Samsung AP30M0AXUMG, AP30M0ANXSG manual Installation Method, Outdoor Unit, Installation Procedures

Page 38

Installation Method

Outdoor Unit

When using the anchor bolt

1.Fix the unit on a flat, rigid floor using the anchor bolt. (Anchor bolt : M10 x 4 points - separately purchased)

Anchor bolt fixing dimensions

660mm

340mm

When using the rubber leg

1. Put the rubber leg to the outdoor unit leg.

Outdoor unit

leg Rubber leg

Installation Procedures

1.The piping of this unit can be connected to the right, left, and rear side.

When you hit the area for piping connection slightly with a hammer, a hole is made.

Holes for piping connection (4 points)

Protective piping cover

Piping

Drain hose

Protective piping cover

Drain

hose

Piping

When the hole on the wall is lower than the hole for piping connection.

When the hole on the wall is higher than the hole for piping connection.

2.Open the front panel and separate it from the unit.

-Be careful of the power lines connected to control panel when removing.

3.Bend the connection pipe to an appropriate length using the spring bender depending upon the installation place.

-Allowable pipe length : Maximum 15m

-Allowable pipe drop distance : Maximum 10m

-Make no more than ten bending points on the pipe

When the pipe length is in excess of the standard pipe length of 5m, add the refrigerant (R22) of 30g for each additional 1m.

If the pipe is lengthened, the performance of the unit is degraded, and the service life is shortened. Therefore, the pipe length should be as short as possible (less than 15m).

38_ installation part

Image 38
Contents Air Conditioner DB98-33838A1Look for Everywhere Features of your new air conditionerStrong Turbo/Long Function Serial #Important safety symbols and precautions Safety informationSafety Information DeathDo not yank the power cable with hands Ensure no water gets into the air conditionerPotential risk of injury or electric shock Do not place any objects, especially containers with liquid Do not open the front panel during operationDo not drink drain water coming out of the air conditioner Insufficient ventilation may result in poor performance Safety information Contents Main parts Viewing your air conditionerChecking the Indoor Unit and Display To open the panelControl Panel Checking the Remote controller Installing the batteries Remote controller displayUsing the remote controller Close the cover by place it back to its original positionOperating basic function Selecting Operation ModePress the Power button on the remote controller Turning the AIR Conditioner on and OFFCool Dry Fan Fan Set the fan speedTo deactivate Turbo function Using advanced functionsUsing the Turbo function Using the Long Function To deactivate Long functionAir flow can be directed to your desired position Adjusting the AIR Flow DirectionVertical air flow Horizontal air flow On Timer Setting TimerTo deactivate the On Timer To deactivate the Off Timer Off TimerPreset time of On Timer is shorter than Off To deactivate the timer combinationCombining On Timer and Off Timer Preset time of On Timer is longer than OffUsing the AIR Conditioner with the Control Panel When the air conditioner is on or off Locking the Control PanelCleaning the Filter Cleaning and maintaining the air conditionerCleaning the Exterior Air filterType Description Every Once a Maintaining Your AIR ConditionerPeriodical checks MonthsType Description Storing the remote controllerInternal protections via the unit control system Air conditioner does not start operating immediatelyTroubleshooting Appendix21˚C to 54˚C Operation RangesCondensation may occur on the indoor unit On the floorSafety Precautions Power supply line, fuse or circuit breaker Accessory Parts List Part NameSelection of Installation Place Top viewElectrical Work PowerElectric wire Below 20m 5mm Below 50m 4mm Allowable voltage Circuit BreakerScrew Tightening torque kgf cm Indoor unitOutdoor Unit Anchor bolt fixing dimensions Installation MethodInstallation Procedures Outdoor UnitIndoor unit Indoor unit Outdoor UnitOuter DiameterD Amm Cut the pipe using the pipe cutterConnection of Refrigerant Piping Drilling a Hole in the Wall  Drill a hole of 60mm in diameter to the outsideInsulation Foamed Polyethylene Drain HoseFixing the Indoor Unit Vacuum Air Purge※ Be sure that all valve cocks are closed PumpRefill the refrigerant slowly checking the pressure Outside temperature 35CRefrigerant Charging Stop operationIs grounding properly made? Check and Test OperationCheck Pump Down Procedure When removing the product Test OperationPacking and Unpacking Guide Indoor unitCushion-top  Packing case  Outdoor unit  Howto connectyour extended power cables Insulation tape183-2255 Questions or COMMENTS?021-8255 444 77 Samsung