Omega Speaker Systems FPU5-MT-220, FPU5-MT-110 manual Another pump, if necessary

Page 69

7Troubleshooting Guide

Problem

 

Solution

 

Motor will not turn

1.

The tubing may be causing a jam. Observe how the tubing is loaded

(OVERCURRENT condition)

 

in the pump(s) and, if necessary, reload it.

 

2.

Detach the pump(s) and check for a mechanical jam. Substitute

To recover from an

 

another pump, if necessary.

3.

Check to see if the fuse is blown. Replace if necessary. Refer to

overcurrent, first turn

the power switch off,

 

Chapter 9 for fuse ratings and chapter 8 for instructions on how to

and then back on.

 

replace it.

Then attempt solutions

 

 

 

 

1 through 8.

4.

Make sure you are using tubing of the appropriate wall thickness for

 

 

the pump(s). Refer to Table 9-1 or 9-2.

 

5.

Make sure you are using tubing of the appropriate durometer for

 

 

your pump(s). Try to operate the motor with tubing of 68 or smaller

 

 

durometer.

 

6.

Make sure the tubing is not caught on the bottom roller. Reposition

 

 

the roller slightly and reload the tubing, if necessary.

 

7.

Make sure no part of the tubing is being constricted by a clamp.

 

 

Loosen clamps if necessary.

 

8.

Turn the unit’s power off and on, adjust the settings, and attempt to

 

 

resume pumping.

 

 

 

 

The pump(s) will not stay on

1.

Make sure you have properly mounted the pump(s) to the motor.

the motor

 

2.

If the pump(s) are not properly mounted, review Section 3.1 on how

 

 

to attach pump(s) to the motor.

 

3.

Remove and properly attach the pump(s) to the motor.

 

 

 

 

Pump messages appear in a language other than the one you want

The LANGUAGE button was inadvertently pressed. Make sure that you are pumping in a mode other than the TIME Mode before pressing the LANGUAGE button, so you can watch the language change. To change languages, refer to Section 5.1.

Problem has not been resolved

Call Customer Service

following the suggestions in

 

this chapter

 

 

 

7-10

Image 69
Contents User’s Guide Servicing North America Unpacking Instructions Table of Peristaltic Pump Motor Peristaltic Pump Motor Chapter Specifications Spare Parts and Accessories 10-1Peristaltic Pump Motor RPM IndexIndex III Features IntroductionDescription Introduction Front View Parts of the Pump MotorFront View Description FunctionLeft Side View Left Side ViewRight Side View Right Side ViewMembrane Keypad Detail Membrane Keypad and DisplayFlow Rate key Membrane Keypad Details cont’dRear View UP and Down Arrow Keys Scrolling LimitsRear View Language Button Rear View cont’dParts of the Pump Motor Getting Started Pump Motor Mounting Configurations Number of Pumps onAttaching the Pump IntroductionRefer to Figures 3-1 through Attaching a Single Pump Directly to the MotorPlacing the Second Pump on Top of the First Pump Stacking Two Pumps on One Side of the MotorSelecting Tubing Tubing LifeLoading the Tubing See .2 to set the pumping direction Getting Started Using the ON/OFF Switch Turning on the PowerStopped Display Mode Introduction to the Two Display ModesStopped vs. Running Display Modes Running Display ModeStopped Display Mode Operating the Pump MotorDisplaying Pump Messages in Five Different Languages Régler LA QTÉ English French Spanish German ItalianDefining the Direction of Pumping Left Pump Right Pump Selecting the Tubing Inner DiameterTube Inner Diameters English Metric Calibrating the Tubing Priming the TubingOperating the Pump Motor in the Stopped Display Mode Tips for Optimum Calibration Accuracy Preparing for Pumping in a Specific Mode Measuring the Temperature of a FluidTotal Volume Running Display Mode RPM ModePumping in the RPM Mode Shows the range of the RPM numbers you can work with RPM Mode Cont’d Pumping in the Flow Rate Mode Flow Rate ModeShows the ranges allowed for the various tubing sizes Flow Rate Ranges cont’d Display Xxx mL/min Flow Rate Mode Flow Rate Mode Pumping in the Time Mode Time ModeTime Range Display Xxxxxx Time Mode Time Mode Block Diagram Pumping in the Total Volume Mode Total Volume ModeTotal Volume Range Pumping in the Total Volume ModeOperating the Pump Motor in the Running Display Mode Total Volume Mode Cont’d Preventing Tubing from Moving During Pump Operation Other Pumping OptionsAuxiliary Out Remote Monitor Auxiliary In Remote Start/Stop 500Ω LEDDisplay Error Messages Troubleshooting GuideError Message Problem SolutionRunning Display Mode and try to select the command again Error MessageLocked Rotor? Overcurrent Press the Total Volume key Short Circuit? Error Message Stopped Display Mode and refer to Section Other Pumping ProblemsProblem Solution Another pump, if necessary Troubleshooting Guide Maintenance Design SolutionTechnical Details Theory of OperationTechnical Details Calibration Accuracy SpecificationsMotor Average Flow RatesTubing Materials SpeedAverage Tubing Life ⁄32 300 ⁄16 250 100 ML Per Revolution Specifications Accessories Spare Parts and AccessoriesSpare Parts Part Number DescriptionAccessories cont’d Peristatic Pump 10-4 WARRANTY/DISCLAIMER