HP Cooktop 10GBE manual Accessing the pass-thru module CLI locally, Production mode CLI, CLI menu

Page 11

Accessing the pass-thru module CLI locally

1.Using a null-modem mini-USB to DB-9 RS232 serial cable (not included), connect the pass-thru module management port to a local client device (such as a laptop computer).

2.Open a terminal emulation session and set the following parameters:

Parameter

Value

 

 

Baud rate

9600

 

 

Data bits

8

 

 

Parity

None

 

 

Stop bits

1

 

 

Flow control

None

 

 

Production mode CLI

The CLI provides backward and forward cursor control, backward deletion capability, and a 16-line history buffer. There is no tab "auto-completion" feature, but if there is enough information to determine the command to be used, the interface will accept part of the CLI command. For example, entering sys is enough to enter the system menu.

CLI menu

Command

Result

 

 

Main menu

 

 

 

system

Displays System menu.

 

 

port

Displays Port menu.

 

 

System menu

 

 

 

info

Displays system information.

 

 

config

Enables you to set active or factory default configuration.

 

 

dumpconfig

Dumps active configuration.

 

 

reset

Resets pass-thru module.

 

 

Port menu

 

 

 

auto

Displays Port menu auto-negotiation configuration

 

details.

 

 

info

Displays port information.

 

 

Global command

 

 

 

save

Saves configuration.

 

 

Notes:

The port/auto command uses the following format: "/port/auto <uplinkdownlink> <port #> <on/off>". The port number can be a sequence of numbers (e.g., "1 3 5 15") or, if all ports are to be configured, the "*" option can be used (for example, "/port/auto uplink * off" disables auto- negotiation on all uplink ports).

The port/info command displays link configuration and status.

Installing the pass-thru module 11

Image 11
Contents Part Number December 2010 Second Edition 10GbE Pass-Thru Module User GuideIntended audience Contents Electrostatic discharge Pass-thru module architecture FeaturesIntroduction Redundant paths to server bays XModemPort mapping Dual pass-thru modules Description ResetsComponent identification 10GbE Pass-Thru Module front panel Description Module security Installing the pass-thru moduleManually configuring the pass-thru module Installing the moduleAccessing the pass-thru module CLI remotely Accessing the pass-thru module CLICLI menu Accessing the pass-thru module CLI locallyProduction mode CLI Command ResultInstalling SFP+ transceivers Replacing an existing module Replacing a pass-thru moduleMethods for updating the 10GbE Pass-Thru Module firmware Updating the 10GbE pass-thru firmwareEnter y. The following message appears Enter C. The following message appearsEnter R. The following message appears Enter N. The following message appearsEnter x. The following message appears Configuration Script Files Usb//d1/test.cfg Performing a serial firmware image download Updating the firmware image using the serial portBaud rate 9600 Data bits Parity None Stop bits Flow control Additional references For more informationCause Action TroubleshootingHealth LED on the pass-thru module is not on Try another mini-USB to DB-9 RS232 cable Download fails after starting to download the firmware file Pass-thru module configuration is corruptSFP+ transceiver port is disabled Port names Technical specificationsGeneral specifications Category SpecificationMini-USB to DB-9 serial adapter pin assignment Physical and environmental specificationsFrom Wire Shell Braid Technical specifications Regulatory compliance notices Regulatory compliance notices Regulatory compliance notices Grounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Acronyms and abbreviations Local-area network Media Access ControlNetwork access server Power-On Self TestIndex Index