NOTE: If you are using a USB key to transfer the firmware file, see "Updating the firmware image using a USB key and the Onboard Administrator CLI (on page 17)" for steps that must be completed before beginning this procedure.
1.Access the Onboard Administrator CLI remotely using Telnet or SSH, or locally using a serial connection to the active Onboard Administrator DB9 serial connector, or VGA and keyboard connected to the enclosure KVM ports. For more information on how to access the Onboard Administrator CLI, see the HP BladeSystem Onboard Administrator User Guide.
2.Log in to the active Onboard Administrator with a valid username and password that has a role on the Onboard Administrator allowing access to the
NOTE: The
3.At the Onboard Administrator prompt, enter connect interconnect 2. The following message appears:
NOTICE: This
Connecting to integrated switch 2 at 9600,N81...
Escape character is '<Ctrl>_' (Control + Shift + Underscore)
4.To display the
5.Press Ctrl + Shift + _. The following message appears:
Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send >
6.Enter C. The following message appears:
Change settings for: L)ocal Session, R)emote Port [I/O Bay 2], E)xit
7.Enter R. The following message appears:
Settings: B)audrate; flow control: N)one H)ardware S)oftware; E)xit >
8.Enter N. The following message appears:
Connected to integrated switch 2 at 9600,N81.
Escape character is '<Ctrl>_' (Control + Shift + Underscore)
9.At the 10GbE
[System Menu]
info | - | System Information Display |
config | - | Set Active or Factory Default Config |
dumpconfig - Dump Saved Config | ||
xmodem | - Download new image using XMODEM | |
reset | - | Reset The Switch |
10.At the System# prompt, enter xmodem. The following message appears:
Confirm reset and start XMODEM download mode [y/n]:
11.Enter y. The following message appears:
System Reset ...
Ready to begin XMODEM file transfer. Hit return to continue.
Updating the 10GbE