Toshiba RAS-10SK-E Primary Judgement of Trouble Sources, Role of Indoor Unit Controller

Page 34

9-2. Primary Judgement of Trouble Sources

9-2-1. Role of Indoor Unit Controller

The indoor unit controller receives the operation com- mands from the remote control and assumes the fol- lowing functions.

Measurement of the draft air temperature of the indoor heat exchanger by using the thermo sen- sor (TA).

Louver motor control

Control of the indoor fan motor operation

Control of the LED display

Control of the outdoor unit compressor and the out- door fan motor.

9-2-2. Display of Abnormalities and Judgement of the Abnormal Spots

The indoor unit of this machine observes the opera- tion condition of the air conditioner and displays the contents of the self-diagnosis as block displays on the display panel of the indoor unit.

 

Table 9-2-1

 

 

 

 

Block display

Block display

 

 

 

A

OPERATION display flashing (1 Hz)

Power failure (when power is ON)

 

 

 

B

OPERATION display flashing (5 Hz)

Thermo sensor (TA) short/break

 

 

 

C

OPERATION display flashing (5 Hz)

Heat exchanger sensor (TC) short/break

 

 

 

D

OPERATION display flashing (5 Hz)

Indoor fan lock, abnormality of indoor fan

 

 

 

E

OPERATION display flashing (5 Hz)

Indoor PC board failure

 

 

 

F

OPERATION, TIMER and FAN-ONLY display

• Gas shortage, other refrigerant cycle trouble

 

flashing (5 Hz)

• Heat exchanger sensor open/break/short

 

 

• Overload relay trouble

 

 

 

(1)Judgement from defective operation or abnormal operation

Table 9-2-2

Symptom

Check

 

Primary judgement

 

 

 

 

No reaction on

Turn off the power once, turn it on

Remote control is

The indoor part (including the

remote control

again and try to operate the remote

not possible.

remote control) is defective.

operation

control again.

 

 

Remote control is

OK.

 

 

 

 

possible.

 

 

 

 

 

The outdoor fan

The compressor operates.

 

The outdoor part is defective.

does not rotate

 

 

(outdoor fan motor)

 

 

 

 

 

The compressor does not operate.

 

The inside part is defective.

 

 

 

 

– 34 –

Image 34
Contents R C O Contents What to be Prechecked First Troubleshooting FlowchartsPrimary Judgement of Trouble Sources Specifications RAS-10SK-E/10SA-E RAS-10SKX/10SAX CoolingCondition JIS C9612-1994 Temperature Cooling Construction Views Indoor UnitOutdoor Unit RAS-10SA-E RAS-10SAXWiring Diagram Main P.C. BoardSpecifications of Electrical Parts Parts name Type SpecificationsRefrigerant Cycle Diagram RAS-10SK-E / RAS-10SA-E RAS-10SKX / RAS-10SAXMICRO-COMPUTER Block Diagram AUTO, COOL, DRY, FAN onlyCool Operation Operation DescriptionsFAN only Operation M3/hDRY Operation Louver ControlAuto Operation Temporary AutoLow-Temperature Limit Control Cooling Operation ECONO. ModeCooling How to Set the Auto Restart Auto Restart FunctionHow to Cancel the Auto Restart Case of Power Failure during the Timer OperationInstallation Procedure Safety Cautions For general public useUK Plugs and Sockets etc Safety Regulations SI Number Installation Diagram of Indoor and Outdoor Units AttachInstallation Parts InstallationOptional Parts Remote control Installation placeCutting a Hole and Mounting Installation Plate Mounting the installation plateWhen the installation plate is directly mounted on the wall Electrical WorkHow to open the screw cap Wiring ConnectionHow to remove the front cabinet Taking out the power cordStripping length of connecting cable How to install the front cabinet on the indoor unitCase of downward piping Piping and Drain Hose InstallationCase of rightward piping Left-hand connection with pipingIndoor Unit Installation DrainageStrong wind Flaring Refrigerant Piping ConnectionVacuum Pumping Tightening connectionPacked Valve Handling Precautions A5 mm hexagon wrench is requiredOthers Auto Restart SettingHow to set the Auto Restart Gas Leak TestWhat to be Prechecked First Troubleshooting ChartPower Supply Voltage Incorrect Cable Connection between Indoor and Outdoor UnitsMisleading but Good Operations Program Controlled Operation Operation of air-conditioner DescriptionRole of Indoor Unit Controller Primary Judgement of Trouble SourcesBlock display Self-diagnosis with remote control Selecting ordinary modeSelf-diagnosis by check codes Operating key Indication after operationCondition Code Status Power can not be Turned on No Operation at All Troubleshooting FlowchartsPreliminary checks Checking Procedure Power can not be Turned on after Replacing Indoor PC BoardOutdoor Unit does not Operate Only Compressor does not Operate Only Outdoor Fan does not Operate Check procedure Only the Indoor Fan does not OperateThere is no beep from Inspection procedures How to Check the PC BoardOperating precautions Main PC board partProcedure Check Point Symptom Causes PC Board Layout Top View Bottom ViewHow to Reduce the Operation Time of the Anti-Restart Timer SensorPart Replacement Indoor Unit RAS-10SK-E, RAS-10SKXPart name Procedure Remarks Microcomputer RAS-10SK-E, RAS-10SKX Outdoor Unit RAS-10SA-E, RAS-10SAX OFF Exploded Views and Parts List Part DescriptionIndoor Unit Capillary Tube