Space Requirements for Outdoor Unit

When installing 1 outdoor unit

Figure Description

 

 

 

Top view

 

Side view

 

 

 

 

 

Air intake

Air outlet

 

 

Air intake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

,

Air flow direction.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Unit : mm)

When the air outlet is opposite the

When the air outlet is towards the

When 3 sides of the outdoor unit are

 

wall

 

 

 

wall

 

 

 

 

blocked by the wall

ENGLISH

300 or more

The upper part of the outdoor unit and the air outlet is towards the wall

2000 or more

or more

 

1500

1500 or more

The upper part of the outdoor unit and the air outlet is opposite the wall

500 or more

300 or more

 

300 or more

150 or more

600 or more

When the walls are blocking front and the rear side of the outdoor unit

1500 or 300 or more more

When installing more than 1 outdoor unit

 

(Unit : mm)

When the air outlet is towards the wall

When 3 sides of the outdoor unit are blocked by the wall

1500 or more

300 or more

300 or more

600 or more 600 or more 600 or more

27

MAX4 AQ&AST&U_IB&IM_DB98-34063A_E.indd 27

2013-3-18 15:46:37

Image 27
Contents English Contents Wall socket SafetAA y precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges ChecAA king before useDisplay  AQ/AS 30/32/36T PowerChecAA king the name of the parts Main parts  AQ/AS 30/32/36T Remote controller buttons ChecAA king the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasicAA function Press the button to set the desired fan speed Press the button to adjust the temperatureVertical air flow Using the Turbo functionPress the Air swing button on the remote controller AdjusA ting the air flow directionPress the Set button to active it on AA modePress the button on the remote controller Press the Time Up or Time Down button to set the timeSettinAA g the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode Turn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is off30/32/36T 30/32/36U UsingAA the Auto Clean functionUsing the Quiet function When the air conditioner is turned onHeat exchanger Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelOpen the panel and put the Air filter out CleanAA ing the air conditionerCleaning the air filter Removing the Air filterAACleaning the air conditioner Bio filterBio filter sky-blue Deodorizing filter black Deodorizing filterPeriodical checks MainAA taining the air conditionerTroubleshootingAA Connection Flow movement changes. It is normalGeneral information Safety precautions a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerChooAA sing the installation location Where sulfide gas existsOutdoor Unit Top view Side view When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberInstallation Cut off the remaining foam insulation Smooth the cut edgesPut a flare nut slightly into the pipe and modify the flare AAPurging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter CuttingAA or extending the pipeCheck for leakage on both side of the drain outlet Drain hose installationTwo hoses are firmly connected, there is no water leakage Hose tightAQseries Purging the connected pipesPurge time is normal Adding RefrigerantAdd refrigerant charge according to table below If you use a pipe shorter than 4 30/32 or 5 36 mFixing the indoor unit in place PerfoAA rming the gas leak testsModel Outdoor unit installed on the wall by rackFixing the outdoor unit in place Appropriate support wall or groundCheck the followings Press the Power button and check the followingPress the Power button to stop the operation FinalAA Check and Trial OperationApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withInsulation tape to finish AS36UGBUMG AS30UGBUMG AATechnical SpecificationsEnglish Egypt Questions or COMMENTS?Air Conditioner