Honeywell

MK XXII EGPWS Installation Manual

Configuration Module and listed on the PC screen. Alternately, when not in the Configuration

sub-mode, the command “PS<Enter>” (Present Status) will display EGPWC and

configuration data.

7.Configuration Module programming is complete. If the “CFG >” prompt is still present type “Exit<Enter>” to exit the Configuration sub-mode.

4.5.1 CUW and CMR Comm ands

An example CUW command/data string, its definition, and the corresponding CWR list is provided

below.

CUW command/data string:

CFG > CUW 0/15 128 3 2 134 128 3 29 1 0 2 0 0 129 0 15/

Above configuration defined:

 

 

 

 

 

 

 

 

 

 

 

Category 1 Aircraft/Mode Type:

128

 

 

 

 

 

 

Category 2 Air Data Type:

 

 

 

3

 

 

 

 

 

 

Category 3 Position Type:

 

 

 

2

 

 

 

 

 

 

Category 4 Altitude Callouts Menu:

134

(All Callouts)

 

 

 

 

 

Category 5 Audio Menu:

 

 

 

128

(Basic menu)

 

 

 

 

 

Category 6 Display Type:

 

 

 

3

 

 

 

 

 

 

Category 7 Options Select Group #1:

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TA&D Alternate pop-up False)

 

 

 

 

 

 

 

 

 

(Peaks Mode True)

 

 

 

 

 

 

 

 

 

 

 

(Obstacle Awareness True)

 

 

 

 

 

 

 

 

 

 

 

(Bank Angle True)

 

 

 

 

 

 

 

 

 

 

 

(Weight on Wheels Reversal)

 

 

 

 

 

 

 

 

 

 

 

(GPS Altitude Ref. MSL)

 

 

 

Category 8 Radio Altitude Type:

1

 

 

 

 

 

 

Category 9 Navigation Type:

0

 

 

 

 

 

 

Category 10 Attitude Type:

 

 

 

2

 

 

 

 

 

 

Category 11 Heading Type:

 

 

 

0

 

 

 

 

 

 

Category 12 Windshear select Type:

0

 

 

 

 

 

 

Category 13 Discrete I/O Type:

129

 

 

 

 

 

 

Category 14 Audio Output Level Type:

0

 

 

 

 

 

 

Category 15 Autorotation Threshold

15

 

 

 

 

 

CWR list: (based on the above configuration)

 

 

 

 

 

CFG > CMR<Enter>

 

 

 

 

 

 

 

 

 

 

CONFIGURATION MODULE:

 

 

 

 

 

 

 

 

 

 

 

Format Version:

0

 

 

 

 

 

 

 

 

 

Category 1 ID:

128

 

 

 

 

 

 

 

 

Category 2 ID:

3

 

 

 

 

 

 

 

 

 

Category 3 ID:

2

 

 

 

 

 

 

 

 

 

Category 4 ID:

134

 

 

 

 

 

 

 

 

Category 5 ID:

128

 

 

 

 

 

 

 

 

Category 6 ID:

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAGE CODE:

 

SCALE: NONE

 

 

SIZE: A

 

DWG NO: 060-4314-225

 

REV: C

113

97896

 

 

 

 

 

 

 

SHEET

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 113
Image 113
Honeywell MKXXII installation manual CUW and CMR Comm ands, CFG CUW 0/15 128 3 2 134 128 3 29 1 0 2 0 0 129 0