Samsung SHR-3040P Interval Setup, Auto sequence interval for each camera channel, Alarm Setup

Page 33

5.Use the up/down (▲▼) button to move to a desired item.

CHANNEL: Select a channel to set the alarm. You can set the alarm for only one channel.

TYPE: Set the sensor input system.

- <DISABLE> : The sensor does not work.

- <NORMAL OPEN> : The sensor is always open. The alarm will sound when the sensor is closed.

- <NORMAL CLOSE> : The sensor is always closed. The alarm will sound when the sensor is open.

 

ALARM SETUP

CHANNEL

CH1

TYPE

NORMAL OPEN

DURATION

05 SEC

OK

DEFAULT

ALL-DEFAULT

ESC

DURATION: Specify the duration for which the DVR makes the alarm recording when an alarm sounds.

6.When done, select <OK>. Your setting will be applied.

If you select <DEFAULT>, the selected channel will be reset to the default, and if selecting <ALL-DEFAULT>, all the channels will be reset to the factory default.

7.To return to the previous menu, select <ESC>.

Interval Setup

You can specify the interval for Auto Sequence, or PIP (Picture In Picture) mode.

SETUP

See the previous section to repeat steps 1~3. (Page 30)

4.Use the up/down (▲▼) button to select <INTERVAL SETUP>, and press [OK].

5.Use the up/down (▲▼) button to move to a desired item.

CONFIGURATION

HDD MANAGEMENT

CAMERA SETUP

MOTION SETUP

ALARM SETUP

INTERVAL SETUP

DATE/TIME SETUP

PASSWORD SETUP

BUZZER SETUP

 

 

ESC

6. Use the up/down (▲▼) button to move to a desired item.

 

 

INTERVAL SETUP

 

• SEQUENCE SCREEN: In Live full screen, specify the

SEQUENCE SCREEN

01 SEC

auto sequence interval for each camera channel.

PIP SCREEN

01 SEC

EVENT UPDATE

600 SEC

 

• PIP SCREEN: Specify the interval for auto sequence for

 

 

the sub picture in PIP mode.

 

 

• EVENT UPDATE: Specify the interval of updating the

 

 

event list for incoming events.

 

 

If the interval is set to 10 seconds, the next event can be

 

OK

DEFAULT

ESC

updated 10 seconds after the fi rst event was registered

 

 

to the event list.

 

 

7.When done, select <OK>. Your setting will be applied.

If you select <DEFAULT>, the settings will be restored to the factory default.

8.To return to the previous menu, select <ESC>.

English _33

Image 33
Contents Channel DVR 2X Zoom KEY FeaturesImportant Safety Instructions Standards Approvals Overview Before Start BatteryInstallation CD User’s Manual Remote Control/Battery AAAX2What’s Included DVRContents Client Setup What is Web Viewer?Remote Setup Appearance & DimensionFront Panel Rear Panel Audio Remote Control AT a Glance The rack installation is available only in shelf type Checking the Installation EnvironmentInstalling HDD Connecting to a Different Device Connecting to video, audio, and monitorConnecting to RS-485, alarm USB Connection Network ConnectionConnect the power cable of the DVR to the wall outlet LoginLive Getting StartedLive Screen Configuration HDD AutoFull Zoom View the Launcher MenuMode Switch PIP DisplaySplit Screen Single Screen of CH Auto Sequence ZoomFreeze CH4 CH1PTZ RecordPercent Search SearchDate/Time Search Search menu appearsPlay Event SearchEvent Search Specify a time in Main Menu Configuration To set the event updateInterval Setup Event Update Event MonitoringEvent Monitoring on the Spot Monitor Spot SetupUsing the mouse Using the MenuUsing the buttons on the remote control or the front panel  SetupVGA Setup Display SetupDisplay Setup VGA SetupOSD Setup Screen Display SetupOSD Setup Record SetupRecord Setup Quality Select the quality from Highest, High and NormalSETUP, and press OK Schedule SetupSchedule Setup screen appears Schedule SetupConfiguration ConfigurationHDD Management HDD ManagementCamera Setup Camera SetupChannel Select a channel to change the title Alarm Setup Motion Setup By default, all cells are set to disabled Motion SetupSetup Interval SetupAlarm Setup Auto sequence interval for each camera channelDate/Time Setup Password SetupDATE/TIME Setup User ID Select a user ID Buzzer SetupKEY Tone Set the key tone of the button OccursIP Setup TCP/IP SetupTCP/IP Setup External DeviceWhat is DDNS? Ddns SetupIP Setup Ddns SetupCommand Setup PTZ SetupPTZ Setup Command SetupSpeed Setup Speed SetupMouse Setup Mouse SetupSpecify the Sensitivity Spot Setup Audio SetupAdjust the I/O volume Audio SetupBackup BackupYou can backup HDD recording data on a USB storage device Event Popup Duration Specify the event popupSystem Messages File System is not SupportedSize is Larger than Free Space Upgrade Firmware UpgradeYou can upgrade the DVR fi rmware with the latest version Firmware UpgradeFactory Default Factory DefaultChanging Factory Default Select Load Setup Load SetupLanguage You can select a language to your preferenceConnection Network Connection and SettingsStatic IP Mode If you are not using a router for network connectionDynamic IP Dhcp Mode Set Dhcp Mode to Manual in Main MenuUsing DVR Static IP If using a routerDVR Network Router Dhcp IP AddressPort Forwarding of Web Server Port Router Port Forwarding with IP/Port RouterConnecting to the WEB Viewer What is WEB VIEWER?System Requirements  WEB ViewerWEB Viewer AT a Glance Web Viewer Setup Client SetupUpdate To register a web siteRemote Setup BuzzerTo return to the Web Viewer screen, click Close You can set the recording schedule Refer to Schedule SETUP. You can set the recording quality Refer to Record SETUP.Record Configuration Record SchedulePlayer Player at a Glance Edit Tool Image EditWhen done, the ‘C WEBBACKUP’ folder will open Audio signal will not be saved with AVI SaveRemote Viewer Remote Viewer at a Glance You can select Single screen or 4-split modePTZ Control DVR Only the admin user account can access the Setup menu SetupEvent Product Specification USB Appendix Ddns 20C ~ +60C -4F ~ +140F20% to 85% RH 258 247 371 Appearance & DimensionTroubleshooting FAQ Audio Setup Correct disposal of batteries in this product