga anulada Conectores Permanentes De ArgollaEnchufe De 12 Volts Modo de carga automáticaManteniendo una batería Modo de desulfataciónFinalización de la carga Modo de mantenimiento Monitoreo a modo de floteInstrucciones para el manejo y almacenamiento 13. Cálculo DE Tiempo DE CargaInstrucciones DE Mantenimiento Localización Y Solución DE Problemas Posible Causa LED Carga Problema Posible Causa SoluciónAntes DE Devolver a Reparaciones Page Page LA Tienda