Lennox International Inc XP1702, XP2101, XC2105, XC1702 Adjust a non−communicating device setting

Page 16
Figure 15. Adjust a non−communicating device setting

Adjust a setting... Configure Humiditrol® or Auxiliary Dehumidifier

system devices

 

To adjust a setting,

 

Pre−adjustment REQUIREMENTS:

 

 

 

 

 

 

1st, the device has been installed (see Page 12).

 

System

 

highlight it,

 

 

 

 

about

 

2nd, from the

 

 

 

next.

 

then press Edit

 

 

 

 

 

 

 

 

 

 

Air Conditioner

 

 

 

 

3rd, in the

 

 

 

 

Furnace

 

System

resetAll

1.

In the

 

1a) to highlight System. Press

 

 

 

 

 

 

 

edit (1b).

 

 

 

 

Thermostat

1a

 

 

 

 

 

 

 

2.

Humiditrol® only

 

 

2a) to highlight

Humiditrol

 

1b

edit

 

 

 

 

Humiditrol Comfort Adjust. The current value defaults to Maximum Over-

 

 

 

 

 

 

 

 

 

System

 

 

 

 

cooling. Press edit (2b).

 

 

 

 

Dehumidification Control Mode

3.

Humiditrol® onlyouch one of the radio buttons ( 3a) to select the over-

 

 

3rd Stage Delay

 

 

reinstall

 

cooling level; press save (3b). (After saving, check that the current value

 

 

 

 

4th Stage Delay

 

current value:

 

 

now shows the new selection).

 

 

 

 

 

 

 

 

 

 

 

 

Lock In 2nd Stage HP by Outdoor Temp

 

Midpoint Overcooling

 

4.

Use arrows (4a) to highlight Min Dehumidification Setpoint; press edit

 

 

reset

 

(4b). Note the current value (e.g. 45).

 

 

 

Balance Point Control

2a

 

 

 

 

 

5.

Use arrows (5a) to make changes; press save (5b). (After saving, check

Humiditrol Comfort Adjust

 

 

 

 

 

 

 

that the current value now shows the new selection).

 

 

 

 

 

 

 

Min Dehumidification Setpoint

 

2b

edit

6.

Press the back button to return to

 

 

 

Humiditrol Comfort Adjust

 

 

 

 

 

 

 

Select one

 

 

 

 

 

 

 

 

 

Maximum Overcooling

 

Midpoint Overcooling

 

 

 

 

 

 

 

Minimum Overcooling

 

back

 

 

 

 

 

 

 

 

 

 

Dehumidification Control Mode

 

 

 

 

 

System

 

 

 

 

3a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Staged Delay TImers

 

current value:

 

 

 

 

save

 

cancel

 

 

 

 

 

3b

 

2nd Stage Delay

 

45

 

 

 

 

 

 

 

 

 

 

Min Dehumidification Setpoint

 

 

3rd Stage Delay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range is 40 to 60

 

 

4th Stage Delay

4a

 

 

4b

 

 

 

 

 

 

 

 

Default is 45, inc:1

Humiditrol Comfort Adjust settings are

Lock In 2nd Stage HP by Outdoor Temp

 

 

edit

 

only available on units equipped with

 

 

 

 

set−to

 

 

Balance Point Control

 

 

 

 

 

 

a Humiditrol® dehumidification device.

 

 

 

 

 

 

 

 

 

 

 

 

5a

See Page 18 for description of Min/

 

Humiditrol Comfort Adjust

 

 

 

reset

 

42

Mid/Max overcooling.

 

 

 

 

 

 

 

 

Min Dehumidification Setpoint

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OD/Humid Boundary

 

 

 

(returns to

5b

save

cancel

 

 

Outdoor Temperature Reading Calibr

 

back

 

 

 

 

 

adjust a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

 

9:39 am Aug 15, 2012

 

 

screen)

 

 

 

 

 

 

 

 

 

 

 

