Lennox International Inc CBX32MV06, XP2101, XC2105 Add or Remove Non−communicating equipment

Page 9
Add or Remove Non−communicating equipment

Add or Remove Non−communicating equipment

Figure 7 (previous page) shows how to access the communicating equipment" screen.

Adding Non−Communicating Outdoor unit See figure 8 for details for adding/removing an outdoor unit.

Adding Humidifier The procedures in figure 9 describe adding a non− communicating humidifier which will be controlled by the icomfort Wi-Fit thermostat through the .

Adding Dehumidifier procedures in figure 10 describe adding a non−communicating dehumidifier controlled by the icomfort Wi-Fit thermo- stat through the .

NOTICE

For details about how the humidification and dehumidification modes operate and how to configure those modes, see additional in- formation beginning on Page 18.

HUMIDITY CONTROL TIPS

SThe standard humidification mode is

during a call for heat, if there is a humidification demand).

SSensed outdoor temperature, required for some features, is provided from one of the following sources:

A downloaded via Wi−Fi when available (primary source), B sensor furnished with icomfortt−enabled outdoor units,

C separate outdoor sensor connected to the furnace or air handler sensor" connections.

NOTE − If no source for outdoor temperature is present, Precision Dew Point Control" modes are not available.

SIf you do not have the ability to select or adjust the Humidity RH set-

point on thebutton, the control is set for

Only." In the installer program, go the equipment button and select

and press the

edit button. Select

Mode" and press edit. Choose

Control" or

save.

Adding non−communicating accessories maintenance timer reminders to accessories is a simple process of

which effectively tells the thermostat to activate access to its service timers.

Timers are available for two (2) filters, Humidifier pad, UV bulb maintenance and the PureAirt Air Purification system.

Page 9

icomfort Wi-Fit 7−Day Programmable Communicating Thermostat

Image 9
Contents icomfortt−Enabled Units INSTALLER’S SYSTEM SETUP GUIDE2P0912**P506920-01 CONTROLSSetting up typical icomfortt systems Table of ContentsPage Supports Outdoor Temperature Sensor optionFigure 1. icomfort by Lennoxt system Installation and Setup Figure 3. Settings change tools Change settingsDealer Number Figure 4. EnteringTable 1. System setting defaults and range Circulate fan ON time setting09 39 am Set time and dateFigure 5. View/edit time and date Figure 6. Set current time and dateFigure 7. Using the HUMIDITY CONTROL TIPS Add or Remove Non−communicating equipmentFigure 8. Add non−communicating device Add Non−Communicating Outdoor unitred settings SystemFigure 9. Add or remove non−communicating device 5a 5bSystem HumidifierSystem Figure 10. Add or remove non−communicating deviceDehumidifier DehumidifierFigure 11. Adjust communicating device screens Adjust a setting screen communicating devicesFigure 12. Accessing device to modify Figure 13. Modify device settingsG71MPP or SLP98 Furnace Note Figure 14. Adjust a non−communicating device setting Figure 15. Adjust a non−communicating device setting Figure 16. Adjust dehumidification when not using Humiditrol or an auxiliary dehumidifier Humidification and Dehumidification Modes HUMIDIFICATION modesDEHUMIDIFICATION modes Figure 17. Start testing screen Use the Tests / Diagnostics featuresFigure 18. Select tests to run screen Figure 19. Typical tests results screensSet up Equipment parameters Equipment, Alerts, DiagnosticsFigure 20. Testing finished screen Figure 21. Equipment parameters screenFigure 22. Edit equipment details Run DiagnosticsView and clear Installer Alerts Figure 23. Select device and run diagnosticsView cleared alerts Figure 25. Cleared alert confirmationFigure 24. Selecting and viewing alerts Figure 26. Cleared alerts screenSecure Connection Recommended Figure 27. Wi−Fi setupSTART HERERegistering the icomfort Wi-Fitthermostat Registration for online accessFigure 28. Change Networks Figure 30. icomfort Wi-FitRegistration screen How Do I Upload a Skin? Welcome homeFigure 31. PC Welcome Screen Wi-FitTheryes no Access installer program from Home screenFigure 34. Re−configuration process Reconfigure a system2nd Stage Differential where applicable2 Rules for SSR Smooth Setback Recovery SSRHeat Pump Balance Points Heat Pump, Dual Fuel and Balance PointsLow Balance Point High Balance PointShut down HP Gas Heat Control Mode Figure 36. Variable Capacity Operation Flow ChartTable 2. Variable Capacity Furnace Operation Staged operationLoad−tracking Variable Capacity FAQs SLP98V only Installer entry Table 3. Adjustable Parameters Table InstallerLock in 2nd stage HP by Outdoor Temp Table 3. Adjustable Parameters Table InstallerAIR HANDLER Table 3. Adjustable Parameters Table InstallerGas Heat Airflow Settings Table 3. Adjustable Parameters Table InstallerFURNACE Cooling Airflow Settings Heat Pump Airflow SettingsTable 3. Adjustable Parameters Table Installer Table 3. Adjustable Parameters Table Installer Other ParametersTable 4. Adjustable Parameters Table User Filter 1 Timer Table 5. Alert Codes and Troubleshooting Alert Table 5. Alert Codes and TroubleshootingAlert Table 5. Alert Codes and TroubleshootingAlert Table 5. Alert Codes and TroubleshootingAlert Table 5. Alert Codes and TroubleshootingAlert Table 5. Alert Codes and TroubleshootingAlert Table 5. Alert Codes and TroubleshootingAlert Table 5. Alert Codes and TroubleshootingAlert Table 5. Alert Codes and TroubleshootingTable 5. Alert Codes and Troubleshooting Homeowner Service Alert Codes8Issue / Problem Table 6. Troubleshooting TipsPossible Cause Corrective Action / CommentsHigh Balance Point and Low Bal Table 6. Troubleshooting TipsDetermine the actual Software ver Table 6. Troubleshooting TipsDuring the cooling mode the dis Table 6. Troubleshooting Tipsicomfortt Communicating System Wiring Wiring Diagramsicomfort by Lennoxt AIR HANDLER AHC Wiring Diagramsfor use with any icomfort by Lennoxt system Optional Accessories WiringOptional Accessories Wiring for use with any icomfort by Lennoxt systemLVCS Ventilation Control System attached to the PUSHBUTTON TIPS Setting up typical systemsTIPS Setting up typical systemsT PUMP DUAL FUEL TIPSTIPS TIPS Setting up typical systemsTIPS TIPS Setting up typical systemsT PUMP UNITSTIPS REVISION HISTORY Table 7. Replacement Controlsicomfortt−Enabled Unit Replacement Kit Catalog No