Table 3. Adjustable Parameters Table (Installer)
Parameter Name: | Default | Parameter Value Setting | Increment | Installer entry |
|
|
|
|
|
System (Go to equipment button and scroll to System) NOTE − All of the following changes are made on the stat.
Equipment Name |
| (keyboard input screen) |
|
|
|
|
|
|
|
Filter 1 Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
|
|
Filter 2 Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
|
|
UV Bulb Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
|
|
Humidifier Pad Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
|
|
PureAirt Timer Selection | Calendar Time | Calendar Time, Run Time |
|
|
|
|
|
|
|
Smooth Setback Recovery | Enabled | Enabled, Disabled |
|
|
|
|
|
|
|
Auto Changeover − Temp Deadband | 5ºF | 3 to 9ºF | 1ºF |
|
|
|
|
|
|
Electric Heat Control Mode | Standard | Standard, Even Heat |
|
|
|
|
|
|
|
Gas Heat Control Mode: (SLP98, G71MPP) | Load Tracking | Load Tracking Variable Capacity, Variable Capacity, Staged |
|
|
|
|
|
|
|
(SL280, EL296) | Staged | Staged only |
|
|
|
|
|
|
|
Max Heat Setpoint | 90ºF | 40 to 90ºF | 1ºF |
|
|
|
|
|
|
Min Cool Setpoint | 60ºF | 60 to 99ºF | 1ºF |
|
|
|
|
|
|
Heat Cool Stages Locked In | Disabled | Enabled, Disabled |
|
|
|
|
|
|
|
*1st Stage Differential | 1.0ºF | 0.5 to 3ºF | 0.5ºF |
|
|
|
|
|
|
*2nd Stage Differential | 1.0ºF | 0.5 to 8ºF | 0.5ºF |
|
|
|
|
|
|
*3rd Stage Differential | 0.5ºF | 0.5 to 8ºF | 0.5ºF |
|
|
|
|
|
|
*4th Stage Differential | 0.5ºF | 0.5 to 8ºF | 0.5ºF |
|
|
|
|
|
|
*5th Stage Differential | 0.5ºF | 0.5 to 8ºF | 0.5ºF |
|
|
|
|
|
|
*6th Stage Differential | 0.5ºF | 0.5 to 8ºF | 0.5ºF |
|
|
|
|
|
|
Stage Delay Timers | Enabled | Enabled, Disabled |
|
|
|
|
|
|
|
*2nd Stage Delay | 20 Minutes | 5 to 120 Minutes | 5 Min |
|
|
|
|
|
|
*3rd Stage Delay | 20 Minutes | 5 to 120 Minutes | 5 Min |
|
|
|
|
|
|
*4th Stage Delay | 20 Minutes | 5 to 120 Minutes | 5 Min |
|
|
|
|
|
|
*5th Stage Delay | 20 Minutes | 5 to 120 Minutes | 5 Min |
|
|
|
|
|
|
*6th Stage Delay | 20 Minutes | 5 to 120 Minutes | 5 Min |
|
|
|
|
|
|
*Number of stages shown in thermostat is dependent on equipment that is installed. Electric heat will bring on 2 elements at a time if available.
table continued on next page
Page 37 | icomfort |