In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season.

1. Turn on the air conditioner.

Press the Power button on the remote controller.

2. Set the operation mode.

Press the Mode button on the remote controller

until Cool mode indicator appears on the remote controller display.

The air conditioner operates in Cool mode and it will lower the temperature in your room.

Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry and Fan.

3.Set the temperature.

Press the Temp or - button on the remote controller to increase or decrease the desired temperature.

You can set the desired temperature between the range of 18˚C~30˚C.

You can increase/decrease the temperature by 1˚C.

4. Set the fan speed.

Press the Fan or button on the remote controller to set the desired fan speed.

If room temperature reaches desired value, the air conditioner will shut off cooling for a while and just the fan runs.

Each time you press the Fan or button, fan speed will change in order of Auto, Low, Medium and High.

While you are using the remote controller, make sure correct indicator which matches your selection appears on the remote controller display.

Air flow can be adjusted manually (see pages 20~21 for instructions).

If current outside temperatures are much higher than the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness.

If you operate the air conditioner right after stopping the cooling operation or the temperature reaches to the desired temperature, cool air will not come out around 3 minutes for compressor protection.

operating _15

Image 15
Contents DB98-33838A1 Air ConditionerSerial # Features of your new air conditionerStrong Turbo/Long Function Look for EverywhereDeath Safety informationSafety Information Important safety symbols and precautionsEnsure no water gets into the air conditioner Do not yank the power cable with handsPotential risk of injury or electric shock Do not open the front panel during operation Do not drink drain water coming out of the air conditionerDo not place any objects, especially containers with liquid Insufficient ventilation may result in poor performance Safety information Contents To open the panel Viewing your air conditionerChecking the Indoor Unit and Display Main partsControl Panel Checking the Remote controller Close the cover by place it back to its original position Remote controller displayUsing the remote controller Installing the batteriesTurning the AIR Conditioner on and OFF Selecting Operation ModePress the Power button on the remote controller Operating basic functionCool Dry Fan Set the fan speed FanUsing advanced functions Using the Turbo functionTo deactivate Turbo function To deactivate Long function Using the Long FunctionAdjusting the AIR Flow Direction Vertical air flowAir flow can be directed to your desired position Horizontal air flow Setting Timer To deactivate the On TimerOn Timer Off Timer To deactivate the Off TimerPreset time of On Timer is longer than Off To deactivate the timer combinationCombining On Timer and Off Timer Preset time of On Timer is shorter than OffUsing the AIR Conditioner with the Control Panel Locking the Control Panel When the air conditioner is on or offAir filter Cleaning and maintaining the air conditionerCleaning the Exterior Cleaning the FilterMonths Maintaining Your AIR ConditionerPeriodical checks Type Description Every Once aAir conditioner does not start operating immediately Storing the remote controllerInternal protections via the unit control system Type DescriptionAppendix TroubleshootingOn the floor Operation RangesCondensation may occur on the indoor unit 21˚C to 54˚CSafety Precautions Power supply line, fuse or circuit breaker Part Name Accessory Parts ListTop view Selection of Installation PlaceCircuit Breaker PowerElectric wire Below 20m 5mm Below 50m 4mm Allowable voltage Electrical WorkIndoor unit Outdoor UnitScrew Tightening torque kgf cm Outdoor Unit Installation MethodInstallation Procedures Anchor bolt fixing dimensionsIndoor unit Outdoor Unit Indoor unitCut the pipe using the pipe cutter Connection of Refrigerant PipingOuter DiameterD Amm  Drill a hole of 60mm in diameter to the outside Drilling a Hole in the WallDrain Hose Fixing the Indoor UnitInsulation Foamed Polyethylene Pump Air Purge※ Be sure that all valve cocks are closed VacuumStop operation Outside temperature 35CRefrigerant Charging Refill the refrigerant slowly checking the pressureCheck and Test Operation CheckIs grounding properly made? Test Operation Pump Down Procedure When removing the productIndoor unit Packing and Unpacking GuideCushion-top  Packing case  Outdoor unit  Insulation tape Howto connectyour extended power cables444 77 Samsung Questions or COMMENTS?021-8255 183-2255