Drain hose installation

1.If necessary, connect the 2-meter extension drain hose to the drain hose.

2.If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.

3.Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.

• If you do not use the other drain hose hole, block it with a rubber stopper.

4. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose,

 

rotate and insert the drain hose into Extended hose for 15~20 mm. Make sure

Drain hose hole

the two hoses are firmly connected, there is no water leakage.

 

5.Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 20mm .

 

 

15~20 mm

20mm

20mm

 

 

or more

or more

 

Drain hose Extension

Drain hose

Extension

 

 

 

drain hose

 

 

 

 

 

drain hose

Vinyl Tape

Foam Insulation

 

 

 

 

6.

Pass the drain hose under the refrigerant pipe, keeping the drain

Shield

 

 

hose tight.

 

 

 

 

 

 

 

 

7.

Pass the drain hose through the hole in the wall. Check if it slants

 

 

 

downwards as seen in the picture.

 

 

Drain hose

Extension drain hose

8.

Using natural drainage method, check the drainage is normal.

 

 

• The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 36 for further details.

Make sure the installed direction of the drain hose is correct.

Inadequate installation may cause condensate water leakage.

• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

ENGLISH

DO NOT WALL UP THE DRAIN HOSE CONNECTION !

Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.

1.Detach the rubber cap with the plier.

2.Detach the drain hose by pulling it and turning to the left.

3.Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan.

4.Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove.

Screw hole

Screw

Drain hose

5. Check for leakage on both side of the drain outlet.

Drain pan outlet

Pour the water in direction of arrow.

Direction of the drained water

Rubber cap

 

 

Make sure the indoor unit is in upright position when you pour water to check for leakage.

Make sure that the water does not overflow onto the electrical part.

35

MAX4 AQ&AST&U_IB&IM_DB98-34063A_E.indd 35

2013-3-18 15:46:39

Image 35
Contents English Contents Wall socket SafetAA y precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges ChecAA king before useDisplay  AQ/AS 30/32/36T PowerChecAA king the name of the parts Main parts  AQ/AS 30/32/36T Remote controller buttons ChecAA king the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasicAA function Press the button to set the desired fan speed Press the button to adjust the temperatureVertical air flow Using the Turbo functionPress the Air swing button on the remote controller AdjusA ting the air flow directionPress the Set button to active it on AA modePress the button on the remote controller Press the Time Up or Time Down button to set the timeAdditional options available in On timer mode SettinAA g the On/Off timerPress the On Timer/Off Timer button Turn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is off30/32/36T 30/32/36U UsingAA the Auto Clean functionUsing the Quiet function When the air conditioner is turned onHeat exchanger Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelOpen the panel and put the Air filter out CleanAA ing the air conditionerCleaning the air filter Removing the Air filterBio filter sky-blue AACleaning the air conditionerBio filter Deodorizing filter black Deodorizing filterPeriodical checks MainAA taining the air conditionerTroubleshootingAA Connection Flow movement changes. It is normalGeneral information Safety precautions a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerOutdoor Unit ChooAA sing the installation locationWhere sulfide gas exists Top view Side view When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the cable Connecting the assembly cableCable specification Installation Extend the assembly cable if necessaryEach wire is labeled with the corresponding terminal number Cut off the remaining foam insulation Smooth the cut edgesPut a flare nut slightly into the pipe and modify the flare AAPurging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter CuttingAA or extending the pipeCheck for leakage on both side of the drain outlet Drain hose installationTwo hoses are firmly connected, there is no water leakage Hose tightAQseries Purging the connected pipesPurge time is normal Adding RefrigerantAdd refrigerant charge according to table below If you use a pipe shorter than 4 30/32 or 5 36 mFixing the indoor unit in place PerfoAA rming the gas leak testsModel Outdoor unit installed on the wall by rackFixing the outdoor unit in place Appropriate support wall or groundCheck the followings Press the Power button and check the followingPress the Power button to stop the operation FinalAA Check and Trial OperationInsulation tape to finish Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with AS36UGBUMG AS30UGBUMG AATechnical SpecificationsEnglish Egypt Questions or COMMENTS?Air Conditioner