Toshiba RAS-10YKV-E, RAS-13YKV-E How to examine whether remote controller is good or bad

Page 49

(5) How to examine whether remote controller is good or bad

 

 

Operation

 

 

 

Check Items

 

 

There is no beep from

 

 

 

Considerable main cause

Push the START/STOP button.

the indoor unit.

 

 

The operation lamp of

 

 

 

 

 

 

the air conditioner main

Measures

Does the transmission

NO

unit does not light.

 

 

Item by symptom

indicator of remote

 

 

controller light?

 

 

 

 

 

 

YES

 

 

Is there direct

NO

 

 

 

 

Take out the batteries and

sunlight on the

 

 

 

 

insert them again.

receptor of the

 

 

 

 

 

 

(rear side of remote controller)

air conditioner?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

Is operation

 

 

 

 

 

 

 

 

 

 

 

Is there any

NO

NO

possible when the

 

thyristor

transmitter is moved

 

fluorescent light

 

 

nearer to the infrared

 

near by?

 

 

signal receiver of the

 

 

YES

 

 

air conditioner?

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery life

 

 

 

 

 

 

 

 

Avoid direct sunlight.

 

 

 

 

 

Is Temporary Cool

 

 

 

 

 

NO

operation possible when

 

 

 

 

 

keeping the temporary

 

 

 

 

 

 

 

 

switch of the air conditioner

 

 

 

 

 

 

 

 

main unit pressed for

 

 

 

 

 

 

 

 

10 seconds or more?

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Can any signal tone

 

 

 

 

 

 

 

 

be heard in a transistor

NO

 

 

 

 

 

 

 

radio when transmitting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

within 5cm distance

 

 

 

 

 

 

 

 

from the radio?

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keep the air

 

 

 

 

 

 

 

 

 

conditioner away

 

Replace

 

 

 

 

 

 

 

 

 

Replace the

 

 

 

from thyristor

 

 

 

 

 

 

 

P.C. board.

 

 

 

 

 

fluorescent light.

 

 

 

battery.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Push the START/

STOP button

Does the transmission

NO

indicator light?

 

 

YES

 

 

 

 

 

 

Is there any receiving sound and operation?

YES

 

Remote

Normal

controller

 

is failure.

– 49 –

Image 49
Contents AIR-CONDITIONER Contents Specifications SpecificationsRAS-10YKV-E/RAS-10YAV-E RAS-13YKV-E RAS-13YKV-E/RAS-13YAV-ECapacity Variation Ratio According to Temperature Operation Characteristic CurveCooling Heating CoolingRefrigerant Piping Installation Safety During Installation/ServicingRefrigerant R410A Piping Materials and Joints Used1 Thicknesses of annealed copper pipes Thickness mm Processing of Piping MaterialsOuter diameter mm R410A R22 Nominal diameter4 Dimensions related to flare processing for R22 Outer 3 Dimensions related to flare processing for R410A Outer5 Flare and flare nut dimensions for R410A Outer Thickness Dimension mmWrenches available on the market Nm kgfcmTools R410A air conditioner Conventional air InstallationRequired Tools General tools Conventional tools can be usedRecharging of Refrigerant 1 Configuration of refrigerant chargingMaterials for Brazing Brazing of PipesFlux Never use gas other than Nitrogen gas BrazingIndoor Unit Construction ViewsRAS-10YKV-E, RAS-13YKV-E RAS-10YAV-E RAS-13YAV-E Outdoor Unit1 Simple check points for diagnosing faults Wiring DiagramCheck items Diagnosis result V. Pulse Modulating Valve RAS-10YAV-E, RAS-13YAV-EParts name Type Specifications Specifications of Electrical PartsParts name Model name Rating Refrigerant Cycle Diagram Refrigerant Cycle DiagramRAS-10YKV-E/RAS-10YAV-E RAS-13YKV-E/RAS-13YAV-E Cooling Operation DataHeating Remote Controller Control Block DiagramRAS AssemblyMCC808 P.C.B Outline of Air Conditioner Control Operation DescriptionCapacity Control Power Factor Improvement ControlCurrent Release Control 1 Compressor revolution range5. P. M. V. Pulse Modulating Valve Prevent-Freezing ControlLouver Control Indoor Fan Control DC Fan MotorOutdoor Fan Control DC Fan Motor Description of Operation CircuitCOOL, DRY HeatPrevent-freezing control Outdoor temperature release controlCurrent release control Louver control RpsECONO. operation control 5 Setting of air flowBasic control Heating OperationStarting and in stability Cold draft preventing controlDefrost control Automatic Operation Temporary OperationTemporary Auto Operation Temporary Cooling OperationAuto Restart Function How to Set the Auto RestartOperation Motion Case of Power Failure during the Timer Operation How to Cancel the Auto RestartParts Name of Remote Controller Remote ControllerName of Indications on Remote Controller START/STOP buttonSafety Cautions Installation ProcedureRemark per EMC Directive 89/336/EEC Indoor Unit Optional Installation PartsElectrical Work Refrigerant Piping Connection Outdoor UnitConfirmation of Power Supply HOW to Diagnose the TroubleConfirmation of Power Voltage First ConfirmationOperation Which is not a Trouble Program Operation Primary JudgmentOperation of air conditioner Description Check Block display Description for self-diagnosis Code Judgment by Flashing LED of Indoor UnitOperation Control by Rated Frequency in Service Mode Self-Diagnosis by Remote Controller Check CodeSelf-Diagnosis ButtonBlock distinction Check outdoor heat exchanger temp Indoor Unit Including Remote Controller Judgment of Trouble by Every SymptomConfirmation procedure Power is not turned on Does not operate entirelyYES Only the indoor fan does not operateCause How to examine whether remote controller is good or bad Check procedure Select phenomena described below Wiring Failure Interconnecting and Serial Signal WireOutdoor unit does not operate Check procedure Check Code 1C Miswiring in indoor/outdoor units and 1ESummarized Inner Diagnosis of Inverter Assembly How to Diagnose Trouble in Outdoor UnitDiagnosis/Process flowchart Contents Summary How to Check the P.C. Board Indoor Unit How to Check Simply the Main PartsOperating precautions Inspection proceduresProcedure Check point Symptom Causes Check procedures10-8-2. P.C. Board Layout Sensor characteristic tableBottom View Indoor Unit Other Parts Part name Checking procedureOutdoor Unit Position Resistance valueCase that product is good Checking Method for Each PartSymptom How to Simply Judge Whether Outdoor Fan Motor is Good or BadPart name Procedure Remarks HOW to Replace the Main Parts11-1 Indoor Unit To assemble the front panelRemoving Louver motor Board layout MicrocomputerDetachment No. Part name Procedure RemarksAttachment High-voltage circuit is incorporated in it Be careful to check the inverter becauseBundled PartLead wires Propeller Flange nut is loosened by turning clockwise Side and B room side. After mounting it Pulse modulating valve has a roomCheck that coil at B room side Red Perform work on a corrugated cardboardParts name Qty Remarks Part name Procedure RemarksMCC-808 Part Description Exploded Views and Parts ListLocation Part Description 222 43T49023 Holder of Plate of EVA-SEAL 11, 13 12 24, 25 26, 27 12-3. P.C. Board Layout Toshiba Carrier Corporation Turn 208 10YKV-E 221 Cushion, Rubber Valve, 4-way To Sensor Ø6