Samsung AP30M0ANXSG, AP30M0ANUMG manual Maintaining Your AIR Conditioner, Periodical checks, Months

Page 28

cleaning and maintaining the air conditioner

MAINTAINING YOUR AIR CONDITIONER

If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.

1.Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and turn off the circuit breaker. There may be internal damage if moisture is left in components.

2.Before using the air conditioner again, dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours. This helps remove odors which may have generated from dampness.

Periodical checks

Refer to the following chart to maintain the air conditioner properly.

Type

Description

Every 2

Every 3

Every 4

Once a

weeks

months

months

year

 

 

 

Clean the air filter (1)

 

 

 

 

 

 

 

 

 

Indoor

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

Thoroughly clean the heat exchanger (2)

 

 

 

unit

 

 

 

 

Clean the condensate drain pipe (2)

 

 

 

 

 

 

 

 

 

 

Replace the remote controller batteries (1)

 

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the outside of

 

 

 

 

the unit (2)

 

 

 

 

 

 

 

 

 

Clean the heat exchanger on the inside of the

 

 

 

 

unit (2)

 

 

 

 

 

 

 

 

 

Clean the electric components with jets of air

 

 

 

 

(2)

 

 

 

Outdoor

 

 

 

 

Verify that all the electric components are

 

 

 

 

unit

 

 

 

firmly tightened (2)

 

 

 

 

 

 

 

 

 

Clean the fan (2)

 

 

 

 

 

 

 

 

 

 

Verify that all the fan assembly is firmly

 

 

 

 

tightened (2)

 

 

 

 

 

 

 

 

 

Clean the condensate drain pan (2)

 

 

 

 

 

 

 

 

 

: This check mark requires checking the indoor/outdoor unit periodically, following to the description to maintain the air conditioner properly.

The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner. The frequency of these operations varies according to the characteristics of the area, the amount of dust, etc.

(1)The described operations should be performed more frequently if the area of installation is very dusty.

(2)These operations must always be performed by qualified personnel. For more detailed information, see the Installation part.

28_ cleaning and maintaining

Image 28
Contents Air Conditioner DB98-33838A1Features of your new air conditioner Strong Turbo/Long FunctionLook for Everywhere Serial #Safety information Safety InformationImportant safety symbols and precautions DeathDo not yank the power cable with hands Ensure no water gets into the air conditionerPotential risk of injury or electric shock Do not drink drain water coming out of the air conditioner Do not open the front panel during operationDo not place any objects, especially containers with liquid Insufficient ventilation may result in poor performance Safety information Contents Viewing your air conditioner Checking the Indoor Unit and DisplayMain parts To open the panelControl Panel Checking the Remote controller Remote controller display Using the remote controllerInstalling the batteries Close the cover by place it back to its original positionSelecting Operation Mode Press the Power button on the remote controllerOperating basic function Turning the AIR Conditioner on and OFFCool Dry Fan Fan Set the fan speedUsing the Turbo function Using advanced functionsTo deactivate Turbo function Using the Long Function To deactivate Long functionVertical air flow Adjusting the AIR Flow DirectionAir flow can be directed to your desired position Horizontal air flow To deactivate the On Timer Setting TimerOn Timer To deactivate the Off Timer Off TimerTo deactivate the timer combination Combining On Timer and Off TimerPreset time of On Timer is shorter than Off Preset time of On Timer is longer than OffUsing the AIR Conditioner with the Control Panel When the air conditioner is on or off Locking the Control PanelCleaning and maintaining the air conditioner Cleaning the ExteriorCleaning the Filter Air filterMaintaining Your AIR Conditioner Periodical checksType Description Every Once a MonthsStoring the remote controller Internal protections via the unit control systemType Description Air conditioner does not start operating immediatelyTroubleshooting AppendixOperation Ranges Condensation may occur on the indoor unit21˚C to 54˚C On the floorSafety Precautions Power supply line, fuse or circuit breaker Accessory Parts List Part NameSelection of Installation Place Top viewPower Electric wire Below 20m 5mm Below 50m 4mm Allowable voltageElectrical Work Circuit BreakerOutdoor Unit Indoor unitScrew Tightening torque kgf cm Installation Method Installation ProceduresAnchor bolt fixing dimensions Outdoor UnitIndoor unit Indoor unit Outdoor UnitConnection of Refrigerant Piping Cut the pipe using the pipe cutterOuter DiameterD Amm Drilling a Hole in the Wall  Drill a hole of 60mm in diameter to the outsideFixing the Indoor Unit Drain HoseInsulation Foamed Polyethylene Air Purge ※ Be sure that all valve cocks are closedVacuum PumpOutside temperature 35C Refrigerant ChargingRefill the refrigerant slowly checking the pressure Stop operationCheck Check and Test OperationIs grounding properly made? Pump Down Procedure When removing the product Test OperationPacking and Unpacking Guide Indoor unitCushion-top  Packing case  Outdoor unit  Howto connectyour extended power cables Insulation tapeQuestions or COMMENTS? 021-8255183-2255 444 77 Samsung