Raypak 133-4001 manual Indoor Installations, Models

Page 10

1.Remove jacket top panel.

2.Remove and discard inner stack adapter panel.

3.

Install jacket top panel.

JACKET TOP

4.

Insert tabs of outdoor top into keyholes located on

 

 

jacket top panel (4 places). See Detail A.

 

5.

Snap tabs on outdoor top into the locked position

 

 

of the keyhole so the top will not pull out. See

FASTENING

 

Detail B.

SCREW

Detail A

Detail B

Outdoor Top

(Shipped Loose with Heater)

Fig. 6: Installing Outdoor Top—Models 181-401 & 182-

400

Models 514-824

1.Lower outdoor top onto unit. Position top so it is centered on unit from side to side and front to rear.

Fig. 8: Installing Outdoor Top Detail—Models 514–824

Models 926-1758

Boilers are shipped with outdoor vent terminal factory installed.

Indoor Installations

Model 133

1.Shut-off main electrical power switch to boiler.

2.Turn heater manual switch located in upper control panel to the "OFF" position.

3.Shut-off gas supply and water supply to the boiler.

4.Mount drafthood on boiler and attach with the sheet metal screws provided. Drafthood should be positioned with the vent sensor located on the front left side (see next page).

5.Remove plastic plug from left side of boiler jacket and install the plastic grommet provided.

6.Route flue sensor wire harness through the grom- met installed in Step 5.

7.Remove door and locate wire from roll-out sensor to high limit with the male/female connector.

8.Disconnect male/female connector and attach to the 2 wires from drafthood vent sensor harness.

Fig. 7: Installing Outdoor Top—Models 514–824

2.Tighten the (4) screws (as indicated in Fig. 8) until they come in contact with the unit jacket top, then evenly tighten all (4) screws to secure to unit.

10

Image 10
Contents Raytherm Heating Boilers Deletions None Contents Are important but not related to personal injury hazards Model Identification 0 5 1 4 aCertifications InstallationReceiving Equipment Boiler TypesInstallation Base ClearancesHigh-Wind Conditions Outdoor Units Only Outdoor BoilersCombustion and Ventilation Air Indoor Units Only Models 181-401 Outdoor Installations ModelVenting Model Sq. InchesIndoor Installations ModelsIndoor Stack Installation Indoor Installation-ModelIndoor Installation-Models 181-401 Drafthood Installation-Models Vent PipingCommon Venting Vent Damper Installation Models 133 Through 261 Where Required LocationVent Damper PlumbingGas Supply Connections Normal Operation SummaryGeneral Venting of Diaphragm Gas ComponentsGas Pressure Regulator Pump SelectionTypical Hydronic System Hookups Temperature & Pressure GaugeRecommended Purge Manifolds for Feedwater RegulatorSingle Boiler Primary/Secondary Piping-Models Multiple-Boiler- Reverse Return Hook-Up-Models Electronic Ignition ControlsEconomaster Controls Operating ControlsMode H4 On/Off Firing Mode H2 Motorized ModulationMode H3 2-Stage Firing Mode H9 4-Stage FiringFlow Switch Manual-Reset High LimitAuto-Reset High Limit 100% Pilot SafetyElectrical Connections High and Low Gas Pressure Switches OptionalLow Water Cut-Off Optional START-UP START-UP For Your Safety Read Before Operating For Models with Manual Gas ValvesIntermittent Pilot System Checkout S8600 After Start-Up Standing Pilot Checkout ProcedureFor Models with Automatic Gas Valves Lighting InstructionsControls Inspections BurnersSuggested Inspection Schedule Operation Blower AdjustmentModels 181 to Start-Up S8600HFlame Roll-Out Safety Switch Service Burner Tray RemovalPilot Removal Gas Valve RemovalMain Burner and Orifice Removal Combustion Fan RemovalElectrical-Electronic Ignition IID TroubleshootingIntermittent Pilot System Honeywell S8600 Electrical-Standing Pilot Typical ON-OFF Intermittent Ignition Control Wiring Diagram Mechanical Problem Possible Cause Corrective Action Pumps Burner Tray Removal Service Repair SectionTube Cleaning Procedure Gas Valve RemovalHigh Limit or Tankstat Removal Pilot Removal and CleaningHeat Exchanger Removal Tube Replacement Procedure Heat Exchanger Re-AssemblyControl Well Replacement Combustion Chamber RemovalCleaning Flue Gas Passageways Replacement PartsEastman Avenue Oxnard, CA Limited Warranty Raytherm Types H and WH

133-4001 specifications

Raypak 133-4001 is a premier heating solution designed for both residential and commercial applications, known for its efficiency and reliability. This high-performance water heater is specifically engineered to meet the demanding requirements of hot water supply while ensuring energy conservation and user convenience.

One of the standout features of the Raypak 133-4001 is its robust construction. Made from high-quality materials, including a corrosion-resistant heat exchanger and durable casing, this unit is designed to withstand harsh environmental conditions. Its compact design allows for easy installation in various locations, making it an ideal choice for homeowners and businesses alike.

The unit operates on natural gas or LP gas, providing versatility in fuel choice. With a heating capacity of 199,000 BTU/hr, it delivers an impressive flow rate that ensures a steady supply of hot water, even during peak demand periods. This capacity makes it suitable for a wide range of applications, from residential water heating to larger facilities requiring substantial hot water output.

Raypak’s advanced technology set ensures that the 133-4001 operates at maximum efficiency. It utilizes a modulating power burner that adjusts the flame based on demand, optimizing fuel consumption. This feature not only helps in reducing energy bills but also minimizes the carbon footprint, making it an environmentally friendly option.

Another notable characteristic of the Raypak 133-4001 is its digital control system. The intuitive interface allows for precise temperature adjustments and easy monitoring of the heating process. Users can set the desired water temperature, and the system will maintain it consistently, ensuring comfort and reducing the risk of scalding.

Safety is a paramount consideration in the design of the 133-4001. It features a built-in high-limit switch, pressure relief valve, and multiple safety sensors to prevent overheating and potential hazards. These safety features provide peace of mind for homeowners and facility managers, knowing that their hot water system is reliable and secure.

In conclusion, Raypak 133-4001 combines advanced technology, robust construction, and user-friendly features, making it a highly effective water heating solution. Its efficiency and dependability cater to a variety of hot water needs, positioning it as a top choice for both residential and commercial use. Whether for a single-family home or a large facility, the Raypak 133-4001 is built to deliver exceptional performance with every use.