Lennox International Inc G71MPP03, XP2101 Other Parameters, Adjustable Parameters Table Installer

Page 42
Other Parameters

Table 3. Adjustable Parameters Table (Installer)

Parameter Name

Default

Min.

Max.

Incr.

Dependency

Note

Installer entry

 

 

 

 

 

 

 

 

Other Parameters

Equipment Name

Furnace

N/A

N/A

N/A

None

Up to 35 characters

 

 

 

 

 

 

 

 

 

Continuous Indoor Blower Airflow

DIP SW (See

Min

Max

25

None

1/2 HP blower

 

 

Note 3 at

CFM

CFM

 

 

 

 

 

end of table)

 

 

 

 

 

 

 

Min

Max

25

 

1 HP blower

 

 

 

 

 

 

 

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

Humidification Airflow

Same as

Min

Max

25

Humidifier present

1/2 HP blower

 

 

above

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

Max

25

 

1 HP blower

 

 

 

CFM

CFM

 

 

 

 

 

 

 

 

 

 

 

 

Dehumidification Airflow Percentage

140

(=70%)

120

160

2

OU present and SC

Percent of High Cooling

(=60%)

(=80%)

(=1%)

(Subnet Controller)

Airflow

 

 

 

algorithm support

 

 

 

 

 

 

Note 1: Minimum Outdoor Unit Cooling Stage as a percentage of High Cooling Airflow (value is rounded up to the closest number on 25 CFM resolution.

Note 2: Minimum Outdoor Unit Heating Stage as a percentage of High Heat Pump Airflow (value is rounded up to the closest number on 25 CFM resolution).

Note 3: All communicating Installer Parameters default CFM values based on DIP switch setting (non−communicating value) are calculated using the CFM conversion tables and rounded up to closest number on 25 CFM resolution.

Note 4: Parameter dependency − Certain parameters are dependent on others and may not be shown on the display.

Note 5: Default Values − Jumper/DIP switches impact the default value of some parameters.

506920−01 09/12

Page 42

Image 42
Contents 2P0912**P506920-01 INSTALLER’S SYSTEM SETUP GUIDEicomfortt−Enabled Units CONTROLSSetting up typical icomfortt systems Table of ContentsPage Supports Outdoor Temperature Sensor optionFigure 1. icomfort by Lennoxt system Installation and Setup Dealer Number Change settingsFigure 3. Settings change tools Figure 4. EnteringCirculate fan ON time setting Table 1. System setting defaults and rangeFigure 5. View/edit time and date Set time and date09 39 am Figure 6. Set current time and dateFigure 7. Using the Add or Remove Non−communicating equipment HUMIDITY CONTROL TIPSred settings Add Non−Communicating Outdoor unitFigure 8. Add non−communicating device SystemSystem 5a 5bFigure 9. Add or remove non−communicating device HumidifierDehumidifier Figure 10. Add or remove non−communicating deviceSystem DehumidifierAdjust a setting screen communicating devices Figure 11. Adjust communicating device screensFigure 12. Accessing device to modify Figure 13. Modify device settingsG71MPP or SLP98 Furnace Note Figure 14. Adjust a non−communicating device setting Figure 15. Adjust a non−communicating device setting Figure 16. Adjust dehumidification when not using Humiditrol or an auxiliary dehumidifier Humidification and Dehumidification Modes HUMIDIFICATION modesDEHUMIDIFICATION modes Figure 18. Select tests to run screen Use the Tests / Diagnostics featuresFigure 17. Start testing screen Figure 19. Typical tests results screensFigure 20. Testing finished screen Equipment, Alerts, DiagnosticsSet up Equipment parameters Figure 21. Equipment parameters screenRun Diagnostics Figure 22. Edit equipment detailsFigure 23. Select device and run diagnostics View and clear Installer AlertsFigure 24. Selecting and viewing alerts Figure 25. Cleared alert confirmationView cleared alerts Figure 26. Cleared alerts screenSTART Figure 27. Wi−Fi setupSecure Connection Recommended HERERegistering the icomfort Wi-Fitthermostat Registration for online accessFigure 28. Change Networks Figure 30. icomfort Wi-FitRegistration screen Figure 31. PC Welcome Screen Welcome homeHow Do I Upload a Skin? Wi-FitTherAccess installer program from Home screen yes noReconfigure a system Figure 34. Re−configuration process2nd Stage Differential where applicable2 Smooth Setback Recovery SSR Rules for SSRLow Balance Point Heat Pump, Dual Fuel and Balance PointsHeat Pump Balance Points High Balance PointShut down HP Figure 36. Variable Capacity Operation Flow Chart Gas Heat Control ModeStaged operation Table 2. Variable Capacity Furnace OperationLoad−tracking Variable Capacity FAQs SLP98V only Table 3. Adjustable Parameters Table Installer Installer entryTable 3. Adjustable Parameters Table Installer Lock in 2nd stage HP by Outdoor TempTable 3. Adjustable Parameters Table Installer AIR HANDLERGas Heat Airflow Settings Table 3. Adjustable Parameters Table InstallerFURNACE Cooling Airflow Settings Heat Pump Airflow SettingsTable 3. Adjustable Parameters Table Installer Other Parameters Table 3. Adjustable Parameters Table InstallerTable 4. Adjustable Parameters Table User Filter 1 Timer Table 5. Alert Codes and Troubleshooting Table 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertHomeowner Service Alert Codes8 Table 5. Alert Codes and TroubleshootingPossible Cause Table 6. Troubleshooting TipsIssue / Problem Corrective Action / CommentsTable 6. Troubleshooting Tips High Balance Point and Low BalTable 6. Troubleshooting Tips Determine the actual Software verTable 6. Troubleshooting Tips During the cooling mode the disWiring Diagrams icomfortt Communicating System WiringWiring Diagrams icomfort by Lennoxt AIR HANDLER AHCOptional Accessories Wiring for use with any icomfort by Lennoxt systemOptional Accessories Wiring for use with any icomfort by Lennoxt systemLVCS Ventilation Control System attached to the PUSHBUTTON Setting up typical systems TIPSTIPS Setting up typical systemsT PUMP DUAL FUEL TIPSTIPS Setting up typical systems TIPSTIPS Setting up typical systemsT PUMP UNITS TIPSTIPS icomfortt−Enabled Unit Table 7. Replacement ControlsREVISION HISTORY Replacement Kit Catalog No