8. INSTALLATION PROCEDURE

8-1. Safety Cautions

For general public use

Power supply cord of parts of appliance for Outdoor use shall be more than polychloroprene sheathed flexible cord (design H05 RN-F), or cord designation 245 IEC 57.

CAUTION

TO DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY.

This appliance must be connected to the mains by means of a circuit breaker or a switch with a contact separation of at least 3 mm.

If this is not possible, a power supply plug with earth must be used. This plug must be easily accessible after installation. The plug must be disconnected from the power supply socket in order to disconnect the appliance completely from the mains.

DANGER

`FOR USE BY QUALIFIED PERSONS ONLY.

`TURN OFF MAIN POWER SUPPLY AND BREAKER BEFORE ATTEMPTING ANY ELECTRICAL WORK.

MAKE SURE ALL POWER SWITCHES AND BREAKER TURN OFF. FAILURE TO DO SO MAY CAUSE ELECTRICAL SHOCK.

`CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED BY WRONG WAY, ELECTRIC PARTS MAY BE DAMAGED.

`CHECK THE EARTH WIRE IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.

`DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OF GAS VAPORS. FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.

`TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2M.) FROM HEAT SOURCES SUCH AS RADIATORS, HEAT RESISTORS, FURNACE, STOVES, ETC..

`WHEN MOVING THE AIR-CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED REFRIGERANT (R-22) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS.

`IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS.

WARNING

Never modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches.

Do not install in a place which cannot bear the weight of the unit.

Personal injury and property damage can result if the unit falls.

Before doing the electrical work, attach an approved plug to the power supply cord. And make sure the equipment to be earthed.

Appliance shall be installed in accordance with national wiring requlations.

If you detect any damage, do not install the unit. Contact your Toshiba dealer immediately.

– 18 –

Image 18
Contents R C O Contents Troubleshooting Flowcharts What to be Prechecked FirstPrimary Judgement of Trouble Sources Specifications RAS-10SK-E/10SA-E RAS-10SKX/10SAX CoolingCondition JIS C9612-1994 Temperature Cooling Construction Views Indoor UnitOutdoor Unit RAS-10SA-E RAS-10SAXWiring Diagram Main P.C. BoardSpecifications of Electrical Parts Parts name Type SpecificationsRefrigerant Cycle Diagram RAS-10SK-E / RAS-10SA-E RAS-10SKX / RAS-10SAXMICRO-COMPUTER Block Diagram AUTO, COOL, DRY, FAN onlyCool Operation Operation DescriptionsFAN only Operation M3/hDRY Operation Louver ControlAuto Operation Temporary AutoECONO. Mode Low-Temperature Limit Control Cooling OperationCooling How to Set the Auto Restart Auto Restart FunctionHow to Cancel the Auto Restart Case of Power Failure during the Timer OperationInstallation Procedure Safety Cautions For general public useUK Plugs and Sockets etc Safety Regulations SI Number Installation Diagram of Indoor and Outdoor Units AttachInstallation Installation PartsOptional Parts Remote control Installation placeCutting a Hole and Mounting Installation Plate Mounting the installation plateWhen the installation plate is directly mounted on the wall Electrical WorkHow to open the screw cap Wiring ConnectionHow to remove the front cabinet Taking out the power cordStripping length of connecting cable How to install the front cabinet on the indoor unitCase of downward piping Piping and Drain Hose InstallationCase of rightward piping Left-hand connection with pipingIndoor Unit Installation DrainageStrong wind Flaring Refrigerant Piping ConnectionVacuum Pumping Tightening connectionPacked Valve Handling Precautions A5 mm hexagon wrench is requiredOthers Auto Restart SettingHow to set the Auto Restart Gas Leak TestWhat to be Prechecked First Troubleshooting ChartPower Supply Voltage Incorrect Cable Connection between Indoor and Outdoor UnitsMisleading but Good Operations Program Controlled Operation Operation of air-conditioner DescriptionPrimary Judgement of Trouble Sources Role of Indoor Unit ControllerBlock display Self-diagnosis with remote control Selecting ordinary modeSelf-diagnosis by check codes Operating key Indication after operationCondition Code Status Troubleshooting Flowcharts Power can not be Turned on No Operation at AllPreliminary checks Power can not be Turned on after Replacing Indoor PC Board Checking ProcedureOutdoor Unit does not Operate Only Compressor does not Operate Only Outdoor Fan does not Operate Check procedure Only the Indoor Fan does not OperateThere is no beep from Inspection procedures How to Check the PC BoardOperating precautions Main PC board partProcedure Check Point Symptom Causes PC Board Layout Top View Bottom ViewHow to Reduce the Operation Time of the Anti-Restart Timer SensorPart Replacement Indoor Unit RAS-10SK-E, RAS-10SKXPart name Procedure Remarks Microcomputer RAS-10SK-E, RAS-10SKX Outdoor Unit RAS-10SA-E, RAS-10SAX OFF Exploded Views and Parts List Part DescriptionIndoor Unit Capillary Tube