Samsung AS30UGBNUMG Apply heat to the contraction tube to contract it, Insulation tape to finish

Page 41

HowAA to connect your extended power cables

Items to prepare

(compressor and insulation tape should be prepared by an installation technician.)

Tools

Crimping plier

Connection sleeve (mm)

Insulation tape

Contraction tube (mm)

Spec

MH-14

20xØ7.0(HxOD)

Width 18mm

50xØ8.0(LxOD)

Shape

 

 

 

 

ENGLISH

1.As shown in the figure, peel off the shields from the rubber/wire of the power cable.

- Peel off 20 mm of the wire shields of the tube installed already.

• After peeling off the tube wire, you must insert a contraction tube.

2.Insert both sides of core wire of the power cable into the connection sleeve.

3.Using a compressor, compress the two points and flip it over

and compress another two points in the same location.

-The compression dimension should be 8.0.

-After compressing it, pull both sides of the wire to make sure it is firmly pressed.

4.Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape.

5.Apply heat to the contraction tube to contract it.

(Unit: mm)

Power cable (provided by us)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

20

 

20

60 120

180

Wire tube power cable

20

Connection sleeve

Comp. dim.

Compress it 4 times

5mm

Insulation tape

40mm Contraction tube

6. After tube contraction work is completed, wrap it with the

Insulation tape

insulation tape to finish.

 

• In case of extending the electric wire, please DO NOT use a round-shaped pressing socket. - Incomplete wire connections can cause electric shock or a fire.

41

MAX4 AQ&AST&U_IB&IM_DB98-34063A_E.indd 41

2013-3-18 15:46:41

Image 41
Contents English Contents Important safety symbols and precautions SafetAA y precautionsFollow directions Wall socketFor Using For Cleaning Operation ranges ChecAA king before useChecAA king the name of the parts PowerMain parts  AQ/AS 30/32/36T  Display  AQ/AS 30/32/36TRemote controller buttons ChecAA king the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasicAA function Press the button to set the desired fan speed Press the button to adjust the temperaturePress the Air swing button on the remote controller Using the Turbo functionAdjusA ting the air flow direction Vertical air flowPress the button on the remote controller AA modePress the Time Up or Time Down button to set the time Press the Set button to active it onAdditional options available in On timer mode SettinAA g the On/Off timerPress the On Timer/Off Timer button From the moment you have set the timer Using the Smart Saver functionIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Quiet function UsingAA the Auto Clean functionWhen the air conditioner is turned on 30/32/36T 30/32/36UCleaning the outdoor unit heat exchanger Cleaning the indoor unitOpening the panel Heat exchangerCleaning the air filter CleanAA ing the air conditionerRemoving the Air filter Open the panel and put the Air filter outBio filter sky-blue AACleaning the air conditionerBio filter Deodorizing filter black Deodorizing filterPeriodical checks MainAA taining the air conditionerTroubleshootingAA Connection Flow movement changes. It is normalGeneral information Safety precautionsInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit ChooAA sing the installation locationWhere sulfide gas exists When the air outlet is towards the wall When installing more than 1 outdoor unit Figure Description Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Installation Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Cut off the remaining foam insulation Smooth the cut edgesCutting or extending the pipe AAPurging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareOuter Diameter CuttingAA or extending the pipeTwo hoses are firmly connected, there is no water leakage Drain hose installationHose tight Check for leakage on both side of the drain outletAQseries Purging the connected pipesAdd refrigerant charge according to table below Adding RefrigerantIf you use a pipe shorter than 4 30/32 or 5 36 m Purge time is normalFixing the indoor unit in place PerfoAA rming the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackAppropriate support wall or ground ModelPress the Power button to stop the operation Press the Power button and check the followingFinalAA Check and Trial Operation Check the followingsInsulation tape to finish Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with AS36UGBUMG AS30UGBUMG AATechnical SpecificationsEnglish Egypt Questions or COMMENTS?Air Conditioner