HP Cooktop 10GBE manual Updating the 10GbE pass-thru firmware

Page 14

Updating the 10GbE pass-thru firmware

Methods for updating the 10GbE Pass-Thru Module firmware

CAUTION: The pass-thru module automatically reboots after the firmware update, which disrupts all server traffic on all ports on this pass-thru module. The server blades can be powered on while this pass-thru module firmware is updated, but they lose connectivity while the firmware reboots on each pass-thru module.

CAUTION: Do not power off the pass-thru module during the download process. Doing so will require you to power cycle the pass-thru module. Power cycling requires a successful image download before the pass-thru module is operable.

The 10GbE Pass-Thru Module firmware can be updated using the following methods:

Onboard Administrator CLI

o Remotely through the management network

o Locally using a PC connected to the Onboard Administrator DB9 serial port

o Locally through a VGA and keyboard connected to the Onboard Administrator Enclosure KVM CLI console, if you are using an HP BladeSystem c7000 Onboard Administrator with KVM or the c3000 KVM option

NOTE: When using the Onboard Administrator for the firmware update, the pass-thru module firmware image must be available on an HTTP, FTP, or TFTP file, or located on a USB key drive accessible by the active Onboard Administrator.

Locally using a PC connected to the pass-thru serial connector

NOTE: If you are using a local PC to update the firmware, the pass-thru module firmware image must be accessible from that PC.

NOTE: The pass-thru module boot code firmware image is usually named 10GPTHRU- w.x.y.z_FW.bin, where w.x.y.z is the firmware version number.

Updating the firmware image using the Onboard Administrator CLI

NOTE: The firmware update uses the Onboard Administrator Xmodem support with a firmware file hosted on an HTTP, FTP, or TFTP server. The firmware transfer can take up to seven minutes to complete.

Updating the 10GbE pass-thru firmware 14

Image 14
Contents 10GbE Pass-Thru Module User Guide Part Number December 2010 Second EditionIntended audience Contents Electrostatic discharge Pass-thru module architecture FeaturesIntroduction Redundant paths to server bays XModemPort mapping Dual pass-thru modules 10GbE Pass-Thru Module front panel ResetsComponent identification DescriptionDescription Installing the module Installing the pass-thru moduleManually configuring the pass-thru module Module securityAccessing the pass-thru module CLI Accessing the pass-thru module CLI remotelyCommand Result Accessing the pass-thru module CLI locallyProduction mode CLI CLI menuInstalling SFP+ transceivers Replacing a pass-thru module Replacing an existing moduleUpdating the 10GbE pass-thru firmware Methods for updating the 10GbE Pass-Thru Module firmwareEnter N. The following message appears Enter C. The following message appearsEnter R. The following message appears Enter y. The following message appearsEnter x. The following message appears Configuration Script Files Usb//d1/test.cfg Updating the firmware image using the serial port Performing a serial firmware image downloadBaud rate 9600 Data bits Parity None Stop bits Flow control For more information Additional referencesCause Action TroubleshootingHealth LED on the pass-thru module is not on Try another mini-USB to DB-9 RS232 cable Download fails after starting to download the firmware file Pass-thru module configuration is corruptSFP+ transceiver port is disabled Category Specification Technical specificationsGeneral specifications Port namesMini-USB to DB-9 serial adapter pin assignment Physical and environmental specificationsFrom Wire Shell Braid Technical specifications Regulatory compliance notices Regulatory compliance notices Regulatory compliance notices Grounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Acronyms and abbreviations Power-On Self Test Media Access ControlNetwork access server Local-area networkIndex Index