Flue Terminal Clearances

Ref

Description

Canadian Installations

US Installations

 

 

 

 

 

Clearance above grade, veranda, porch,

 

 

A

deck, or balcony. (Take into account the

12 inches (30 cm)

12 inches (30 cm)

 

anticipated snow line.)

 

 

 

 

 

 

B

Clearance to window or door that may be

12 inches (30 cm)

9 inches (23 cm)

opened

 

 

 

C

Clearance to permanently closed window

*

*

 

 

 

 

 

Vertical clearance to ventilated soffit,

 

 

D

located above the terminal within a

*

*

horizontal distance of 2 feet (61 cm) from

 

 

 

 

the center line of the terminal

 

 

 

 

 

 

E

Clearance to unventilated soffit

*

*

 

 

 

 

F

Clearance to outside corner

*

*

 

 

 

 

G

Clearance to inside corner

*

*

 

 

 

 

 

 

3 feet (91 cm) within a

 

H

Clearance to each side of center line

height 15 feet (4.57 m)

*

extended above meter/regulator assembly

above the meter/

 

 

 

 

regulator assembly

 

 

 

 

 

I

Clearance to service regulator vent outlet

3 feet (91 cm)

*

 

 

 

 

 

Clearance to nonmechanical air supply

 

 

J

inlet to building or the combustion air inlet

12 inches (30 cm)

9 inches (23 cm)

 

to any other appliance

 

 

 

 

 

 

 

 

 

3 feet (91 cm) above if

K

Clearance to a mechanical air supply inlet

6 feet (1.83 m)

within 10 feet (3 m)

 

 

 

horizontally

L

Clearance above paved sidewalk or

7 feet (2.13 m) 1

*

paved driveway located on public property

 

 

 

M

Clearance under veranda, porch, deck, or

12 inches (30 cm) 2

*

balcony

 

 

 

 

 

 

 

1A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

2Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

*For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, clearances are in accordance with local installation codes and the requirements of the gas supplier.

Rinnai Corporation RHFE-750ETRA

17

Image 17
Contents RHFE-750ETRA Table of Contents Safety Behavior and Practices Safety Features Natural Gas Propane Gas SpecificationsDimensions FeaturesDescription Part Number Front PanelFront Panel Models Remote Control Care Remote Control FeaturesSequence of Operations Remote Control OperationBasic Fireplace Operations Turning on and OFFFlame Function Adjusting the TemperatureObstruction of Warm Air Discharge Lock FunctionProgramming the clock and timers TimersUsing the Override Pre-heatMaintenance Care and MaintenanceFilters Visual Inspection of FlameCare of Exterior Cleaning Combustion Chamber GlassProblem Possible Solutions or Explanation TroubleshootingCode Fault Remedy Fault CodesReplacement of Thermal Fuse General Instructions Parts Included for InstallationFlue Terminal Clearances Clearances to CombustiblesSide clearances for air vents Clearances for a Mantle or Decorative OverhangDescription Canadian Installations US Installations 28.3 in 720 mm LocationCorrect Floor Venting Flue Manifold InstallationVenting with Flue Manifolds FOT-203 and FOT-204 Drilling Flue and Gas Supply Holes+ c II. Extended Venting Horizontal and Vertical Terminations Maximum Length = 33 feet 10 m and 3 elbows Manufacturer Metal-FabPart Description Number Additional Venting Clearances Vent Length SwitchConnections Mounting points Install the Logs Final AssemblyCondensate Tray Air Guide Vanes Install the Front PanelOperating Instructions For Your Safety Read Before OperatingWiring and Schematic Diagrams Parts List Parts List 109 QTY Description Comments NG Left and Right Packing for AIR Inlet BOX Limited Warranty Warranty InformationWhat is covered? RHFE-750ETRA Direct Vent FireplaceLimitation on warranties How do I get service? What is not covered?What will Rinnai do? Issue G