3.3.2.5 Digital –ARINC 575 (Cat. 2 ID 2)

Air Data Type 2 (ADC-80 or equivalent) is a low speed, digital ARINC 575 signal having the air data labels 203, 206, 212, and 213.

EGPWS MK XXII

J2

ARINC 575 Air Data

ARINC 575

A

39

 

 

 

 

 

 

 

 

 

Air Data Bus

B

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cat 2

 

 

 

Bus 1

Vendor Model

 

ID

 

 

A

 

B

Collins ADC-80( )

 

2

 

P3-35

 

P3-36

Collins ADC-82A

 

 

 

 

 

 

 

B&D 90004

 

2

 

J1-27

 

J1-9

AARINC 575 Bus - Hi

BARINC 575 Bus - Lo

ARINC575-ADC.vsd

Bus 2

A

B

NOTE: The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. Please contact the manufacturer’s customer service to confirm your installation.

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 64