Samsung AS30UGBNUMG ChooAA sing the installation location, Outdoor Unit, Where sulfide gas exists

Page 26

ChooAA sing the installation location

Outdoor Unit

Where it is not exposed to strong wind

Well ventilated and dustless places

Out of the direct sunlight and rain

Where neighbors are not annoyed by operation sound or hot air

Solid wall or support that prevents vibration and is strong enough to hold the product weight

Where there is no risk of flammable gas leakage

When installing the unit at a high place be sure to fix the unit legs

3m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

Install the unit horizontally

Place where drained water does not become any problem.

Place with no plants (especially climbing plants) and where small animal can not access.

• Avoid the following places to prevent malfunction of the unit

- Where there is machine oil

- Salty environment such as seaside areas

- Where sulfide gas exists

- Other special atmosphere areas

Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.

125mm

300mm or more

 

or more

 

Wrap the refrigerant pipes and the drain hose

 

with the absorbent pad and vinyl tape. Refer to

You can select the direction of

page 38 for further details.

draining

 

(left or right).

 

30 m as maximum pipe length

 

and 3 m as minimum pipe length

600mm

(It will reduce noise and vibration)

 

minimum

 

 

30 meters maximum

 

total pipe length

300mm

300mm

minimum

 

minimum

600mm

 

minimum

 

125mm or more

15 meters maximum total pipe length

Make at least one round: It will reduce noise and vibration

The appearance of the unit may be different from the diagram depending on the model.

26

MAX4 AQ&AST&U_IB&IM_DB98-34063A_E.indd 26

2013-3-18 15:46:37

Image 26
Contents English Contents Follow directions SafetAA y precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning ChecAA king before use Operation rangesMain parts  AQ/AS 30/32/36T  PowerChecAA king the name of the parts Display  AQ/AS 30/32/36TChecAA king the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasicAA function Press the button to adjust the temperature Press the button to set the desired fan speedAdjusA ting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowPress the Time Up or Time Down button to set the time AA modePress the button on the remote controller Press the Set button to active it onAdditional options available in On timer mode SettinAA g the On/Off timerPress the On Timer/Off Timer button If the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer Turn off automaticallyWhen the air conditioner is turned on UsingAA the Auto Clean functionUsing the Quiet function 30/32/36T 30/32/36UOpening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerRemoving the Air filter CleanAA ing the air conditionerCleaning the air filter Open the panel and put the Air filter outBio filter sky-blue AACleaning the air conditionerBio filter Deodorizing filter Deodorizing filter blackMainAA taining the air conditioner Periodical checksTroubleshootingAA Flow movement changes. It is normal ConnectionSafety precautions General informationPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyOutdoor Unit ChooAA sing the installation locationWhere sulfide gas exists  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Installation Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe AAPurging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCuttingAA or extending the pipe Outer DiameterHose tight Drain hose installationTwo hoses are firmly connected, there is no water leakage Check for leakage on both side of the drain outletPurging the connected pipes AQseriesIf you use a pipe shorter than 4 30/32 or 5 36 m Adding RefrigerantAdd refrigerant charge according to table below Purge time is normalPerfoAA rming the gas leak tests Fixing the indoor unit in placeAppropriate support wall or ground Outdoor unit installed on the wall by rackFixing the outdoor unit in place ModelFinalAA Check and Trial Operation Press the Power button and check the followingPress the Power button to stop the operation Check the followingsInsulation tape to finish Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with AATechnical Specifications AS36UGBUMG AS30UGBUMGEnglish Questions or COMMENTS? EgyptAir Conditioner