3.3.2.2Examples

3.3.2.3Analog altitude and 500 ohm OAT

EGPWS MK XXII

 

J1

 

 

 

Uncorrected

(+)

62

Barometric

(-)

 

Altitude

43

Baro Altitude Valid +28V

9

+5V Excitation 25

(+) 63

Temp. Input

(-) 44

Chassis Ground 53

Analog Air Data Computer

Altitude Out

Signal Common

BIT Out

500ohm

Temperature

Probe

Analog-ADC.vsd

Vendor Model

CIC 04077

Collins ADS-65

CIC 02702

Honeywell AZ-241

Honeywell AZ-242

Honeywell AZ-648

Honeywell AZ-800

Honeywell AZ-810

Cat 2

ID

0

3

4

11/12

11/12

11/12

11/12

11/12

Altitude Out

J1-F

J1-12

J1-A

J1-63

J1A-40

J1-J

J1A-78

J1A-78

Uncorrected Baro Altitude

Common

BIT Out

J1-G

J1-E

J1-13

J1-5

J1-B

J1-E

J1-11

J1-12

J1A-11

J1A-12

J1-G

J1-U

J1A-10

J1A-34

J1A-10

J1A-34

NOTE: The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. Please contact the manufacturer’s customer service to confirm your installation.

NOTE: Honeywell AZ-810 should only be used as an analog source if it does not have a digital interface.

NOTE: The CIC 02702 scaling was changed in –008 software. The analog barometric altitude conversion to barometric altitude rate noise problem was fixed in –008 software.