Rinnai RHFE-750ETRA installation manual Location, 28.3 in 720 mm

Page 18

Location

This appliance has a cool outer casing that allows it to be installed in a recessed application consisting of combustible materials such as wood and plaster.

The location needs to have a level surface that allows the appliance to be rolled in or out of the enclosure.

If the surface is elevated and there is not enough room for it to be rolled out then a base and joists may be used as shown.

The appliance will have to be rolled out for maintenance. After installation do not place any permanent fixtures that would prevent pulling the appliance out for access. To pull the appliance completely out of the enclosure a minimum of 15 inches from the front panel would be needed.

LEFT

RIGHT

WHEEL

WHEEL

JOIST

JOIST

28.3 in (720 mm)

Do not vent the exhaust into ‘natural draft’ flue pipes or a chimney flue.

The enclosure must be within these limits:

 

 

Enclosure Dimensions

 

 

 

 

 

Width (w)

 

33.8 in (860 mm)

 

 

 

 

 

 

Height

(h)

 

26.0 - 26.2 in (660-665 mm)

h

 

 

 

 

Depth

(d)

 

15.0 - 16.9 in (380-430 mm)

NOTE: These are minimum clearances.

The front panel extends below the surface on which the appliance rests. Ensure that clearance is maintained in order to install the front panel.

w

d

For installation in the corner of the room refer to the diagram at the right and the table below for dimensions. These dimensions are the minimum required if using the minimum width, height, and depth dimensions above.

Enclosure Dimensions in a Corner

x63.8 in (1620 mm)

y45.1 in (1146 mm)

z31.9 in (810 mm)

x

z

y

18

Rinnai Corporation RHFE-750ETRA

Image 18
Contents RHFE-750ETRA Table of Contents Safety Behavior and Practices Safety Features Specifications Natural Gas Propane GasFeatures DimensionsFront Panel Front Panel ModelsDescription Part Number Remote Control Features Remote Control CareBasic Fireplace Operations Remote Control OperationSequence of Operations Turning on and OFFObstruction of Warm Air Discharge Adjusting the TemperatureFlame Function Lock FunctionUsing the Override TimersProgramming the clock and timers Pre-heatFilters Care and MaintenanceMaintenance Visual Inspection of FlameCleaning Combustion Chamber Glass Care of ExteriorTroubleshooting Problem Possible Solutions or ExplanationFault Codes Replacement of Thermal FuseCode Fault Remedy Parts Included for Installation General InstructionsSide clearances for air vents Clearances to CombustiblesFlue Terminal Clearances Clearances for a Mantle or Decorative OverhangDescription Canadian Installations US Installations Location 28.3 in 720 mmCorrect Floor Venting with Flue Manifolds FOT-203 and FOT-204 Flue Manifold InstallationVenting Drilling Flue and Gas Supply Holes+ c II. Extended Venting Horizontal and Vertical Terminations Manufacturer Metal-Fab Part Description NumberMaximum Length = 33 feet 10 m and 3 elbows Vent Length Switch Additional Venting ClearancesConnections Mounting points Final Assembly Install the LogsCondensate Tray Install the Front Panel Air Guide VanesFor Your Safety Read Before Operating Operating InstructionsWiring and Schematic Diagrams Parts List Parts List 109 QTY Description Comments NG Left and Right Packing for AIR Inlet BOX What is covered? Warranty InformationLimited Warranty RHFE-750ETRA Direct Vent FireplaceHow do I get service? What is not covered? What will Rinnai do?Limitation on warranties Issue G