Raypak 133-4001 manual Contents

Page 3

CONTENTS

WARNINGS

4

Filling System - Heating Boilers

25

Pay Attention to These Terms

4

Ethylene Glycol Systems -

 

MODEL IDENTIFICATION

5

Heating Boilers

25

RECEIVING EQUIPMENT

6

Initial Start-Up - Pump And Motor

25

CERTIFICATIONS

6

For Models with Automatic Gas Valves

28

BOILER TYPES

6

After Start-Up

28

Type H1 - Mechanical Modulating

6

Standing Pilot Checkout

 

Type H2 - Motorized Modulating

6

Procedure

28

Type H3 - 2-Stage Controls

6

Intermittent Pilot System

 

Type H4 - On-Off Controls

6

Checkout (S8600)

28

Type H5 - Mechanical Modulating

6

Inspections

29

Type H9 - 4-Stage

6

Burners

29

INSTALLATION

6

Controls

29

Installation Codes

6

Suggested Inspection Schedule

29

Installation Base

7

LOW NOx BOILERS

30

Clearances

7

Models 181 to 401

30

Outdoor Boilers

8

Operation

30

High-Wind Conditions (Outdoor Units Only)8

Start-Up (S8600M)

30

Combustion and Ventilation Air

 

Blower Adjustment

30

(Indoor Units Only)

8

Visual Inspection

30

Venting

9

Electrical

30

Indoor Installations

10

Flame Roll-Out Safety Switch

31

Vent Piping

13

Service

31

Vent Damper Installation

15

Burner Tray Removal

31

Plumbing

16

Gas Valve Removal

31

Gas Supply Connections

16

Main Burner and Orifice Removal

31

CONTROLS

21

Pilot Removal

32

Economaster Controls

21

Combustion Fan Removal

32

Electronic Ignition

21

TROUBLESHOOTING

33

Operating Controls

21

Service

38

Limit Controls

23

Repair Section

38

ELECTRICAL CONNECTIONS

24

REPLACEMENT PARTS

41

START-UP

25

WARRANTY

42

Before Start-Up

25

 

 

General

25

 

 

3

Image 3
Contents Raytherm Heating Boilers Deletions None Contents Are important but not related to personal injury hazards 0 5 1 4 a Model IdentificationBoiler Types InstallationReceiving Equipment CertificationsClearances Installation BaseOutdoor Boilers High-Wind Conditions Outdoor Units OnlyCombustion and Ventilation Air Indoor Units Only Model Sq. Inches Outdoor Installations ModelVenting Models 181-401Models Indoor InstallationsIndoor Installation-Model Indoor Stack InstallationIndoor Installation-Models 181-401 Vent Piping Drafthood Installation-ModelsCommon Venting Models 133 Through 261 Where Required Location Vent Damper InstallationNormal Operation Summary PlumbingGas Supply Connections Vent DamperPump Selection Venting of Diaphragm Gas ComponentsGas Pressure Regulator GeneralFeedwater Regulator Temperature & Pressure GaugeRecommended Purge Manifolds for Typical Hydronic System HookupsSingle Boiler Primary/Secondary Piping-Models Multiple-Boiler- Reverse Return Hook-Up-Models Operating Controls ControlsEconomaster Controls Electronic IgnitionMode H9 4-Stage Firing Mode H2 Motorized ModulationMode H3 2-Stage Firing Mode H4 On/Off Firing100% Pilot Safety Manual-Reset High LimitAuto-Reset High Limit Flow SwitchHigh and Low Gas Pressure Switches Optional Electrical ConnectionsLow Water Cut-Off Optional START-UP START-UP For Models with Manual Gas Valves For Your Safety Read Before OperatingLighting Instructions After Start-Up Standing Pilot Checkout ProcedureFor Models with Automatic Gas Valves Intermittent Pilot System Checkout S8600Inspections Burners ControlsSuggested Inspection Schedule Start-Up S8600H Blower AdjustmentModels 181 to OperationService Burner Tray Removal Flame Roll-Out Safety SwitchCombustion Fan Removal Gas Valve RemovalMain Burner and Orifice Removal Pilot RemovalTroubleshooting Electrical-Electronic Ignition IIDIntermittent Pilot System Honeywell S8600 Electrical-Standing Pilot Typical ON-OFF Intermittent Ignition Control Wiring Diagram Mechanical Problem Possible Cause Corrective Action Pumps Gas Valve Removal Service Repair SectionTube Cleaning Procedure Burner Tray RemovalPilot Removal and Cleaning High Limit or Tankstat RemovalHeat Exchanger Removal Combustion Chamber Removal Heat Exchanger Re-AssemblyControl Well Replacement Tube Replacement ProcedureReplacement Parts Cleaning Flue Gas PassagewaysEastman Avenue Oxnard, CA Limited Warranty Raytherm Types H and WH

133-4001 specifications

Raypak 133-4001 is a premier heating solution designed for both residential and commercial applications, known for its efficiency and reliability. This high-performance water heater is specifically engineered to meet the demanding requirements of hot water supply while ensuring energy conservation and user convenience.

One of the standout features of the Raypak 133-4001 is its robust construction. Made from high-quality materials, including a corrosion-resistant heat exchanger and durable casing, this unit is designed to withstand harsh environmental conditions. Its compact design allows for easy installation in various locations, making it an ideal choice for homeowners and businesses alike.

The unit operates on natural gas or LP gas, providing versatility in fuel choice. With a heating capacity of 199,000 BTU/hr, it delivers an impressive flow rate that ensures a steady supply of hot water, even during peak demand periods. This capacity makes it suitable for a wide range of applications, from residential water heating to larger facilities requiring substantial hot water output.

Raypak’s advanced technology set ensures that the 133-4001 operates at maximum efficiency. It utilizes a modulating power burner that adjusts the flame based on demand, optimizing fuel consumption. This feature not only helps in reducing energy bills but also minimizes the carbon footprint, making it an environmentally friendly option.

Another notable characteristic of the Raypak 133-4001 is its digital control system. The intuitive interface allows for precise temperature adjustments and easy monitoring of the heating process. Users can set the desired water temperature, and the system will maintain it consistently, ensuring comfort and reducing the risk of scalding.

Safety is a paramount consideration in the design of the 133-4001. It features a built-in high-limit switch, pressure relief valve, and multiple safety sensors to prevent overheating and potential hazards. These safety features provide peace of mind for homeowners and facility managers, knowing that their hot water system is reliable and secure.

In conclusion, Raypak 133-4001 combines advanced technology, robust construction, and user-friendly features, making it a highly effective water heating solution. Its efficiency and dependability cater to a variety of hot water needs, positioning it as a top choice for both residential and commercial use. Whether for a single-family home or a large facility, the Raypak 133-4001 is built to deliver exceptional performance with every use.