Samsung AP30M0ANUMG, AP30M0ANXSG manual Check and Test Operation, Is grounding properly made?

Page 45

Check and Test Operation

Check

Be sure to check the following again after completion of installation.

1.Check the piping connection area for any gas leakage.

Indoor connection area

Outdoor connection area

2. Is the drain hose properly connected?

3. Is the insulation of the piping in good condition?

Pipe insulator (Over 7mm foamed

polyethylene or EPDM foam)

Pipie connection part insulator (Over

5mm foamed polyethylene)

4. Is grounding properly made?

More than 30cm

installation part _45

Image 45
Contents DB98-33838A1 Air ConditionerStrong Turbo/Long Function Features of your new air conditionerLook for Everywhere Serial #Safety Information Safety informationImportant safety symbols and precautions DeathEnsure no water gets into the air conditioner Do not yank the power cable with handsPotential risk of injury or electric shock Do not open the front panel during operation Do not drink drain water coming out of the air conditionerDo not place any objects, especially containers with liquid Insufficient ventilation may result in poor performance Safety information Contents Checking the Indoor Unit and Display Viewing your air conditionerMain parts To open the panelControl Panel Checking the Remote controller Using the remote controller Remote controller displayInstalling the batteries Close the cover by place it back to its original positionPress the Power button on the remote controller Selecting Operation ModeOperating basic function Turning the AIR Conditioner on and OFFCool Dry Fan Set the fan speed FanUsing advanced functions Using the Turbo functionTo deactivate Turbo function To deactivate Long function Using the Long FunctionAdjusting the AIR Flow Direction Vertical air flowAir flow can be directed to your desired position Horizontal air flow Setting Timer To deactivate the On TimerOn Timer Off Timer To deactivate the Off TimerCombining On Timer and Off Timer To deactivate the timer combinationPreset time of On Timer is shorter than Off Preset time of On Timer is longer than OffUsing the AIR Conditioner with the Control Panel Locking the Control Panel When the air conditioner is on or offCleaning the Exterior Cleaning and maintaining the air conditionerCleaning the Filter Air filterPeriodical checks Maintaining Your AIR ConditionerType Description Every Once a MonthsInternal protections via the unit control system Storing the remote controllerType Description Air conditioner does not start operating immediatelyAppendix TroubleshootingCondensation may occur on the indoor unit Operation Ranges21˚C to 54˚C On the floorSafety Precautions Power supply line, fuse or circuit breaker Part Name Accessory Parts ListTop view Selection of Installation PlaceElectric wire Below 20m 5mm Below 50m 4mm Allowable voltage PowerElectrical Work Circuit BreakerIndoor unit Outdoor UnitScrew Tightening torque kgf cm Installation Procedures Installation MethodAnchor bolt fixing dimensions Outdoor UnitIndoor unit Outdoor Unit Indoor unitCut the pipe using the pipe cutter Connection of Refrigerant PipingOuter DiameterD Amm  Drill a hole of 60mm in diameter to the outside Drilling a Hole in the WallDrain Hose Fixing the Indoor UnitInsulation Foamed Polyethylene ※ Be sure that all valve cocks are closed Air PurgeVacuum PumpRefrigerant Charging Outside temperature 35CRefill the refrigerant slowly checking the pressure Stop operationCheck and Test Operation CheckIs grounding properly made? Test Operation Pump Down Procedure When removing the productIndoor unit Packing and Unpacking GuideCushion-top  Packing case  Outdoor unit  Insulation tape Howto connectyour extended power cables021-8255 Questions or COMMENTS?183-2255 444 77 Samsung
Related manuals
Manual 50 pages 17.59 Kb