Your new air conditioner not only provides maximum cooling power in the summer, but also can be an efficient heating method in the winter with the advanced“Heat pump”system.“Heat pump”system is 3 times more efficient compare to the other electrical heating appliance, so you can further reduce its running cost. Now, meet year- round needs with one air conditioner.

USING PARTS

 

Safety precautions

3

Checking before use

6

Checking the name of the parts

7

Checking the remote controller

8

Basic function

10

Adjusting the air flow direction

12

Using the Turbo function

12

mode

13

Setting the On/Off timer

14

Using the Smart Saver function

15

Using the Auto Clean function

16

Using the Quiet function

16

Cleaning the air conditioner

17

Maintaining the air conditioner

21

Troubleshooting

22

Look for Everywhere

The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior décor. With its soft color and rounded-edge shape, the new air conditioner adds class to any room. Enjoy what your air conditioner offers both functionally and esthetically.

function

function allows you to set a comfortable sleep temperature while saving energy and having sound sleep.

2

INSTALLATION PARTS

 

Safety precautions

24

Choosing the installation location

25

Accessories

28

Fixing the installation plate

29

Connecting the assembly cable

30

Installing and connecting the assembly

 

pipe of the indoor unit

32

Cutting or extending the pipe

33

Installing and connecting the

 

drain hose of the indoor unit

34

Changing direction of the drain hose

35

Installing and connecting the

 

drain hose of the outdoor unit

36

Purging the connected pipes

36

Performing the gas leak tests

38

Fixing the indoor unit in place

38

Fixing the outdoor unit in place

39

Final check and trial operation

40

Pump down procedure

 

(when removing the product)

40

How to connect your extended power cables

41

Technical Specifications

42

MAX4 AQ&AST&U_IB&IM_DB98-34063A_E.indd 2

2013-3-18 15:46:31

Image 2
Contents English Contents Follow directions SafetAA y precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning ChecAA king before use Operation rangesMain parts  AQ/AS 30/32/36T  PowerChecAA king the name of the parts Display  AQ/AS 30/32/36TChecAA king the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasicAA function Press the button to adjust the temperature Press the button to set the desired fan speedAdjusA ting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowPress the Time Up or Time Down button to set the time AA modePress the button on the remote controller Press the Set button to active it onAdditional options available in On timer mode SettinAA g the On/Off timerPress the On Timer/Off Timer button If the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer Turn off automaticallyWhen the air conditioner is turned on UsingAA the Auto Clean functionUsing the Quiet function 30/32/36T 30/32/36UOpening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerRemoving the Air filter CleanAA ing the air conditionerCleaning the air filter Open the panel and put the Air filter outBio filter sky-blue AACleaning the air conditionerBio filter Deodorizing filter Deodorizing filter blackMainAA taining the air conditioner Periodical checksTroubleshootingAA Flow movement changes. It is normal ConnectionSafety precautions General informationPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyOutdoor Unit ChooAA sing the installation locationWhere sulfide gas exists  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Installation Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe AAPurging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCuttingAA or extending the pipe Outer DiameterHose tight Drain hose installationTwo hoses are firmly connected, there is no water leakage Check for leakage on both side of the drain outletPurging the connected pipes AQseriesIf you use a pipe shorter than 4 30/32 or 5 36 m Adding RefrigerantAdd refrigerant charge according to table below Purge time is normalPerfoAA rming the gas leak tests Fixing the indoor unit in placeAppropriate support wall or ground Outdoor unit installed on the wall by rackFixing the outdoor unit in place ModelFinalAA Check and Trial Operation Press the Power button and check the followingPress the Power button to stop the operation Check the followingsInsulation tape to finish Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with AATechnical Specifications AS36UGBUMG AS30UGBUMGEnglish Questions or COMMENTS? EgyptAir Conditioner