HP Cooktop 10GBE Enter C. The following message appears, Enter R. The following message appears

Page 15

NOTE: If you are using a USB key to transfer the firmware file, see "Updating the firmware image using a USB key and the Onboard Administrator CLI (on page 17)" for steps that must be completed before beginning this procedure.

1.Access the Onboard Administrator CLI remotely using Telnet or SSH, or locally using a serial connection to the active Onboard Administrator DB9 serial connector, or VGA and keyboard connected to the enclosure KVM ports. For more information on how to access the Onboard Administrator CLI, see the HP BladeSystem Onboard Administrator User Guide.

2.Log in to the active Onboard Administrator with a valid username and password that has a role on the Onboard Administrator allowing access to the pass-thru interconnect module.

NOTE: The pass-thru module in the examples below is located in interconnect bay 2. Wherever the 2 appears, substitute the number of the interconnect bay your pass-thru module is installed into.

3.At the Onboard Administrator prompt, enter connect interconnect 2. The following message appears:

NOTICE: This pass-thru connection to the integrated I/O console is provided for convenience and does not supply additional access control. For security reasons, use the password features of the integrated switch.

Connecting to integrated switch 2 at 9600,N81...

Escape character is '<Ctrl>_' (Control + Shift + Underscore)

4.To display the pass-thru module console, press Enter.

5.Press Ctrl + Shift + _. The following message appears:

Command: D)isconnect, C)hange settings, send B)reak, E)xit command mode X)modem send >

6.Enter C. The following message appears:

Change settings for: L)ocal Session, R)emote Port [I/O Bay 2], E)xit

7.Enter R. The following message appears:

Settings: B)audrate; flow control: N)one H)ardware S)oftware; E)xit >

8.Enter N. The following message appears:

Connected to integrated switch 2 at 9600,N81.

Escape character is '<Ctrl>_' (Control + Shift + Underscore)

9.At the 10GbE Pass-Thru # prompt, enter /system. The following message appears:

[System Menu]

info

-

System Information Display

config

-

Set Active or Factory Default Config

dumpconfig - Dump Saved Config

xmodem

- Download new image using XMODEM

reset

-

Reset The Switch

10.At the System# prompt, enter xmodem. The following message appears:

Confirm reset and start XMODEM download mode [y/n]:

11.Enter y. The following message appears:

System Reset ...

Ready to begin XMODEM file transfer. Hit return to continue.

Updating the 10GbE pass-thru firmware 15

Image 15
Contents Part Number December 2010 Second Edition 10GbE Pass-Thru Module User GuideIntended audience Contents Electrostatic discharge Features IntroductionPass-thru module architecture XModem Port mapping Dual pass-thru modulesRedundant paths to server bays Description ResetsComponent identification 10GbE Pass-Thru Module front panelDescription Module security Installing the pass-thru moduleManually configuring the pass-thru module Installing the moduleAccessing the pass-thru module CLI remotely Accessing the pass-thru module CLICLI menu Accessing the pass-thru module CLI locallyProduction mode CLI Command ResultInstalling SFP+ transceivers Replacing an existing module Replacing a pass-thru moduleMethods for updating the 10GbE Pass-Thru Module firmware Updating the 10GbE pass-thru firmwareEnter y. The following message appears Enter C. The following message appearsEnter R. The following message appears Enter N. The following message appearsEnter x. The following message appears Configuration Script Files Usb//d1/test.cfg Performing a serial firmware image download Updating the firmware image using the serial portBaud rate 9600 Data bits Parity None Stop bits Flow control Additional references For more informationTroubleshooting Health LED on the pass-thru module is not onCause Action Try another mini-USB to DB-9 RS232 cable Pass-thru module configuration is corrupt SFP+ transceiver port is disabledDownload fails after starting to download the firmware file Port names Technical specificationsGeneral specifications Category SpecificationPhysical and environmental specifications From WireMini-USB to DB-9 serial adapter pin assignment Shell Braid Technical specifications Regulatory compliance notices Regulatory compliance notices Regulatory compliance notices Electrostatic discharge Preventing electrostatic dischargeGrounding methods to prevent electrostatic discharge Acronyms and abbreviations Local-area network Media Access ControlNetwork access server Power-On Self TestIndex Index