Samsung AP30M0ANXSG, AP30M0ANUMG, AP30M0AXUMG Adjusting the AIR Flow Direction, Vertical air flow

Page 20

using advanced functions

ADJUSTING THE AIR FLOW DIRECTION

Air flow can be directed to your desired position.

Vertical air flow

1.Press the Air swing(Up/Down) button on the remote controller. The air flow blades move up and down.

To keep the air flow direction in a constant position, press the Air swing(Up/Down) button on the remote controller again.

20_ using advanced functions

Image 20
Contents Air Conditioner DB98-33838A1Features of your new air conditioner Strong Turbo/Long FunctionLook for Everywhere Serial #Safety information Safety InformationImportant safety symbols and precautions DeathDo not yank the power cable with hands Ensure no water gets into the air conditionerPotential risk of injury or electric shock Do not place any objects, especially containers with liquid Do not open the front panel during operationDo not drink drain water coming out of the air conditioner Insufficient ventilation may result in poor performance Safety information Contents Viewing your air conditioner Checking the Indoor Unit and DisplayMain parts To open the panelControl Panel Checking the Remote controller Remote controller display Using the remote controllerInstalling the batteries Close the cover by place it back to its original positionSelecting Operation Mode Press the Power button on the remote controllerOperating basic function Turning the AIR Conditioner on and OFFCool Dry Fan Fan Set the fan speedTo deactivate Turbo function Using advanced functionsUsing the Turbo function Using the Long Function To deactivate Long functionAir flow can be directed to your desired position Adjusting the AIR Flow DirectionVertical air flow Horizontal air flow On Timer Setting TimerTo deactivate the On Timer To deactivate the Off Timer Off TimerTo deactivate the timer combination Combining On Timer and Off TimerPreset time of On Timer is shorter than Off Preset time of On Timer is longer than OffUsing the AIR Conditioner with the Control Panel When the air conditioner is on or off Locking the Control PanelCleaning and maintaining the air conditioner Cleaning the ExteriorCleaning the Filter Air filterMaintaining Your AIR Conditioner Periodical checksType Description Every Once a MonthsStoring the remote controller Internal protections via the unit control systemType Description Air conditioner does not start operating immediatelyTroubleshooting AppendixOperation Ranges Condensation may occur on the indoor unit21˚C to 54˚C On the floorSafety Precautions Power supply line, fuse or circuit breaker Accessory Parts List Part NameSelection of Installation Place Top viewPower Electric wire Below 20m 5mm Below 50m 4mm Allowable voltageElectrical Work Circuit BreakerScrew Tightening torque kgf cm Indoor unitOutdoor Unit Installation Method Installation ProceduresAnchor bolt fixing dimensions Outdoor UnitIndoor unit Indoor unit Outdoor UnitOuter DiameterD Amm Cut the pipe using the pipe cutterConnection of Refrigerant Piping Drilling a Hole in the Wall  Drill a hole of 60mm in diameter to the outsideInsulation Foamed Polyethylene Drain HoseFixing the Indoor Unit Air Purge ※ Be sure that all valve cocks are closedVacuum PumpOutside temperature 35C Refrigerant ChargingRefill the refrigerant slowly checking the pressure Stop operationIs grounding properly made? Check and Test OperationCheck Pump Down Procedure When removing the product Test OperationPacking and Unpacking Guide Indoor unitCushion-top  Packing case  Outdoor unit  Howto connectyour extended power cables Insulation tapeQuestions or COMMENTS? 021-8255183-2255 444 77 Samsung
Related manuals
Manual 50 pages 17.59 Kb