Off Timer

This function allows you to turn off the air conditioner automatically within the time range of 24 hours. Off timer is available while your air conditioner is on.

1. Press the Off Timer button on the remote controller.

Off timer indicator blinks on the remote controller display.

2.Set the time you want the air conditioner to turn off

automatically.

Press the Time Up or Time Down button on the remote controller to change the time setting while Off timer indicator is blinking.

You can set the time up to 24 hours, increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours.

3. Press the Set button on the remote controller to

active it on.

The remote controller display will show the hour(s)

you have set for 3 seconds and set desired temperature will display.

The air conditioner will operate automatically at set time and then Off timer indicator stops blinking and stays on. If Off timer is not set within 10 seconds, the air conditioner will end setting.

When the Off Timer setting is done, you can press the Off Timer button again to change the preset time.

Press the Time Up or Time Down button to change the time setting and then press the Set button to active it on.

You can combine Off timer function with On timer function to turn on and then off the air conditioner at the desired time (see page 24 for instructions).

To deactivate the Off Timer

1.Press the Cancel button on the remote controller while Off Timer is on. Off timer you set will be canceled and Off timer indicator will disappear.

using advanced functions _23

Image 23
Contents DB98-33838A1 Air ConditionerSerial # Features of your new air conditionerStrong Turbo/Long Function Look for EverywhereDeath Safety informationSafety Information Important safety symbols and precautionsEnsure no water gets into the air conditioner Do not yank the power cable with handsPotential risk of injury or electric shock Do not place any objects, especially containers with liquid Do not open the front panel during operationDo not drink drain water coming out of the air conditioner Insufficient ventilation may result in poor performance Safety information Contents To open the panel Viewing your air conditionerChecking the Indoor Unit and Display Main partsControl Panel Checking the Remote controller Close the cover by place it back to its original position Remote controller displayUsing the remote controller Installing the batteriesTurning the AIR Conditioner on and OFF Selecting Operation ModePress the Power button on the remote controller Operating basic functionCool Dry Fan Set the fan speed FanTo deactivate Turbo function Using advanced functionsUsing the Turbo function To deactivate Long function Using the Long FunctionAir flow can be directed to your desired position Adjusting the AIR Flow DirectionVertical air flow Horizontal air flow On Timer Setting TimerTo deactivate the On Timer Off Timer To deactivate the Off TimerPreset time of On Timer is longer than Off To deactivate the timer combinationCombining On Timer and Off Timer Preset time of On Timer is shorter than OffUsing the AIR Conditioner with the Control Panel Locking the Control Panel When the air conditioner is on or offAir filter Cleaning and maintaining the air conditionerCleaning the Exterior Cleaning the FilterMonths Maintaining Your AIR ConditionerPeriodical checks Type Description Every Once aAir conditioner does not start operating immediately Storing the remote controllerInternal protections via the unit control system Type DescriptionAppendix TroubleshootingOn the floor Operation RangesCondensation may occur on the indoor unit 21˚C to 54˚CSafety Precautions Power supply line, fuse or circuit breaker Part Name Accessory Parts ListTop view Selection of Installation PlaceCircuit Breaker PowerElectric wire Below 20m 5mm Below 50m 4mm Allowable voltage Electrical WorkScrew Tightening torque kgf cm Indoor unitOutdoor Unit Outdoor Unit Installation MethodInstallation Procedures Anchor bolt fixing dimensionsIndoor unit Outdoor Unit Indoor unitOuter DiameterD Amm Cut the pipe using the pipe cutterConnection of Refrigerant Piping  Drill a hole of 60mm in diameter to the outside Drilling a Hole in the WallInsulation Foamed Polyethylene Drain HoseFixing the Indoor Unit Pump Air Purge※ Be sure that all valve cocks are closed VacuumStop operation Outside temperature 35CRefrigerant Charging Refill the refrigerant slowly checking the pressureIs grounding properly made? Check and Test OperationCheck Test Operation Pump Down Procedure When removing the productIndoor unit Packing and Unpacking GuideCushion-top  Packing case  Outdoor unit  Insulation tape Howto connectyour extended power cables444 77 Samsung Questions or COMMENTS?021-8255 183-2255