4.4.4 WinVIEWS Operation

1.Connect the PC to the EGPWC using the RS-232 cable as described in section 4.4.2.

2.On the PC, start Windows 3.1, or higher.

3.Start the WinVIEWS.EXE program.

4.Use F6 to select the Terminal Mode. Various commands are available in this mode. Type “HELP” or “?” for a list of the commands available.

4.5 Configuration Module Programming

The EGPWC reads the aircraft configuration from the Configuration Module, which is installed in the EGPWC connector. The Configuration Module must have the aircraft specific configuration ID string written to it before the EGPWS is operational. The ID string is defined by 15 separate categories listed in Appendix E Table 5.2, Category ID Selection Procedure.

For programming the Configuration Module, the following procedure is used:

1.Verify EGPWC interface to P2 connector (including Configuration Module) and RS-232 interface to PC.

2.Power EGPWC and PC and start WinVIEWS.

3.With WinVIEWS active in the Terminal Mode, configuration sub-mode commands are available for programming purpose. Type “CFG” at the Terminal Mode prompt (>). At this point, the CFG> prompt is displayed and the program and EGPWC are ready for entering the program command and data string. Type “HELP” or “?” to display a list of the Terminal Mode commands and their description. “CUW” is the preface command for entering the ID string.

4.Using the Category ID’s as chosen from the Appendix E (refer to completed Table 5.2), create a command string with the following structure: