| Specifications |
|
| |||
|
|
|
|
|
|
|
|
|
Application | Vented gas fireplace heater; Inbuilt only; for residential installation, commer- | |||||||
|
| cial setting, or manufactured home; not designed for installation in a | ||||||
|
| burning fireplace |
|
|
|
| ||
|
|
|
|
|
| |||
Certification | CSA certified according to ANSI Z21.88, CSA 2.33 | |||||||
|
|
|
|
|
| |||
General Description | Inbuilt convector, glass and steel fronted, ceramic log space heater with | |||||||
|
| forced convection and power flue system |
|
| ||||
|
|
|
|
|
|
| ||
Operation | Push button electronic / remote control |
|
| |||||
|
|
|
|
|
|
| ||
Gas Connection | Flex line is 3/8 inch flare nut; |
|
| |||||
|
| ball valve is 1/2 inch female x 3/8 inch flare |
|
| ||||
|
|
|
|
|
|
|
|
|
Gas Control | Electronic |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Burners | Flame burners |
|
|
|
| |||
|
|
|
|
|
|
|
| |
Temperature Control | Electronic thermostat |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Logs | Ceramic |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
Ignition System | Electronic spark ignition |
|
| |||||
|
|
|
|
|
| |||
Flue System | The flue must be terminated to atmosphere. Only flue components listed with | |||||||
|
| the appliance’s certification can be used. Warranty will be voided if | ||||||
|
| components are installed. |
|
| ||||
|
|
|
|
|
|
|
| |
Electrical Connection | AC 120V, 60 Hz |
|
|
|
| |||
|
|
|
|
|
|
|
| |
Fan | (134 to 212 CFM) |
|
|
|
| |||
|
|
|
|
|
|
|
| |
Weight | 150 lb (68 kg) |
|
|
|
| |||
|
|
|
|
|
|
| ||
AFUE | 79% NG; | 81% LP (up to 83% with extended vent of 7.2 ft [2.2 m] and no | ||||||
|
| elbows) |
|
|
|
|
| |
Venting | Twin flue: maximum 6.5 ft with 2 elbows |
|
| |||||
|
| Concentric: maximum 33 ft with 3 elbows |
|
| ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
| Natural Gas |
| Propane Gas |
| |
|
|
|
|
|
|
| ||
| Minimum supply gas pressure |
| 4.3 in (109 mm) W.C. |
| 9.8 in (249 mm) W.C. |
| ||
|
|
|
|
|
|
| ||
| Maximum supply gas pressure |
| 10.5 in (267 mm) W.C. |
| 13.0 in (330 mm) W.C. |
| ||
|
|
|
|
|
|
| ||
| Manifold test pressure |
| Factory Set |
| Factory Set |
| ||
|
|
|
|
|
|
| ||
| BTU/hour input |
| Natural Gas: | Low - 11,000 BTU/h; High - 29,000 BTU/h |
| |||
|
|
| Propane: | Low - 11,000 BTU/h; High - 28,000 BTU/h |
| |||
| BTU/hour output |
| Natural Gas: | Low - 8,635 BTU/h; High - 21,900 BTU/h |
| |||
|
|
| Propane: | Low - 8,855 BTU/h; High - 21,840 BTU/h |
|
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.
4 | Rinnai Corporation |