Samsung AP30M0AXXSG, AP30M0ANXSG manual Insufficient ventilation may result in poor performance

Page 7

Do not touch the pipe connected to the air conditioner.

Install the indoor unit away from lighting apparatus using the ballast.

If you use the wireless remote controller, reception error may occur due to the ballast of the lighting apparatus.

Install the outdoor unit where operating noise and vibration will not disturb your neighbor and in a well-ventilated area with no obstacle.

Potential risk of malfunction.

Operating noise may disturb your neighbor.

Make sure that there are no obstacles or covers that block the air conditioner. Allow sufficient space for air circulation.

Insufficient ventilation may result in poor performance.

If the power cable is damaged, the manufacturer or a qualified service technician must replace it.

If a power outage occurs while the air conditioner is working, turn off the power source immediately.

Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.

Check for damage on delivery. If damaged, do not install the air conditioner and call the place of purchase immediately.

Keep indoor temperatures stable and not extremely cold, especially where there are children, elderly or disabled people.

The packaging material and used batteries of the remote controller (optional) must be disposed of in accordance with the national standards.

The refrigerant used in the air conditioner must be treated as chemical waste. Dispose the refrigerant following national standards.

Have a qualified service technician install the air conditioner and perform a trial operation.

Firmly connect the drain hose to the air conditioner for proper water drainage. Check for damages on the outdoor unit installation pad at least once a year.

Potential risk of personal injury or property loss.

When using a wireless remote controller, the distance should not be more than 7 meters from the air conditioner.

If the remote controller is not used for a long period of time, remove the batteries to prevent leakage of electrolyte.

When cleaning the outdoor unit, touch the heat exchanger radiator fins with extreme care.

Wearing thick gloves can protect your hands.

Make sure that the condensed water dripping from the drain hose runs out properly and safely.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety: Young children should be supervised to ensure that they do not play with the appliance.

safety information _07

Image 7
Contents DB98-33838A1 Air ConditionerSerial # Features of your new air conditionerStrong Turbo/Long Function Look for EverywhereDeath Safety informationSafety Information Important safety symbols and precautionsEnsure no water gets into the air conditioner Do not yank the power cable with handsPotential risk of injury or electric shock Do not drink drain water coming out of the air conditioner Do not open the front panel during operationDo not place any objects, especially containers with liquid Insufficient ventilation may result in poor performance Safety information Contents To open the panel Viewing your air conditionerChecking the Indoor Unit and Display Main partsControl Panel Checking the Remote controller Close the cover by place it back to its original position Remote controller displayUsing the remote controller Installing the batteriesTurning the AIR Conditioner on and OFF Selecting Operation ModePress the Power button on the remote controller Operating basic functionCool Dry Fan Set the fan speed FanUsing the Turbo function Using advanced functionsTo deactivate Turbo function To deactivate Long function Using the Long FunctionVertical air flow Adjusting the AIR Flow DirectionAir flow can be directed to your desired position Horizontal air flow To deactivate the On Timer Setting TimerOn Timer Off Timer To deactivate the Off TimerPreset time of On Timer is longer than Off To deactivate the timer combinationCombining On Timer and Off Timer Preset time of On Timer is shorter than OffUsing the AIR Conditioner with the Control Panel Locking the Control Panel When the air conditioner is on or offAir filter Cleaning and maintaining the air conditionerCleaning the Exterior Cleaning the FilterMonths Maintaining Your AIR ConditionerPeriodical checks Type Description Every Once aAir conditioner does not start operating immediately Storing the remote controllerInternal protections via the unit control system Type DescriptionAppendix TroubleshootingOn the floor Operation RangesCondensation may occur on the indoor unit 21˚C to 54˚CSafety Precautions Power supply line, fuse or circuit breaker Part Name Accessory Parts ListTop view Selection of Installation PlaceCircuit Breaker PowerElectric wire Below 20m 5mm Below 50m 4mm Allowable voltage Electrical WorkOutdoor Unit Indoor unitScrew Tightening torque kgf cm Outdoor Unit Installation MethodInstallation Procedures Anchor bolt fixing dimensionsIndoor unit Outdoor Unit Indoor unitConnection of Refrigerant Piping Cut the pipe using the pipe cutterOuter DiameterD Amm  Drill a hole of 60mm in diameter to the outside Drilling a Hole in the WallFixing the Indoor Unit Drain HoseInsulation Foamed Polyethylene Pump Air Purge※ Be sure that all valve cocks are closed VacuumStop operation Outside temperature 35CRefrigerant Charging Refill the refrigerant slowly checking the pressureCheck Check and Test OperationIs grounding properly made? Test Operation Pump Down Procedure When removing the productIndoor unit Packing and Unpacking GuideCushion-top  Packing case  Outdoor unit  Insulation tape Howto connectyour extended power cables444 77 Samsung Questions or COMMENTS?021-8255 183-2255