SECTION 9: WIRING
SECTION 9: WIRING
WARNING
Electrical Shock Hazard
Disconnect electrical and gas supply before servicing.
This appliance must be connected to a properly grounded electrical source.
Failure to follow these instructions can result in death or electrical shock.
All heater models require constant 120 V/1Ø/ 60 Hz power supply. Check heater rating plate for electrical rating for proper circuit sizing. For servicing, a disconnect switch of proper electrical rating should be installed in the vicinity of the heater.
9.2 Low Voltage Thermostat with One Heater
All heaters are equipped with thermostat connections suitable to power a 24 V thermostat. Heater must be wired and electrically grounded in accordance with local codes. In the absence of local codes in accordance with: United States: refer to National Electrical Code® NFPA 70 - latest revision; Canada: refer to Canadian Electrical Code CSA C22.1 Part I - latest revision.
9.1 Positioning Thermostats
A room thermostat should be mounted on a
Avoid mounting thermostat on outside walls or in areas directly exposed to radiant heat or sunlight. Install wall tag in a visible location near thermostat. See Page 2, Section 2.1 for wall tag details.
24 Volt
Thermostat
Terminal
Strip
Gas | G |
|
| R |
|
Supply | W |
|
| ||
| C |
|
Electrical
Supply
R
W
19