SAFETY PRECAUTIONS

Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

WARNING

• Always disconnect the air conditioner from the power supply before servicing it or

accessing its internal components.

 

• Verify that installation and testing operations are performed by qualified personnel.

 

• Verify that the air conditioner is not installed in an easily accessible area.

 

 

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and hydraulic lines. Failure to comply with these instructions or to comply with the requirements set forth in the “Operating limits” table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly.

These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

Installing the unit

IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.)

32_ installation part

Image 32
Contents Air Conditioner DB98-33838A1Features of your new air conditioner Strong Turbo/Long FunctionLook for Everywhere Serial #Safety information Safety InformationImportant safety symbols and precautions DeathDo not yank the power cable with hands Ensure no water gets into the air conditionerPotential risk of injury or electric shock Do not place any objects, especially containers with liquid Do not open the front panel during operationDo not drink drain water coming out of the air conditioner Insufficient ventilation may result in poor performance Safety information Contents Viewing your air conditioner Checking the Indoor Unit and DisplayMain parts To open the panelControl Panel Checking the Remote controller Remote controller display Using the remote controllerInstalling the batteries Close the cover by place it back to its original positionSelecting Operation Mode Press the Power button on the remote controllerOperating basic function Turning the AIR Conditioner on and OFFCool Dry Fan Fan Set the fan speedTo deactivate Turbo function Using advanced functionsUsing the Turbo function Using the Long Function To deactivate Long functionAir flow can be directed to your desired position Adjusting the AIR Flow DirectionVertical air flow Horizontal air flow On Timer Setting TimerTo deactivate the On Timer To deactivate the Off Timer Off TimerTo deactivate the timer combination Combining On Timer and Off TimerPreset time of On Timer is shorter than Off Preset time of On Timer is longer than OffUsing the AIR Conditioner with the Control Panel When the air conditioner is on or off Locking the Control PanelCleaning and maintaining the air conditioner Cleaning the ExteriorCleaning the Filter Air filterMaintaining Your AIR Conditioner Periodical checksType Description Every Once a MonthsStoring the remote controller Internal protections via the unit control systemType Description Air conditioner does not start operating immediatelyTroubleshooting AppendixOperation Ranges Condensation may occur on the indoor unit21˚C to 54˚C On the floorSafety Precautions Power supply line, fuse or circuit breaker Accessory Parts List Part NameSelection of Installation Place Top viewPower Electric wire Below 20m 5mm Below 50m 4mm Allowable voltageElectrical Work Circuit BreakerScrew Tightening torque kgf cm Indoor unitOutdoor Unit Installation Method Installation ProceduresAnchor bolt fixing dimensions Outdoor UnitIndoor unit Indoor unit Outdoor UnitOuter DiameterD Amm Cut the pipe using the pipe cutterConnection of Refrigerant Piping Drilling a Hole in the Wall  Drill a hole of 60mm in diameter to the outsideInsulation Foamed Polyethylene Drain HoseFixing the Indoor Unit Air Purge ※ Be sure that all valve cocks are closedVacuum PumpOutside temperature 35C Refrigerant ChargingRefill the refrigerant slowly checking the pressure Stop operationIs grounding properly made? Check and Test OperationCheck Pump Down Procedure When removing the product Test OperationPacking and Unpacking Guide Indoor unitCushion-top  Packing case  Outdoor unit  Howto connectyour extended power cables Insulation tapeQuestions or COMMENTS? 021-8255183-2255 444 77 Samsung