E 4.2.7.3 CONFIGURATION DEFINED SYNCHRO INPUTS

Quantity

Input Impedance: X leg

Input Impedance: Y leg

Input Impedance: Z leg Maximum Reverse Fault Current Input Voltage Range Reference Voltages

Accuracy

Pin Assignment (Signal Mnemonic): #1 X leg

#1 Y leg #1 Z leg #2 X leg #2 Y leg #2 Z leg #3 X leg #3 Y leg #3 Z leg

3

>140 K

>140 K

>140 K

< 200 amps

±11.8 VAC RMS ± 20% (leg to leg)

±26 VACRMS ± 20%

2.5% linearity + 0.1% full scale offset

J1-5

(SYN_3X)

J1-7

(SYN_3Y)

J1-6

(SYN_3Z)

J2-1

(SYN_4X)

J2-2

(SYN_4Y)

J2-18

(SYN_4Z)

J2-19

(SYN_5X)

J2-20

(SYN_5Y)

J2-3

(SYN_5Z)

E 4.2.8 SIGNAL TIMING REFERENCE INPUTS

These inputs accept 400 Hz AC signals, and detect the “zero crossings” of these signals. These zero crossings are used to time the conversion and input of AC signals. Absolute voltage level of these signals is not measured, but it must be within the range specified below. Voltage below the specified minimum value may result in intermittent or “jittery” zero cross detection.

Timing reference signals are required for input of most AC devices (not required for roll). These references can be brought into the appropriate timing reference input, or the system can be configured to derive a reference from the signal. Timing reference signals are specified for synchro inputs requiring a range greater than ± 80 degrees. Inputs requiring less (i.e., Roll Attitude) are configured to derive a reference from the synchro input signal and do not require a separate reference voltage input.

Quantity

2

 

Input Impedance

> 140Keach line to signal ground

Maximum Reverse Fault Current

< 120 amps

 

A/C Input Signal Frequency Range

400 Hz, ±10%

 

Maximum Input Voltage Swing (differential)

50V between input legs

Maximum Input Voltage Swing (ref. to Gnd)

50V from any leg to signal ground

Input Hardware Filtering

None

 

Minimum Input Voltage

± 0.5 VAC

 

Pin Assignment (Signal Mnemonic):

 

 

26VAC Reference #1 H

J1-4

(26REF_1H)

26VAC Reference #1 C

J1-24

(26REF_1L)

26VAC Reference #2 H

J2-34

(26REF_2H)

26VAC Reference #2 C

J2-35

(26REF_2L)

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 171