Figure 15. Adjust a non−communicating device setting

506920−01 09/12

Page 16

Image 16
Contents INSTALLER’S SYSTEM SETUP GUIDE icomfortt−Enabled Units2P0912**P506920-01 CONTROLSTable of Contents Setting up typical icomfortt systemsPage Outdoor Temperature Sensor option SupportsFigure 1. icomfort by Lennoxt system Installation and Setup Change settings Figure 3. Settings change toolsDealer Number Figure 4. EnteringCirculate fan ON time setting Table 1. System setting defaults and rangeSet time and date 09 39 amFigure 5. View/edit time and date Figure 6. Set current time and dateFigure 7. Using the Add or Remove Non−communicating equipment HUMIDITY CONTROL TIPSAdd Non−Communicating Outdoor unit Figure 8. Add non−communicating devicered settings System5a 5b Figure 9. Add or remove non−communicating deviceSystem HumidifierFigure 10. Add or remove non−communicating device SystemDehumidifier DehumidifierAdjust a setting screen communicating devices Figure 11. Adjust communicating device screensFigure 13. Modify device settings Figure 12. Accessing device to modifyG71MPP or SLP98 Furnace Note Figure 14. Adjust a non−communicating device setting Figure 15. Adjust a non−communicating device setting Figure 16. Adjust dehumidification when not using Humiditrol or an auxiliary dehumidifier HUMIDIFICATION modes Humidification and Dehumidification ModesDEHUMIDIFICATION modes Use the Tests / Diagnostics features Figure 17. Start testing screenFigure 18. Select tests to run screen Figure 19. Typical tests results screensEquipment, Alerts, Diagnostics Set up Equipment parametersFigure 20. Testing finished screen Figure 21. Equipment parameters screenRun Diagnostics Figure 22. Edit equipment detailsFigure 23. Select device and run diagnostics View and clear Installer AlertsFigure 25. Cleared alert confirmation View cleared alertsFigure 24. Selecting and viewing alerts Figure 26. Cleared alerts screenFigure 27. Wi−Fi setup Secure Connection RecommendedSTART HERERegistration for online access Registering the icomfort Wi-FitthermostatFigure 28. Change Networks Figure 30. icomfort Wi-FitRegistration screen Welcome home How Do I Upload a Skin?Figure 31. PC Welcome Screen Wi-FitTherAccess installer program from Home screen yes noReconfigure a system Figure 34. Re−configuration process2nd Stage Differential where applicable2 Smooth Setback Recovery SSR Rules for SSRHeat Pump, Dual Fuel and Balance Points Heat Pump Balance PointsLow Balance Point High Balance PointShut down HP Figure 36. Variable Capacity Operation Flow Chart Gas Heat Control ModeStaged operation Table 2. Variable Capacity Furnace OperationLoad−tracking Variable Capacity FAQs SLP98V only Table 3. Adjustable Parameters Table Installer Installer entryTable 3. Adjustable Parameters Table Installer Lock in 2nd stage HP by Outdoor TempTable 3. Adjustable Parameters Table Installer AIR HANDLERTable 3. Adjustable Parameters Table Installer Gas Heat Airflow SettingsFURNACE Heat Pump Airflow Settings Cooling Airflow SettingsTable 3. Adjustable Parameters Table Installer Other Parameters Table 3. Adjustable Parameters Table InstallerTable 4. Adjustable Parameters Table User Filter 1 Timer Table 5. Alert Codes and Troubleshooting Table 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertTable 5. Alert Codes and Troubleshooting AlertHomeowner Service Alert Codes8 Table 5. Alert Codes and TroubleshootingTable 6. Troubleshooting Tips Issue / ProblemPossible Cause Corrective Action / CommentsTable 6. Troubleshooting Tips High Balance Point and Low BalTable 6. Troubleshooting Tips Determine the actual Software verTable 6. Troubleshooting Tips During the cooling mode the disWiring Diagrams icomfortt Communicating System WiringWiring Diagrams icomfort by Lennoxt AIR HANDLER AHCOptional Accessories Wiring for use with any icomfort by Lennoxt systemfor use with any icomfort by Lennoxt system Optional Accessories WiringLVCS Ventilation Control System attached to the PUSHBUTTON Setting up typical systems TIPSTIPS TIPS Setting up typical systemsT PUMP DUAL FUELTIPS Setting up typical systems TIPSTIPS Setting up typical systemsT PUMP UNITS TIPSTIPS Table 7. Replacement Controls REVISION HISTORYicomfortt−Enabled Unit Replacement Kit Catalog No