Rinnai RHFE-750ETRA installation manual Safety Behavior and Practices Safety Features

Page 3

Safety Behavior and Practices

Safety Features

Overheat: The appliance will automatically shut down when the appliance exceeds a predetermined temperature.

Flame Failure: The appliance will automatically shut down if the burner flame is extinguished.

Power Failure: The appliance will cut off the gas if it loses electrical power.

Power Surge Fuse: A glass fuse power supply harness protects against overcurrent. If the fuse blows then all indicator lamps will be off.

Spark Detector: The appliance automatically shuts down if there is an abnormal spark at ignition.

Rinnai Corporation RHFE-750ETRA

3

Image 3
Contents RHFE-750ETRA Table of Contents Safety Behavior and Practices Safety Features Natural Gas Propane Gas SpecificationsDimensions FeaturesFront Panel Front Panel ModelsDescription Part Number Remote Control Care Remote Control FeaturesTurning on and OFF Remote Control OperationSequence of Operations Basic Fireplace OperationsLock Function Adjusting the TemperatureFlame Function Obstruction of Warm Air DischargePre-heat TimersProgramming the clock and timers Using the OverrideVisual Inspection of Flame Care and MaintenanceMaintenance FiltersCare of Exterior Cleaning Combustion Chamber GlassProblem Possible Solutions or Explanation TroubleshootingFault Codes Replacement of Thermal FuseCode Fault Remedy General Instructions Parts Included for InstallationClearances for a Mantle or Decorative Overhang Clearances to CombustiblesFlue Terminal Clearances Side clearances for air ventsDescription Canadian Installations US Installations 28.3 in 720 mm LocationCorrect Floor Drilling Flue and Gas Supply Holes Flue Manifold InstallationVenting Venting with Flue Manifolds FOT-203 and FOT-204+ c II. Extended Venting Horizontal and Vertical Terminations Manufacturer Metal-Fab Part Description NumberMaximum Length = 33 feet 10 m and 3 elbows Additional Venting Clearances Vent Length SwitchConnections Mounting points Install the Logs Final AssemblyCondensate Tray Air Guide Vanes Install the Front PanelOperating Instructions For Your Safety Read Before OperatingWiring and Schematic Diagrams Parts List Parts List 109 QTY Description Comments NG Left and Right Packing for AIR Inlet BOX RHFE-750ETRA Direct Vent Fireplace Warranty InformationLimited Warranty What is covered?How do I get service? What is not covered? What will Rinnai do?Limitation on warranties Issue G