Toshiba RAS-10SAX, RAS-10SA-E Specifications, RAS-10SK-E/10SA-E RAS-10SKX/10SAX Cooling

Page 4

 

 

1.

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

 

Model

 

RAS-10SK-E/10SA-E

 

RAS-10SKX/10SAX

 

 

 

 

 

 

 

 

 

 

COOLING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

 

*1 kW

 

220V

 

230V

 

240V

 

220V

 

230V

 

240V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.65

 

2.65

 

2.70

 

2.70

 

2.70

 

2.70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phase

 

 

 

 

 

Single

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power source

 

 

 

 

V

 

 

 

 

220/230/240

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hz

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption

 

 

 

 

kW

 

 

 

 

0.83/0.85/0.88

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

 

%

 

 

 

 

95/92/90

 

 

 

 

Running current

 

 

 

 

A

 

 

220V

 

 

230V

 

 

240V

 

 

 

 

Indoor/Outdoor

 

0.15/3.82

 

0.15/3.87

 

0.15/3.92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Starting current

 

 

 

 

A

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture removal

 

 

 

 

lit/h

 

 

 

 

 

 

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noise

Indoor (H/M/L)

 

 

 

dB

 

 

 

 

44/36/31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor (220/230/240V)

 

dB

 

 

 

 

44/45/45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant

Name of refrigerant

 

 

 

 

 

 

 

 

R-22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated volume

 

 

 

kg

 

 

 

 

 

 

0.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

 

 

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas side size

 

 

 

mm

 

 

 

 

 

 

9.52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection type

 

 

 

 

 

 

 

 

 

Flare connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid side size

 

 

 

mm

 

 

 

 

 

 

6.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interconnection pipe

Connection type

 

 

 

 

 

 

 

 

 

Flare connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum length (of one way) m

*2

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum height difference

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

m

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensate drain pipe

Outer diameter

 

 

 

mm

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR UNIT

 

 

 

 

 

 

 

 

 

RAS-10SK-E/RAS-10SKX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

 

 

mm

 

 

 

 

 

 

265

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

Width

 

 

 

mm

 

 

 

 

 

 

790

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

 

 

 

mm

 

 

 

 

 

 

174

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

 

 

 

kg

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator type

 

 

 

 

 

 

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor fan type

 

 

 

 

 

 

 

 

 

 

Cross flow fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High fan

 

 

 

m3/h

 

 

 

 

 

 

650

 

 

 

 

Air volume

Medium fan

 

 

 

m3/h

 

 

 

 

 

 

510

 

 

 

 

 

Low fan

 

 

 

m3/h

 

 

 

 

 

 

430

 

 

 

 

Fan motor output

 

 

 

 

W

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

 

 

Polypropylene net filter (Washable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR UNIT

 

 

 

 

 

 

 

 

 

RAS-10SA-E/RAS-10SAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

 

 

mm

 

 

 

 

 

 

530

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

Width

 

 

 

mm

 

 

 

 

 

 

770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

 

 

 

mm

 

 

 

 

 

 

200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

 

 

 

kg

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condenser type

 

 

 

 

 

 

 

 

 

 

Finned tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor fan type

 

 

 

 

 

 

 

 

 

 

Propeller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow volume

 

 

 

 

m3/h

 

 

 

 

 

 

1600

 

 

 

 

Fan motor output

 

 

 

 

W

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

Model

 

 

 

 

 

 

 

 

 

PH102T1-4C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

W

 

 

 

 

 

 

750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety device

 

 

 

 

 

 

 

 

 

 

Fuse, Overload relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto louver

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Usable outdoor temperature range

 

 

 

°C

 

 

 

 

21 ~ 43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications are subject to change without notice.

– 4 –

Image 4
Contents R C O Contents What to be Prechecked First Troubleshooting FlowchartsPrimary Judgement of Trouble Sources Specifications RAS-10SK-E/10SA-E RAS-10SKX/10SAX CoolingCondition JIS C9612-1994 Temperature Cooling Construction Views Indoor UnitOutdoor Unit RAS-10SA-E RAS-10SAXWiring Diagram Main P.C. BoardSpecifications of Electrical Parts Parts name Type SpecificationsRefrigerant Cycle Diagram RAS-10SK-E / RAS-10SA-E RAS-10SKX / RAS-10SAXMICRO-COMPUTER Block Diagram AUTO, COOL, DRY, FAN onlyOperation Descriptions FAN only OperationCool Operation M3/hDRY Operation Louver ControlAuto Operation Temporary AutoLow-Temperature Limit Control Cooling Operation ECONO. ModeCooling How to Set the Auto Restart Auto Restart FunctionHow to Cancel the Auto Restart Case of Power Failure during the Timer OperationInstallation Procedure Safety Cautions For general public useUK Plugs and Sockets etc Safety Regulations SI Number Installation Diagram of Indoor and Outdoor Units AttachInstallation Parts InstallationOptional Parts Installation place Cutting a Hole and Mounting Installation PlateRemote control Mounting the installation plateWhen the installation plate is directly mounted on the wall Electrical WorkWiring Connection How to remove the front cabinetHow to open the screw cap Taking out the power cordStripping length of connecting cable How to install the front cabinet on the indoor unitPiping and Drain Hose Installation Case of rightward pipingCase of downward piping Left-hand connection with pipingIndoor Unit Installation DrainageStrong wind Refrigerant Piping Connection Vacuum PumpingFlaring Tightening connectionPacked Valve Handling Precautions A5 mm hexagon wrench is requiredAuto Restart Setting How to set the Auto RestartOthers Gas Leak TestTroubleshooting Chart Power Supply VoltageWhat to be Prechecked First Incorrect Cable Connection between Indoor and Outdoor UnitsMisleading but Good Operations Program Controlled Operation Operation of air-conditioner DescriptionRole of Indoor Unit Controller Primary Judgement of Trouble SourcesBlock display Self-diagnosis with remote control Selecting ordinary modeSelf-diagnosis by check codes Operating key Indication after operationCondition Code Status Power can not be Turned on No Operation at All Troubleshooting FlowchartsPreliminary checks Checking Procedure Power can not be Turned on after Replacing Indoor PC BoardOutdoor Unit does not Operate Only Compressor does not Operate Only Outdoor Fan does not Operate Check procedure Only the Indoor Fan does not OperateThere is no beep from How to Check the PC Board Operating precautionsInspection procedures Main PC board partProcedure Check Point Symptom Causes PC Board Layout Top View Bottom ViewHow to Reduce the Operation Time of the Anti-Restart Timer SensorPart Replacement Indoor Unit RAS-10SK-E, RAS-10SKXPart name Procedure Remarks Microcomputer RAS-10SK-E, RAS-10SKX Outdoor Unit RAS-10SA-E, RAS-10SAX OFF Exploded Views and Parts List Part DescriptionIndoor Unit Capillary Tube