Samsung AP30M0AXUMG, AP30M0ANXSG, AP30M0ANUMG manual Setting Timer, To deactivate the On Timer

Page 22

using advanced functions

SETTING TIMER

This advanced Timer function allows you to turn on/off your air conditioner automatically even when you are away. Simply set the time and your air conditioner will

turn on/off automatically.

On Timer

This function allows you to turn on the air conditioner automatically within the time range of 24 hours.

On timer is available while your air conditioner is off.

1. Press the On Timer button on the remote controller.

On timer indicator blinks on the remote controller display.

2. Set the time you want the air conditioner to turn on automatically.

Press the Time Up or Time Down button on the remote controller to change the time setting while On timer indicator is blinking.

You can set the time up to 24 hours, increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours.

3. Press the Set button on the remote controller to active it on.

The remote controller display will show the hour(s) you have set for 3 seconds and set desired temperature will display.

The air conditioner will operate automatically at set time and then On timer indicator stops blinking and stays on. If On timer is not set within 10 seconds, the air conditioner will end setting.

4. Set the operation mode.

Press the Mode button on the remote controller until the desired mode appears on the remote controller display.

The air conditioner will operate in the mode you set.

On timer function is available in Auto/Cool/Dry and Fan mode.

Temperature can also be adjusted (see step 3 on page 14 for instructions).

All the indicators other than On Timer indicator will disappear approximately after 10 seconds after the setup.

When the On Timer setting is done, you can press the On Timer button again to change the preset time. Press the Time Up or Time Down button to change time setting and then press the Set button to active it on.

To deactivate the On Timer

1.Press the Cancel button on the remote controller while On Timer is on. On timer you set will be canceled and On timer indicator will disappear.

22_ using advanced functions

Image 22
Contents Air Conditioner DB98-33838A1Look for Everywhere Features of your new air conditionerStrong Turbo/Long Function Serial #Important safety symbols and precautions Safety informationSafety Information DeathDo not yank the power cable with hands Ensure no water gets into the air conditionerPotential risk of injury or electric shock Do not drink drain water coming out of the air conditioner Do not open the front panel during operationDo not place any objects, especially containers with liquid Insufficient ventilation may result in poor performance Safety information Contents Main parts Viewing your air conditionerChecking the Indoor Unit and Display To open the panelControl Panel Checking the Remote controller Installing the batteries Remote controller displayUsing the remote controller Close the cover by place it back to its original positionOperating basic function Selecting Operation ModePress the Power button on the remote controller Turning the AIR Conditioner on and OFFCool Dry Fan Fan Set the fan speedUsing the Turbo function Using advanced functionsTo deactivate Turbo function Using the Long Function To deactivate Long functionVertical air flow Adjusting the AIR Flow DirectionAir flow can be directed to your desired position Horizontal air flow To deactivate the On Timer Setting TimerOn Timer To deactivate the Off Timer Off TimerPreset time of On Timer is shorter than Off To deactivate the timer combinationCombining On Timer and Off Timer Preset time of On Timer is longer than OffUsing the AIR Conditioner with the Control Panel When the air conditioner is on or off Locking the Control PanelCleaning the Filter Cleaning and maintaining the air conditionerCleaning the Exterior Air filterType Description Every Once a Maintaining Your AIR ConditionerPeriodical checks MonthsType Description Storing the remote controllerInternal protections via the unit control system Air conditioner does not start operating immediatelyTroubleshooting Appendix21˚C to 54˚C Operation RangesCondensation may occur on the indoor unit On the floorSafety Precautions Power supply line, fuse or circuit breaker Accessory Parts List Part NameSelection of Installation Place Top viewElectrical Work PowerElectric wire Below 20m 5mm Below 50m 4mm Allowable voltage Circuit BreakerOutdoor Unit Indoor unitScrew Tightening torque kgf cm Anchor bolt fixing dimensions Installation MethodInstallation Procedures Outdoor UnitIndoor unit Indoor unit Outdoor UnitConnection of Refrigerant Piping Cut the pipe using the pipe cutterOuter DiameterD Amm Drilling a Hole in the Wall  Drill a hole of 60mm in diameter to the outsideFixing the Indoor Unit Drain HoseInsulation Foamed Polyethylene Vacuum Air Purge※ Be sure that all valve cocks are closed PumpRefill the refrigerant slowly checking the pressure Outside temperature 35CRefrigerant Charging Stop operationCheck Check and Test OperationIs grounding properly made? Pump Down Procedure When removing the product Test OperationPacking and Unpacking Guide Indoor unitCushion-top  Packing case  Outdoor unit  Howto connectyour extended power cables Insulation tape183-2255 Questions or COMMENTS?021-8255 444 77 Samsung