Rinnai RHFE-750ETRA installation manual Care and Maintenance, Filters, Visual Inspection of Flame

Page 11

Care and Maintenance

Maintenance

Repairs should be performed by a qualified service technician. The appliance should be inspected annually by a qualified service agency.

More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passage ways of the appliance be kept clean.

When the appliance has cooled off, gain access by removing the front panel, combustion chamber glass panel, and ceramic logs. Refer to the Parts List and the sections Cleaning Combustion Chamber Glass and Final Assembly for disassembly / assembly instructions. Vacuum, use pressurized air, and then vacuum again to remove dust from the burners, compartments, and convection fan.

Any filter or guard removed for servicing the appliance must be replaced prior to operating the appliance.

The vent should be inspected annually for blockages or damage.

Motors are permanently lubricated and do not need periodic lubrication. Keep fan and motor free of dust and dirt by cleaning annually.

Verify proper operation after servicing.

Filters

This appliance has two filters which are behind the louvers on either side of the heater. The louvers are hinged to allow access to the filters.

Dirty filters reduce the air flow and the appliance’s

ability to produce heat. The filters should be cleaned once a week during the heating season. If the filters become blocked the blockage indicator will flash red. The filters should be cleaned whenever the blockage indicator flashes red. If not cleaned the appliance may turn off and display fault code 14 (overheat) on the control panel display.

To clean the filters, the appliance should be OFF and cool. Open the louver by pushing inward and releasing. Slide the filter upwards until the bottom tab clears the lower retaining slot. Then slide the filter down and away to remove. Clean the filter using a soft dry cloth or vacuum.

Visual Inspection of Flame

Check that the pilot and burner flames are operating normally.

If flames appear either very short or very long and streaky or are producing smoke or soot deposits then there may be a problem with the appliance or gas supply.

The appliance should not be used if you suspect there is a problem. Call a qualified service technician to inspect the appliance.

The burners are designed to produce two rows of yellow flame but not smoke or soot.

NORMAL

 

ABNORMAL

Rinnai Corporation RHFE-750ETRA

11

Image 11
Contents RHFE-750ETRA Table of Contents Safety Behavior and Practices Safety Features Natural Gas Propane Gas SpecificationsDimensions FeaturesDescription Part Number Front PanelFront Panel Models Remote Control Care Remote Control FeaturesTurning on and OFF Remote Control OperationSequence of Operations Basic Fireplace OperationsLock Function Adjusting the TemperatureFlame Function Obstruction of Warm Air DischargePre-heat TimersProgramming the clock and timers Using the OverrideVisual Inspection of Flame Care and MaintenanceMaintenance FiltersCare of Exterior Cleaning Combustion Chamber GlassProblem Possible Solutions or Explanation TroubleshootingCode Fault Remedy Fault CodesReplacement of Thermal Fuse General Instructions Parts Included for InstallationClearances for a Mantle or Decorative Overhang Clearances to CombustiblesFlue Terminal Clearances Side clearances for air ventsDescription Canadian Installations US Installations 28.3 in 720 mm LocationCorrect Floor Drilling Flue and Gas Supply Holes Flue Manifold InstallationVenting Venting with Flue Manifolds FOT-203 and FOT-204+ c II. Extended Venting Horizontal and Vertical Terminations Maximum Length = 33 feet 10 m and 3 elbows Manufacturer Metal-FabPart Description Number Additional Venting Clearances Vent Length SwitchConnections Mounting points Install the Logs Final AssemblyCondensate Tray Air Guide Vanes Install the Front PanelOperating Instructions For Your Safety Read Before OperatingWiring and Schematic Diagrams Parts List Parts List 109 QTY Description Comments NG Left and Right Packing for AIR Inlet BOX RHFE-750ETRA Direct Vent Fireplace Warranty InformationLimited Warranty What is covered?Limitation on warranties How do I get service? What is not covered?What will Rinnai do? Issue G