Operating the Pump Motor in the STOPPED Display Mode

5

 

 

5.6 Measuring the Temperature of a Fluid

TEMP

Display shows

xxx °C

ACTION

Display alternates

when the button is

pressed; °C then °F

then back to °C

The TEMP key displays the temperature of the fluid, as measured via an optional Type K thermocouple probe. The pump motor is equipped with an SMP Type K female thermocouple jack, located near the bottom on the back of the pump motor.

1.To measure the temperature of the fluid, plug one end of an optional Type K thermocouple probe (equipped with an SMP male connector) into the SMP jack and immerse the other end of the probe in the fluid.

2.Press the TEMP key. The display shows the fluid’s temperature in (°F or °C).

3.If you are reading the temperature in °F and wish to switch to °C (or if you are reading the temperature in °C and wish to switch to °F), press the TEMP key again. The display shows the fluid's temperature in the unit of measure to which you switched.

NOTE

If the optional thermocouple probe is not connected to the pump motor, the reading on the display will be 300°F (149°C).

5.7 Preparing for Pumping in a Specific Mode

There are four specific modes in which to pump fluid: RPM, FLOW RATE, TIME, and TOTAL VOLUME. These modes correspond to the criteria the pump motor uses to dispense the fluid. These four modes are described on the next page.

NOTE

When you press the START/STOP key and the pump starts running, the active pumping mode is the last mode displayed before you pressed the START/STOP key.

Detailed instructions on how to select a pumping mode and adjusting the settings in that mode appear in Chapter 6.

5-9

Image 36
Contents User’s Guide Servicing North America Unpacking Instructions Table of Peristaltic Pump Motor Chapter Specifications Spare Parts and Accessories 10-1 Peristaltic Pump MotorPeristaltic Pump Motor Index RPMIndex III Features IntroductionDescription Introduction Parts of the Pump Motor Front ViewFront View Description FunctionLeft Side View Left Side ViewRight Side View Right Side ViewMembrane Keypad and Display Membrane Keypad DetailMembrane Keypad Details cont’d Flow Rate keyRear View UP and Down Arrow Keys Scrolling LimitsRear View Rear View cont’d Language ButtonParts of the Pump Motor Pump Motor Mounting Configurations Number of Pumps on Getting StartedAttaching the Pump IntroductionAttaching a Single Pump Directly to the Motor Refer to Figures 3-1 throughStacking Two Pumps on One Side of the Motor Placing the Second Pump on Top of the First PumpSelecting Tubing Tubing LifeLoading the Tubing See .2 to set the pumping direction Getting Started Turning on the Power Using the ON/OFF SwitchStopped Display Mode Introduction to the Two Display ModesRunning Display Mode Stopped vs. Running Display ModesStopped Display Mode Operating the Pump MotorDisplaying Pump Messages in Five Different Languages English French Spanish German Italian Régler LA QTÉDefining the Direction of Pumping Selecting the Tubing Inner Diameter Left Pump Right PumpTube Inner Diameters English Metric Priming the Tubing Calibrating the TubingOperating the Pump Motor in the Stopped Display Mode Tips for Optimum Calibration Accuracy Measuring the Temperature of a Fluid Preparing for Pumping in a Specific ModeTotal Volume Running Display Mode RPM ModePumping in the RPM Mode Shows the range of the RPM numbers you can work with RPM Mode Cont’d Flow Rate Mode Pumping in the Flow Rate ModeShows the ranges allowed for the various tubing sizes Flow Rate Ranges cont’d Display Xxx mL/min Flow Rate Mode Flow Rate Mode Time Mode Pumping in the Time ModeTime Range Display Xxxxxx Time Mode Time Mode Total Volume Mode Block Diagram Pumping in the Total Volume ModePumping in the Total Volume Mode Total Volume RangeOperating the Pump Motor in the Running Display Mode Total Volume Mode Cont’d Preventing Tubing from Moving During Pump Operation Other Pumping OptionsAuxiliary Out Remote Monitor 500Ω LED Auxiliary In Remote Start/StopTroubleshooting Guide Display Error MessagesError Message Problem SolutionError Message Running Display Mode and try to select the command againLocked Rotor? Overcurrent Press the Total Volume key Short Circuit? Error Message Other Pumping Problems Stopped Display Mode and refer to SectionProblem Solution Another pump, if necessary Troubleshooting Guide Design Solution MaintenanceTechnical Details Theory of OperationTechnical Details Specifications Calibration AccuracyAverage Flow Rates MotorTubing Materials SpeedAverage Tubing Life ⁄32 300 ⁄16 250 100 ML Per Revolution Specifications Spare Parts and Accessories AccessoriesSpare Parts Part Number DescriptionAccessories cont’d Peristatic Pump 10-4 WARRANTY/DISCLAIMER