Honeywell

MK XXII EGPWS Installation Manual

Table E 3.1.6-250 Honeywell EDZ705 (5x5), EDZ756 (5x6) with DC-811 range push button control

DISPLAY CONFIGURATION GROUP 250 HONEYWELL SPZ8000, EDZ705 (5X5), EDZ756 (5X6), EDZ605, EDZ805, AND EDZ806)

Function

Display Type

Sweep Type

Auto Pop Up

Value

Honeywell (SPZ8000 new style - every fourth display line is blanked)

Honeywell

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Pop Up On Caution or Warning

Never Pop Up

Peaks Mode

Manual select

Manual deselect

Auto Range

Moving Marker

Overlay Page

Display bus type

TERRAIN DISPLAY BUS #1 453TX_1

A= J1-58

B= J1-59

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Off

Peaks On

Controlled by display system

 

Controlled by display system

 

Yes (10NM)

 

Yes (Honeywell type)

 

Yes for Peaks Elevations only.

 

Honeywell picture bus

 

CONNECT TO:

 

 

 

Terrain Display data to switching relay/Symbol Generator #1 and MFD left channel

TERRAIN DISPLAY BUS #2 453TX_2

CONNECT TO:

A= J1-56

B= J1-57

Terrain Display data to switching relay/Symbol Generator #2 and MFD right channel

CHANNEL 429_422RX_1

CONNECT TO: DC811 #1

DISPLAY INPUT CONTROL GROUP 251

1.1.1.1.1.3 Fault Designation: DISPLAY BUS 1

Bus Type: (RS-422 – 7.8125K baud)

A= J2-36

B= J2-37

CHANNEL 422RX_2

A= J2-10

B= J2-11

Data

Range (Up/Down)

CONNECT TO: DC811 #2

Data

Range (Up/Down)

Label

Sig. Bits

Range

Signal Type

Resolution

Rate (ms)

N/A

 

 

Basic

N/A

100

1.1.1.1.1.4

Fault Designation: DISPLAY BUS 2

 

 

 

 

 

 

 

 

 

BUS TYPE: (RS-422 – 7.8125K BAUD)

 

 

 

 

Label

Sig. Bits

 

Range

 

Signal Type

Resolution

 

Rate (ms)

N/A

 

 

 

 

Basic

N/A

 

100

OUTPUT 429 BUS GROUP 0

Channel

Pins

 

Comments

429TX_1 (Low Speed)

A = J2-43

B = J2-42

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x

429TX_2

A = J2-26

B = J2-9

No Connection (No Data Output)

Integration Notes:

The EGPWS ARINC 429 Output Bus must be connected to the display.

This display uses the following ARINC 429 labels from the EGPWS for annunciation: The Terrain display will annunciate:

“TERR" in green or cyan (depending on the program) when the Terrain is selected and valid. “TERR” in amber if Terrain is selected and any of the following conditions are TRUE:

The EGPWS ARINC 429 output bus is missing or labels 050 and 051 are absent or unreadable for 2 seconds.

EGPWS ARINC label 051 bit 13 = 0 (“Terrain Display Valid” bit FALSE)

EGPWS ARINC label 050 bit 17 = 1 (“Terrain Inhibit” bit TRUE)

Note - Per customer request for EDZ705 and EDZ756, the display does not go blank when Terrain is Inhibited, nor is an amber TERR presented. This change is part of the EFIS system

EGPWS ARINC labels are valid, but range in label 050 disagrees with range via SCI bus label 80 (Label 050 bits 11-14 contain the left display range and bits 15-18 contain the right).

The display will be blanked when the amber “TERR” is present.

The Terrain display will Pop Up to Terrain mode as follows:

If all the conditions indicated by for the amber “TERR” above are FALSE.

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 228

Page 228
Image 228
Honeywell MKXXII installation manual Connect to DC811 #1 Display Input Control Group, Channel 422RX2, Connect to DC811 #2