HP Cooktop 10GBE manual Regulatory compliance notices

Page 29

WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:

Do not try to open the module enclosure. There are no user-serviceable components inside.

Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.

Allow only HP Authorized Service technicians to repair the unit.

The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.

Regulatory compliance notices 29

Image 29
Contents Part Number December 2010 Second Edition 10GbE Pass-Thru Module User GuideIntended audience Contents Electrostatic discharge Pass-thru module architecture FeaturesIntroduction Redundant paths to server bays XModemPort mapping Dual pass-thru modules Component identification Resets10GbE Pass-Thru Module front panel DescriptionDescription Manually configuring the pass-thru module Installing the pass-thru moduleInstalling the module Module securityAccessing the pass-thru module CLI remotely Accessing the pass-thru module CLIProduction mode CLI Accessing the pass-thru module CLI locallyCommand Result CLI menuInstalling SFP+ transceivers Replacing an existing module Replacing a pass-thru moduleMethods for updating the 10GbE Pass-Thru Module firmware Updating the 10GbE pass-thru firmwareEnter R. The following message appears Enter C. The following message appearsEnter N. The following message appears Enter y. The following message appearsEnter x. The following message appears Configuration Script Files Usb//d1/test.cfg Performing a serial firmware image download Updating the firmware image using the serial portBaud rate 9600 Data bits Parity None Stop bits Flow control Additional references For more informationCause Action TroubleshootingHealth LED on the pass-thru module is not on Try another mini-USB to DB-9 RS232 cable Download fails after starting to download the firmware file Pass-thru module configuration is corruptSFP+ transceiver port is disabled General specifications Technical specificationsCategory Specification Port namesMini-USB to DB-9 serial adapter pin assignment Physical and environmental specificationsFrom Wire Shell Braid Technical specifications Regulatory compliance notices Regulatory compliance notices Regulatory compliance notices Grounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Acronyms and abbreviations Network access server Media Access ControlPower-On Self Test Local-area networkIndex Index