Toshiba RAS 10 Air Conditioner Series Official Manual and Construction Views

Page 6

 

 

 

 

 

 

2.

 

CONSTRUCTION VIEWS

 

2-1. Indoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAS-10SK-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAS-10SKX

Air inlet

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

 

Heat exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

790

 

 

 

 

 

 

 

 

 

174

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

265

ÄÄÄÄÄÄ¿@¿@@¿¿@@¿¿

 

 

,,,,,,@

1800

10SK-E : Without power cord

47

Air outlet

 

10SKX : With power cord

 

10 50

Knock out system

790

232

 

326

 

232

Hanger

Front panel

Back body

47 50

Drain hose (0.54m)

 

321

10

 

Hanger

 

 

 

Knock out system

 

 

 

 

Connecting pipe (0.39m)

Connecting pipe (0.49m)

 

(Flare ø9.52)

(Flare ø6.35)

 

 

65.5

 

659

65.5

Hanger

Wireless

 

 

 

 

450

 

 

 

 

 

 

For stud bolt

remote

 

Hanger

 

326

 

control

 

 

 

(ø8~ø10)

 

 

 

 

66 or more

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

 

For stud bolt

 

46

20

2.5

 

distance

20

(ø6)

 

 

to ceiling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

 

Minimum

 

 

20

Minimum

Remote

265

17

distance

 

 

distance to wall

control

to wall

 

 

 

holder

 

 

120 or more

 

 

120 or more

 

40.5

3.5

 

 

 

37

40.5

 

 

Hanger

Hanger

 

 

 

 

 

 

 

 

 

 

 

Center line

Installation

 

 

59.6

 

 

 

plate outline

 

 

 

 

 

 

60.5

 

 

 

 

 

 

 

 

 

 

 

 

 

76

319

269

126

 

 

 

 

 

 

790

 

 

 

 

 

 

 

– 6 –

 

 

136

16

112.8 5

Image 6
Contents R C O Contents Troubleshooting Flowcharts What to be Prechecked FirstPrimary Judgement of Trouble Sources Specifications RAS-10SK-E/10SA-E RAS-10SKX/10SAX CoolingCondition JIS C9612-1994 Temperature Cooling Construction Views Indoor UnitOutdoor Unit RAS-10SA-E RAS-10SAXWiring Diagram Main P.C. BoardSpecifications of Electrical Parts Parts name Type SpecificationsRefrigerant Cycle Diagram RAS-10SK-E / RAS-10SA-E RAS-10SKX / RAS-10SAXMICRO-COMPUTER Block Diagram AUTO, COOL, DRY, FAN onlyCool Operation Operation DescriptionsFAN only Operation M3/hDRY Operation Louver ControlAuto Operation Temporary AutoECONO. Mode Low-Temperature Limit Control Cooling OperationCooling How to Set the Auto Restart Auto Restart FunctionHow to Cancel the Auto Restart Case of Power Failure during the Timer OperationInstallation Procedure Safety Cautions For general public useUK Plugs and Sockets etc Safety Regulations SI Number Installation Diagram of Indoor and Outdoor Units AttachInstallation Installation PartsOptional Parts Remote control Installation placeCutting a Hole and Mounting Installation Plate Mounting the installation plateWhen the installation plate is directly mounted on the wall Electrical WorkHow to open the screw cap Wiring ConnectionHow to remove the front cabinet Taking out the power cordStripping length of connecting cable How to install the front cabinet on the indoor unitCase of downward piping Piping and Drain Hose InstallationCase of rightward piping Left-hand connection with pipingIndoor Unit Installation DrainageStrong wind Flaring Refrigerant Piping ConnectionVacuum Pumping Tightening connectionPacked Valve Handling Precautions A5 mm hexagon wrench is requiredOthers Auto Restart SettingHow to set the Auto Restart Gas Leak TestWhat to be Prechecked First Troubleshooting ChartPower Supply Voltage Incorrect Cable Connection between Indoor and Outdoor UnitsMisleading but Good Operations Program Controlled Operation Operation of air-conditioner DescriptionPrimary Judgement of Trouble Sources Role of Indoor Unit ControllerBlock display Self-diagnosis with remote control Selecting ordinary modeSelf-diagnosis by check codes Operating key Indication after operationCondition Code Status Troubleshooting Flowcharts Power can not be Turned on No Operation at AllPreliminary checks Power can not be Turned on after Replacing Indoor PC Board Checking ProcedureOutdoor Unit does not Operate Only Compressor does not Operate Only Outdoor Fan does not Operate Check procedure Only the Indoor Fan does not OperateThere is no beep from Inspection procedures How to Check the PC BoardOperating precautions Main PC board partProcedure Check Point Symptom Causes PC Board Layout Top View Bottom ViewHow to Reduce the Operation Time of the Anti-Restart Timer SensorPart Replacement Indoor Unit RAS-10SK-E, RAS-10SKXPart name Procedure Remarks Microcomputer RAS-10SK-E, RAS-10SKX Outdoor Unit RAS-10SA-E, RAS-10SAX OFF Exploded Views and Parts List Part DescriptionIndoor Unit Capillary Tube