5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-10YKV-E, RAS-13YKV-E
No. | Parts name | Type | Specifications | |
|
|
|
| |
1 | Fan motor (for indoor) | DC35V, 19W | ||
|
|
|
| |
2 | Thermo. sensor | ( – ) | 10kΩ at 25°C | |
|
|
|
| |
3 | DC390V, Secondary DC35V, 12V, 7V | |||
|
|
|
| |
4 | Microcomputer | TMP87PM40AF or TMP87CM40AF |
| |
|
|
|
| |
5 | Heat exchanger temp. sensor | ( – ) | 10kΩ at 25°C | |
|
|
| ||
|
|
|
| |
6 | Line filter (L01) | 25mH, AC0,7A | ||
|
|
|
| |
7 | Diode (DB01) | 4A, 600V | ||
|
|
|
| |
8 | Capacitor (C02) | KMH450VNSN100M25B | 100µF, 450V | |
|
|
|
| |
9 | Fuse (F01) | TSCR6,3A | T6,3A, 250V | |
|
|
|
| |
10 | Power supply IC (IC01) | 4A, 600V | ||
|
|
|
| |
11 | Varistor (R21, R109) | 15G561K | 560V | |
|
|
|
| |
12 | Resistor (R01) | 5,6Ω , 5W | ||
|
|
|
| |
13 | Louver motor | MP35EA7 | Output (Rated) 2W, 10poles, 1phase DC12V | |
|
|
|
|
5-2. Outdoor Unit
RAS-10YAV-E, RAS-13YAV-E
No. | Parts name | Model name |
| Rating | ||
|
|
|
|
| ||
1 | SC coil | L03 | 15A, 0,6mH | |||
(Noise filter) | L01 | 20A, 150µH | ||||
| ||||||
|
|
|
|
| ||
2 | Primary side DC280V, Secondary side | |||||
7,5V x 1, 13V x 1, 26,5V x 3, 16V x 1, 15V x 1 | ||||||
|
|
|
| |||
|
|
|
|
| ||
3 | Reactor |
| L=10mH, 16A x 2 | |||
|
|
|
| |||
4 | Outside fan motor | DC140V, 40W | ||||
|
|
|
|
| ||
5 | Fan control relay | AJQ1341 | Coil DC12V | |||
Contact AC125V, 3A | ||||||
|
|
|
| |||
|
|
|
|
| ||
6 | Suction temp. sensor | (Inverter attached) | 10kΩ | (25°C) | ||
(TS sensor) |
| |||||
|
|
|
|
| ||
|
|
|
|
| ||
7 | Discharge temp. sensor | (Inverter attached) | 62kΩ | (20°C) | ||
(TD sensor) |
| |||||
|
|
|
|
| ||
|
|
|
|
| ||
8 | Outside air temp. sensor | (Inverter attached) | 10kΩ | (25°C) | ||
(TO sensor) |
| |||||
|
|
|
|
| ||
|
|
|
|
| ||
9 | Heat exchanger temp. | (Inverter attached) | 10kΩ | (25°C) | ||
sensor (TE sensor) | ||||||
|
|
|
| |||
|
|
|
| |||
10 | Terminal block (9P) | 20A, AC250V | ||||
|
|
|
|
| ||
|
|
| For protection of switching power source | 3,15A, AC250V | ||
|
|
|
|
| ||
11 | Fuse |
| For protection of transistor module breakage | 15A, AC250V | ||
|
|
|
|
| ||
|
|
| For protection of inverter input overcurrent | 25A, AC250V | ||
|
|
|
| |||
12 | Electrolytic capacitor | LLQ2G501KHUATF, 400LISN500K35F | 500µF, DC400V X 3 pieces | |||
|
|
|
| |||
13 | Transistor module | 25A, 600V | ||||
|
|
|
|
| ||
14 | Compressor |
| ||||
|
|
|
| |||
15 | Compressor thermo. | OFF: 125 ± 4°C, ON: 90 ± 5° C | ||||
|
|
|
| |||
16 | Converter module | MP7003 | Diode: 25A, 600V, IGBT: 40A, 600V | |||
|
|
|
|
|
|
– 18 –